Page 441

CHAPTER 3 ND-45669 (E)
Page 398 Addendum-002
Revision 2.2 JANUARY, 1999
CMD016
COMMAND CODE
TITLE:
STATION FEATURES
D016
4 . D ATA  TA B L E :
1. FUNCTION:
This command assigns the class functions for each class assigned by CMD015.
2. PRECAUTION:
None
3. ASSIGNMENT PROCEDURE:
: Initial Data
1ST DATA
2ND DATA
DATA MEANING
XX05 Room status code sending to the PMS 0  : Not sent
1: Send
XX06 Room status processing is executed by operations on Front Desk Terminal 0  : No
1: Yes
XX07 Message Waiting,...

Page 442

ND-45669 (E) CHAPTER 3
Addendum-002 Page 399
JANUARY, 1999 Revision 2.2
CMD016
COMMAND CODE
TITLE:
STATION FEATURES
D016
XX32 Send call information for Tie Line outgoing calls through CCIS 0  : Not sent
1: Send
XX42 Message Waiting Message sending to PMS 0  : Available
1: Not available
XX43 Control of Restriction Message sending to PMS 0  : Available
1: Not available
XX44 Wake-up Message sending to PMS 0  : Available
1: Not available
XX45 Assignment the Administrative Station 0  : Not available
1:...

Page 443

CHAPTER 3 ND-45669 (E)
Pag e 4 00
Revision 2.0
CMD026
COMMAND CODE
TITLE:
ROUTE INDEX FOR CALL CHARGE DEVELOPMENT
D026
4. DATA TABLE:
• For each Table Number assigned by this command, the charging method for each dialed digit is
assigned by CMD027 as shown below.
1. FUNCTION:
This command is used to assign a Development Table Number for each outgoing trunk route.
2. PRECAUTION:
Although actual charging is not determined by the PBX, it is necessary to program this command and
CMD027 to get SMDR output.
3....

Page 444

ND-45669 (E) CHAPTER 3
Pag e 4 01
Revision 2.0
CMD027
COMMAND CODE
TITLE:
CALL CHARGE DEVELOPMENT TABLES
D027
4. DATA TABLE:
Note:The actual digits sent from a trunk should be assigned.
1. FUNCTION:
This command is used for assigning the charging method to each dialled digit on the basis of each Devel-
opment Table designated by CMD026.
2. PRECAUTION:
None
3. ASSIGNMENT PROCEDURE:
: Initial Data
1S T DATA 2ND DATA
XXX
 X
Dialed digit (0 - 9, A(*), B(#)) Note
Development Table No. (000 - 255)1 : Do not...

Page 445

CHAPTER 3 ND-45669 (E)
Pag e 4 02
Revision 2.0
CMD031
COMMAND CODE
TITLE:
ROOM STATUS CODE
D031
4. DATA TABLE:
X: Room Status Code to be set.
1. FUNCTION:
This command is used to assign the desired functions for each Room Status Code which is dialed from a
guest room or a Front Desk Terminal
2. PRECAUTION:
None
3. ASSIGNMENT PROCEDURE:
: Initial Data
1ST DATA (X: ROOM STATUS CODE 1 - 8)
2ND DATA
DATA FUNCTION
X00 Room Cutoff set. 0 : No
1:Yes
X01 Room Cutoff is cancelled.
X02 Do Not Disturb is set.
X03...

Page 446

ND-45669 (E) CHAPTER 3
Pag e 4 03
Revision 2.0
CMD031
COMMAND CODE
TITLE:
ROOM STATUS CODE
D031
Example:The table below shows the examples of functions by this command. 
Note:
The Room Status Codes for Check In and Check Out are to be assigned by means of CMD001 – 12 and – 13.
ROOM STATUS CODEFUNCTION NUMBER
00 01 02 03 04 05 06 07 08 31
1Check In (Note) / ////
2Check Out (Note)/ // /
3 Under Cleaning / / / /
4 Cleaning Finished / / / / /
5Check Finished /////
6Out of Service / ////
7
8 

Page 447

CHAPTER 3 ND-45669 (E)
Pag e 4 04
Revision 2.0
CMD033
COMMAND CODE
TITLE:
ROUTE INDEX FOR CALL DEVELOPMENT
D033
4. DATA TABLE:
On the basis of each Table Number assigned by this command, the type of call to the dialed digits is
assigned by CMD034 as shown below.
1. FUNCTION:
This command is used to assign a Type of Call Identifying Development Table for each outgoing trunk
route.
2. PRECAUTION:
Although the type of Call Identifier has no meaning for the U.S. market, this command and CMD034
must be...

Page 448

ND-45669 (E) CHAPTER 3
Pag e 4 05
Revision 2.0
CMD034
COMMAND CODE
TITLE:
CALL DEVELOPMENT TABLES
D034
4. DATA TABLE:
Note 1:The actual digits sent from a trunk should be assigned.
Note 2:This feature restricts Toll Call and International Call. (Type of Call No. 2 and No. 3 assigned by
this command.)
1. FUNCTION:
This command is used to assign Type of Call to the dialed digits on each Type of Call Identifying Table
Number assigned by CMD033.
2. PRECAUTION:
None
3. ASSIGNMENT PROCEDURE:
: Initial Data
1ST...

Page 449

CHAPTER 3 ND-45669 (E)
Pag e 4 06
Revision 2.0
CMD034
COMMAND CODE
TITLE:
CALL DEVELOPMENT TABLES
D034
Example:Call Development Tables are assigned according to the following table.
Trunk Route
to set: Route 0
ACCESS
CODE = 0Command D033
ROUTE 0Command D034
ISD Call (000)
Toll Call (01 - 09)
Local Call (2 - 9)
DIGIT TYPE OF CALL
00
01
09
2
9ISD Call
Toll Call
Local Call
• CMD033
To Trunk Route 0, assign No. 0 Call
Development Table.
• CMD034
In No. 0 Call Development Table;
1. Set No. 1 Call Development...

Page 450

ND-45669 (E) CHAPTER 3
Pag e 4 07
Revision 2.0
CMD035
COMMAND CODE
TITLE:
DESIGNATION OF PRINTER
D035
4. DATA TABLE:
1. FUNCTION:
This command is used to designate the printer for printout by key operation at each Front Desk Instru-
ment.
2. PRECAUTION:
None
3. ASSIGNMENT PROCEDURE:
: Initial Data
1ST DATA
2ND DATA
DATA FUNCTION
X
XXXXFront Desk Instrument (Multiline Terminal) Primary Extension 
Number assigned by CM 10 (FX - FXXXX).0:Printer 0
1:Printer 1
ST   +   D035   +   DE   +1ST DATA
(1 - 4...
Start reading NEC Neax2000 Ivs Command Manual