NEC Neax2000 Ivs Feature Programming Manual
Here you can view all the pages of manual NEC Neax2000 Ivs Feature Programming Manual. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 411
CHAPTER 2 ND-45670 (E) Pag e 3 82 Revision 2.0 STEP CALL PROGRAMMING DESCRIPTION DATA Provide the system with the Step-Call feature. Note:This feature is mutually exclusive with the single digit feature access code.(1) 069 (For internal Call) (2) 1 : Available (1) 163 (For Tie Line Incoming Call) (2) 1 : Available (1) 208 Note (2) 1 : Not Available START END CM08
Page 412
ND-45670 (E) CHAPTER 2 Page 383 Revision 2.0 SUPERVISORY CONTROL OF PERIPHERAL EQUIPMENT PROGRAMMING DESCRIPTION DATA Provide the Station connected to the peripher- al equipment with momentary reversal/open capability.• YY = 22 (1) X-XXXX (Station No.) (2) 0: To be provided Specify the duration of the momentary rever- sal/open.• Y = 1 (1) 08 (2) 01-10: 128-1280 msec. in 128 msec. increments If no data is set, the default setting is 896-1024 msec. START END CM13 CM41
Page 413
CHAPTER 2 ND-45670 (E) Pag e 3 84 Revision 2.0 SYSTEM SPEED DIALING PROGRAMMING DESCRIPTION DATA Assign Service Restriction Class A to each station. • YY = 02 (1) X-XXXX (Station No.) (2) XX XX *a: Service Restriction Class (A) 00- 15 Assign this service to Service Restriction Class A assigned by CM12 YY = 02.• YY = 06 (System Speed Dialing) (1) XX (Service Rest. Class A assigned by CM12 YY = 02) (2) 1 : To be allowed Assign the Access Code for System Speed Di- aling.• Y = 0-3 (Numbering...
Page 414
ND-45670 (E) CHAPTER 2 Page 385 Revision 2.0 SYSTEM SPEED DIALING DESCRIPTION DATA Assign the memory block for System Speed Dialing. 300 memory slots are available per system. The number of slots available for each Tenant is also 300. Note that the memory blocks for Hot Line-Outside and Route Ad- vance (from Tie Line to C.O. Line) are includ- ed in 300 memory slots. Abbreviated Call Codes required for access- ing this feature are automatically given to each Tenant as shown in the following example....
Page 415
CHAPTER 2 ND-45670 (E) Pag e 3 86 Revision 2.0 SYSTEM SPEED DIALING To use the 1000 Slot Memory Block Number (0-3) for Station Speed Dialing as the Memory Block for System Speed Dialing, add the following programming. DESCRIPTION DATA Specify the 1000-Slot Memory Block Number 0-3.(1) 112: 1000-Slot Memory Block No.0 (2) 0/1 : Available/Not Available (1) 111: 1000-Slot Memory Block No.1 (2) 0/1 : Available/Not Available (1) 176: 1000-Slot Memory Block No.2 (2) 0/1 : Available/Not Available (1)...
Page 416
ND-45670 (E) CHAPTER 2 Page 387 Revision 2.0 SYSTEM SPEED DIALING DESCRIPTION DATA Assign the stored number to each Memory Slot Number.(1) X XXX (Memory Slot No.) *a: 1000-Slot Memory Block Number (0-3) *b: 000-999 (2) Stored No. (Max. 16/26 digits) Setting Method: Outgoing Call Access Code (Max.2 digits) + + Stored No. (Max. 16/26 digits) To set a pause into the stored No., enter “C” (Fixed Pause = 1.5 sec) or “D” (Programma- ble Pause specified by CM41-38) after desired digits.CM74 A END *a...
Page 417
CHAPTER 2 ND-45670 (E) Pag e 3 88 Revision 2.0 TENANT SERVICE PROGRAMMING DESCRIPTION DATA Assign a Tenant No. to each station. • YY = 04 (1) X-XXXX (Station No.) (2) 00 -63 (Tenant No.) Assign a Tenant No. to each trunk. • YY = 01 (1) 000-255 (Trunk No.) (2) 00 -63 (Tenant No.) Assign a Numbering Plan Group No. to each Tenant. (1) 00-63 (Tenant No.) (2) 710-713 (Numbering Plan Group 0-3) Assign the required access codes for each Numbering Plan Group. To provide a trunk route for each...
Page 418
ND-45670 (E) CHAPTER 2 Page 389 Revision 2.0 TENANT SERVICE DESCRIPTION DATA To provide external keys for the Day/Night mode changeover or the Class of Service changeover, assign a Tenant No. to each cir- cuit No. on the PN-DK00 card. • YY = 00 (1) XX X *a: Card No. (00-63) for PN-DK00 as- signed by CM10 (E900-E963) *b: Circuit No. (0-7) (2) 00-63 (Tenant No.) Specify the Tenants to be handled by each SN610 ATTCON Group. • Y = 0-3 (ATTCON Group 0-3 assigned by CM60 YY = 00) (1) 00-63...
Page 419
CHAPTER 2 ND-45670 (E) Pag e 3 90 Revision 2.0 TIE LINE TANDEM SWITCHING PROGRAMMING HARDWARE REQUIRED Tie Line Trunk Card (PN-2ODT) DESCRIPTION DATA Specify the combination of Trunk Routes al- lowing the Tandem connection. The incoming trunk route must provide a release signal for the Tandem Connection. (See CM35 YY = 05) (1) XX XX *a: 00-63 (Incoming Trunk Route) *b: 00-63 (Outgoing Trunk Route) (2) 0/1 : Allowed/Restricted START END CM36*a *b
Page 420
ND-45670 (E) CHAPTER 2 Page 391 Revision 2.0 TIMED QUEUE PROGRAMMING HARDWARE REQUIRED ETJ-8-1/ETJ-10DC-1/ETJ-16DD-1/ETJ-24DS-1 and PN-2DLCB/PN-4DLCA card. DESCRIPTION DATA Specify the timer data for this feature. If no data is set, the following data is applied: • Number of Call Attempts: 3 times • Interval Time of Call Attempt: 120 sec. - 124 sec. • Duration of Calling: 28 sec. -32 sec.• Y = 0 (1) 35 (Number of Times of Call Attempt) (2) 01-07: Once-7 times (1) 36 (Interval time of Call Attempt)...