CHAPTER 2 ND-45670 (E)
Pag e 4 38
Revision 2.0
DATA HUNTING
PROGRAMMING
In addition to the programming of Asynchronous/Synchronous Data Switching, do the following programming to
the required Data Stations.
To assign Station Hunting-Circular:
DESCRIPTION DATA
To set up each Hunting Group, assign data sta-
tion numbers, one by one, in order of the Hunt-
ing as shown below.
Example:
  For Setting Data Station Number 
200, 201, 202 into one Hunting 
Group.• Y = 0
(1)  X-XXXX (Data Station No. to be includ-...

Page 472

ND-45670 (E) CHAPTER 2
Page 439
Revision 2.0
DATA HUNTING
To assign Station Hunting-Terminal:
DESCRIPTION DATA
To set up each Hunting Group, assign data sta-
tion numbers, one by one, as shown below.•  Y = 0
(1)  X-XXXX (Data Station No. to be includ-
ed in the Hunting Group)
(2)  X-XXXX (Another Data Station No. to 
be included in the Same Hunting Group.)
Assign the Pilot Station to required data sta-
tion number within the Hunting Group.
For the Member Data Stations, set the data to 
“0”.
Note:The...

Page 473

CHAPTER 2 ND-45670 (E)
Pag e 4 40
Revision 2.0
DATA INTERFACE-AUTOMATIC ANSWER
PROGRAMMING
DESCRIPTION DATA
Assign the Data Interface-Automatic Answer 
key to a line key on the Multiline Terminal.•  YY = 00 
(1)  Primary Extension Number +   + Key 
No. 
(2) F2001: 
or
F2003: 
Assign the attribute data for each data 
terminal.• YY = 01 (Automatic Answer)
(1)X-XXXX (Data Station No.)
(2) 0 : Automatic Answer
1 : Manual/Automatic Answer (Se-
lectable by   / 
)CM90 START
END
CMA1,
AUTO/DISP
AU TO
AUTO/DISP...

Page 474

ND-45670 (E) CHAPTER 2
Page 441
Revision 2.0
DO NOT DISTURB-DATA LINE
PROGRAMMING
To provide Do Not Disturb-Data Line key to the required data stations:
DESCRIPTION DATA
Assign the Do Not Disturb-Data Line key to a 
line key on the Multiline Terminal.•  YY = 00 
(1)  Primary Extension No. +   + Key No. 
(2) F2005: CM90 START
END
,
DATA DND 

Page 475

CHAPTER 2 ND-45670 (E)
Pag e 4 42
Revision 2.0
NAILED-DOWN CONNECTION
PROGRAMMING
In addition to the programming of Asynchronous/Synchronous Data Switching, do the following programming to
the required data stations.
DESCRIPTION DATA
Specify the connecting digital trunks in inter-
office digital data transmission via DDI/CCIS.•  YY = 92 
(1)  Trunk Route Number 
(2)  0 : 48 kbps (Digital Data)
1 : 56 kbps (Digital Data)
2 : 64 kbps (Transparent Digital Data)
7 : Analog Data (Modem)
Assign Nailed-Down...

Page 476

ND-45670 (E) CHAPTER 2
Page 443
Revision 2.0
SYNCHRONOUS DATA SWITCHING
PROGRAMMING
DESCRIPTION DATA
Assign a Data Station Number to the Primary 
Extension Number (assigned by CM10) of the 
Multiline Terminal equipped with a Data 
Adapter.(1)  Primary Extension No. (X-XXXX)
(2)  Data Station No. (X-XXXX)
Specify the Data Station Number length. • Y = 0-3 (Numbering Plan Group 0-3)
(1) Leading one/two/three digits of Data Sta-
tion No.
(2) 801: Single Digit
802: 2 digits
803: 3 digits
804: 4 digits
Assign...

Page 477

CHAPTER 2 ND-45670 (E)
Pag e 4 44
Revision 2.0
SYNCHRONOUS DATA SWITCHING
DESCRIPTION DATA
Set up detection of DTR signal from the Data 
Terminal.•  YY = 00 
(1) Data Station Number
(2)  0 :  Not to be detected
1 :  To be detected
Select Automatic Answer. • YY = 01 
(1) Data Station Number
(2)  0 : Automatic answer
1 : Manual answer
Determine Data Speed. • YY = 04
(1) Data Station Number
(2) 07 : 1200 bps
08 : 2400 bps
09 : 4800 bps
10 : 9600 bps
11 : 19.2 Kbps
12 : 48 Kbps
13 : 56 Kbps
31 : 1200 bps...

Page 478

ND-45670 (E) CHAPTER 2
Page 445
Revision 2.0
SYNCHRONOUS DATA SWITCHING
HARDWARE REQUIRED
ETJ-8-1/ETJ-16DC-1/ETJ-16DD-1/ETJ-24DS-1 and PN-2DLCB/4DLCA card
SN1152 DTAM-A Data Adapter 
DTE
DESCRIPTION DATA
Assign Character Code. • YY = 09 
(1) Data Station Number
(2)  00 : ASCII (7 bit) + even parity
01 : ASCII (7 bit) + odd parity
02 : ASCII (7bit) + parity (0)
03 : ASCII (7bit) + parity (1)
04 : JIS (7bit) + even parity
05 :  JIS (7bit) + odd parity
06 :  JIS (8 bit)
07 : EBCDIC (8 bit)
15 : Non...

Page 479

CHAPTER 2 ND-45670 (E)
Pag e 4 46
Revision 2.0
TERMINAL ATTRIBUTE DATA ASSIGNMENT
PROGRAMMING
DESCRIPTION DATA
Assign the function keys on the Multiline Ter-
minal.•  YY = 00 
(1)  Primary Extension No. +   + Key No.
(2) F2000: 
F2002:  CM90 START
END
,
DATA