Home > NEC > Communications System > NEC Neax2000 Ivs Command Manual

NEC Neax2000 Ivs Command Manual

Here you can view all the pages of manual NEC Neax2000 Ivs Command Manual. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 401

CHAPTER 3 ND-45669 (E)
Pag e 3 58
Revision 2.0
CMEA
COMMAND CODE
TITLE:
FAULT INFORMATION STORE/DISPLAY FUNCTIONS
EA
MAT
: Initial Kind (Upper digit)
1: Program address information
2: Receive command information
F: No system initialized related information
: Initial Kind (Lower digit)
0: Power On Initialize
1: Initialize by Reset key
2: Major Alarm 1
3: Major Alarm 2
4: Not Used
5: Major Alarm 3
6: Major Alarm 4
7: Major Alarm 5
8: Major Alarm 6
9: Initialize by SENS SW selection
A: Major Alarm 7
B:...

Page 402

ND-45669 (E) CHAPTER 3
Pag e 3 59
Revision 2.0
CMEA
COMMAND CODE
TITLE:
FAULT INFORMATION STORE/DISPLAY FUNCTIONS
EA
MAT
: System Initialization related information
The address of the program which caused system initialization. Note that, when the program which
caused initialization is lpdi, the receive command (4 bytes from the head) is stored. This informa-
tion is output in the case of system initialization only when the initial kind in 14 is 02, 03, 06, or
0A.
: Stack Kind (Lower digit)
0: The number...

Page 403

CHAPTER 3 ND-45669 (E)
Pag e 3 60
Revision 2.0
CMEA
COMMAND CODE
TITLE:
FAULT INFORMATION STORE/DISPLAY FUNCTIONS
EA
MAT
A: Not used
B: Not used
C: Not used
D: Not used
E: Not used
F: Not used
: D-channel circuit No.
• DCH:  00=Channel No. 0
: CCH No.
0–3:  CCH No.
: DLC Failure Kind
00: Terminal was cut off
02: Short circuit was made on the line
03: A wire was grounded
04: B wire was grounded or terminal was unconnected
05: Terminal failure
08: Terminal circuit failure
: LEN (0000-0511)
: Station No....

Page 404

ND-45669 (E) CHAPTER 3
Pag e 3 61
Revision 2.0
CMEC
COMMAND CODE
TITLE:
BATTERY RELEASE/LINE STATUS DISPLAY
EC
4. DATA TABLE:
1. FUNCTION:
This command is used for maintenance of the PBX. The functions of this command are outlined below:
•  Battery release
•  Line status display for single line telephone or Multiline Terminal
2. PRECAUTION:
(1) See Line Status Display in the following pages for details on how to read the status information.
(2) Line status display of a single line should not be performed...

Page 405

CHAPTER 3 ND-45669 (E)
Pag e 3 62
Revision 2.0
CMEC
COMMAND CODE
TITLE:
BATTERY RELEASE/LINE STATUS DISPLAY
EC
n  Line Status Display
Operation : 
Explanation of Screen Information:
(a)  Station Number : X-XXXX (1-4 digits)
(b) Analog Line/Digital Line
00: LC (Single Line Tel.)
10: DLC (Multiline Terminal)
(c) Hardware Test
(d) Software Test
01: Idle
02: Line Lockout
Other than 01, 02: Busy
INDICATION STATUS OF SINGLE LINE TEL.STATUS OF MULTILINE 
TERMINALREMARKS
00 Terminal is not connected Terminal is...

Page 406

ND-45669 (E) CHAPTER 3
Pag e 3 63
Revision 2.0
CMEE
COMMAND CODE
TITLE:
VIRTUAL TIE LINE SET/RELEASE
EE
4. DATA TABLE:
1. FUNCTION:
This command sets/releases the virtual tie line (Event Based CCIS) from a MAT.
2. PRECAUTION:
None
3. ASSIGNMENT PROCEDURE:
 + EEY +   +   +   +   + 
: Initial Data
Y Y 1S T DATA 2ND DATA
RELATED 
COMMAND
No. MEANING DATA MEANING DATA MEANING
1 Virtual tie line set/
releaseXXXX Trunk No. of oppo-
site office assigned 
by CM30 YY = 190
1Set
ReleaseCM30 YY = 19
STDE1ST DATA...

Page 407

CHAPTER 3 ND-45669 (E)
Pag e 3 64
Revision 2.0
CME1, F0, F1
COMMAND CODE
TITLE:
SPECIAL COMMANDS
E1, F0, F1
1. FUNCTION:
These commands are used only for maintenance. DO NOT USE these commands without the assistance of
a NEC engineer.
(1) MP Memory Check Sum Display (CME1 Y=0)
The following shows the steps for displaying check sums using the CAT
Note 1:XX: 01-04 (MP Memory Area Number)
Note 2:YYYY: 0000-FFFF (Check Sum)
(2) MP Memory Dump (CMF0)
The following shows the steps for performing a memory read...

Page 408

ND-45669 (E) CHAPTER 3
Pag e 3 65
Revision 2.0
CMF2, F3
COMMAND CODE
TITLE:
SPECIAL COMMANDS
F2, F3
(4) FP Memory Dump (CMF2)
The following shows the steps for performing a memory read using the CAT.
Note 1:Y: 0-F (FP Number)
Note 2:Z: 0-F (Segment)
Note 3:XXXX: 0000-FFFF(Address)
Note 4:YY: 00-FF (Data)
(5) FP Memory Read/Write (CMF3)Note 1
The following shows the steps for changing memory using the CAT.
Note 1:Use Extreme care when using this command while the system is in service.
Note 2:Y: 0-F (FP...

Page 409

CHAPTER 3 ND-45669 (E)
Pag e 3 66
Revision 2.0
CMF5
COMMAND CODE
TITLE:
SPECIAL COMMANDS
F5
(6) Line/Trunk Memory/Alarm Memory Read (CMF5)
The following shows the steps for performing a memory read using the MAT/CAT.
Y1ST DATAREADOUT DATA
(STATUS INFORMATION)REMARKS
0X
XXXXSingle Line Station/Virtual Line Station 
Number (1-4 digits) X=0-9, A(*), B(#)Status of Station/Trunk
FX
FXXXXMultiline Terminal Number  
represents Primary Extension Number
D000
D255Trunk Number
2X
XXXXSingle Line Station/Virtual...

Page 410

ND-45669 (E) CHAPTER 3
Pag e 3 67
Revision 2.0
CMF5
COMMAND CODE
TITLE:
SPECIAL COMMANDS
F5
Note 1:A status information associated with Y = 0, 3 will be displayed as shown below.
For the meaning of the status information displayed, refer to the Maintenance Manual.
Note 2:Status information associated with Y = 2 will be displayed as shown below:
Display F52 > X - XXXX : YYYY - /ZZZZ -
or
F52 > FX - FXXXX: YYYY -
or
F52 > D000 - D255 : YYYY -
YYYY : 0000 - 0511 (LEN)
ZZZZ : 0000 - 0255 (Virtual LEN)...