Page 411

CHAPTER 2 ND-45670 (E)
Pag e 3 82
Revision 2.0
STEP CALL
PROGRAMMING 
DESCRIPTION DATA
Provide the system with the Step-Call feature.
Note:This feature is mutually exclusive
with the single digit feature access
code.(1)  069 (For internal Call) 
(2)  1 : Available
(1)  163 (For Tie Line Incoming Call) 
(2)  1 : Available
(1) 208 
Note 
(2)  1 : Not Available
START
END
CM08 

Page 412

ND-45670 (E) CHAPTER 2
Page 383
Revision 2.0
SUPERVISORY CONTROL OF PERIPHERAL EQUIPMENT
PROGRAMMING
DESCRIPTION DATA
Provide the Station connected to the peripher-
al equipment with momentary reversal/open 
capability.•  YY = 22
(1) X-XXXX (Station No.) 
(2)  0: To be provided 
Specify the duration of the momentary rever-
sal/open.•  Y = 1 
(1) 08
(2)  01-10: 128-1280 msec. in 128 msec. 
increments
If no data is set, the default setting is 896-1024
msec.
START
END
CM13
CM41 

Page 413

CHAPTER 2 ND-45670 (E)
Pag e 3 84
Revision 2.0
SYSTEM SPEED DIALING
PROGRAMMING
 
DESCRIPTION DATA
Assign Service Restriction Class A to each 
station. •  YY = 02
(1) X-XXXX (Station No.) 
(2) XX
 XX
*a: Service Restriction Class (A) 00-
15
Assign this service to Service Restriction 
Class A assigned by CM12 YY = 02.•  YY = 06 (System Speed Dialing) 
(1)  XX (Service Rest. Class A assigned by 
CM12 YY = 02) 
(2)  1 : To be allowed
Assign the Access Code for System Speed Di-
aling.•  Y = 0-3 (Numbering...

Page 414

ND-45670 (E) CHAPTER 2
Page 385
Revision 2.0
SYSTEM SPEED DIALING
DESCRIPTION DATA
Assign the memory block for System Speed 
Dialing. 300 memory slots are available per 
system. The number of slots available for each 
Tenant is also 300. Note that the memory 
blocks for Hot Line-Outside and Route Ad-
vance (from Tie Line to C.O. Line) are includ-
ed in 300 memory slots.
Abbreviated Call Codes required for access-
ing this feature are automatically given to each 
Tenant as shown in the following example....

Page 415

CHAPTER 2 ND-45670 (E)
Pag e 3 86
Revision 2.0
SYSTEM SPEED DIALING
To use the 1000 Slot Memory Block Number (0-3) for Station Speed Dialing as the Memory Block for System Speed
Dialing, add the following programming.
DESCRIPTION DATA
Specify the 1000-Slot Memory Block Number 
0-3.(1)  112: 1000-Slot Memory Block No.0 
(2)  0/1 : Available/Not Available
(1)  111: 1000-Slot Memory Block No.1 
(2)  0/1 : Available/Not Available
(1)  176: 1000-Slot Memory Block No.2 
(2)  0/1 : Available/Not Available
(1)...

Page 416

ND-45670 (E) CHAPTER 2
Page 387
Revision 2.0
SYSTEM SPEED DIALING
DESCRIPTION DATA
Assign the stored number to each Memory 
Slot Number.(1) X XXX (Memory Slot No.) 
*a: 1000-Slot Memory Block Number 
(0-3)
*b: 000-999 
(2)  Stored No. (Max. 16/26 digits) Setting
Method: Outgoing Call Access Code 
(Max.2 digits) +   + Stored 
No. (Max. 16/26 digits) 
To set a pause into the stored No., enter “C” 
(Fixed Pause = 1.5 sec) or “D” (Programma-
ble Pause specified by CM41-38) after desired 
digits.CM74
A
END
*a...

Page 417

CHAPTER 2 ND-45670 (E)
Pag e 3 88
Revision 2.0
TENANT SERVICE
PROGRAMMING 
DESCRIPTION DATA
Assign a Tenant No. to each station. •  YY = 04
(1) X-XXXX (Station No.) 
(2)  00 -63 (Tenant No.) 
Assign a Tenant No. to each trunk. •  YY = 01
(1) 000-255 (Trunk No.) 
(2)  00 -63 (Tenant No.) 
Assign a Numbering Plan Group No. to each 
Tenant. (1)  00-63 (Tenant No.) 
(2)  710-713 (Numbering Plan Group 0-3) 
Assign the required access codes for each 
Numbering Plan Group. To provide a trunk 
route for each...

Page 418

ND-45670 (E) CHAPTER 2
Page 389
Revision 2.0
TENANT SERVICE
DESCRIPTION DATA
To provide external keys for the Day/Night 
mode changeover or the Class of Service 
changeover, assign a Tenant No. to each cir-
cuit No. on the PN-DK00 card. •  YY = 00 
(1) XX
 X 
*a: Card No. (00-63) for PN-DK00 as-
signed by CM10 (E900-E963) 
*b: Circuit No. (0-7) 
(2)  00-63 (Tenant No.) 
Specify the Tenants to be handled by each 
SN610 ATTCON Group. •  Y = 0-3 (ATTCON Group 0-3 assigned 
by CM60 YY = 00) 
(1)  00-63...

Page 419

CHAPTER 2 ND-45670 (E)
Pag e 3 90
Revision 2.0
TIE LINE TANDEM SWITCHING
PROGRAMMING 
HARDWARE REQUIRED 
Tie Line Trunk Card (PN-2ODT) 
DESCRIPTION DATA
Specify the combination of Trunk Routes al-
lowing the Tandem connection. The incoming 
trunk route must provide a release signal for 
the Tandem Connection. (See CM35 YY = 05) (1) XX XX
*a: 00-63 (Incoming Trunk Route) 
*b: 00-63 (Outgoing Trunk Route) 
(2)  0/1 : Allowed/Restricted
START
END
CM36*a *b 

Page 420

ND-45670 (E) CHAPTER 2
Page 391
Revision 2.0
TIMED QUEUE
PROGRAMMING
HARDWARE REQUIRED
ETJ-8-1/ETJ-10DC-1/ETJ-16DD-1/ETJ-24DS-1 and PN-2DLCB/PN-4DLCA card.
DESCRIPTION DATA
Specify the timer data for this feature.
If no data is set, the following data is applied:
• Number of Call Attempts: 3 times
• Interval Time of Call Attempt: 120 sec. -
124 sec.
• Duration of Calling: 28 sec. -32 sec.•  Y = 0
(1)  35 (Number of Times of Call Attempt)
(2)  01-07: Once-7 times
 
(1)  36 (Interval time of Call Attempt)...