NEC Neax2000 Ivs Command Manual
Here you can view all the pages of manual NEC Neax2000 Ivs Command Manual. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 391
CHAPTER 3 ND-45669 (E) Page 348 Addendum-002 Revision 2.2 JANUARY, 1999 CME5 COMMAND CODE TITLE: STATION, TRUNK LINE MAKE BUSY E5 4. DATA TABLE: Note 1:For a station that is made busy, call termination to the station is restricted, but Call origination is available. For extension lines on a Multiline Terminal, My Line and Multiline make busy can be set individually, with the same condition as mentioned above. Note 2:For a trunk that is made busy, the outgoing call is restricted, but on incoming, the call...
Page 392
ND-45669 (E) CHAPTER 3 Addendum-002 Page 349 JANUARY, 1999 Revision 2.2 CME6 COMMAND CODE TITLE: CALL FORWARDING SET/RESET FROM MAT/CAT E6 4. DATA TABLE: Note:To reset Call Forwarding, assign “CCC” to the second data. 1. FUNCTION: This command sets/resets the Call Forwarding service to each station from a MAT/CAT. 2. PRECAUTION: CME6 can be used for any station irrespective of its state. 3. ASSIGNMENT PROCEDURE: + E6YY + + + + + YY MEANING DESTINATION No. 00 Call Forwarding-All Calls •...
Page 393
CHAPTER 3 ND-45669 (E) Pag e 3 50 Revision 2.0 CME7 COMMAND CODE TITLE: PASSWORD LEVEL E7 4. DATA TABLE: Note:In case of YY = 20, 21, the data to be set is “1” only. 1. FUNCTION: This command specifies the accessible commands for each Password Level. 2. PRECAUTION: None 3. ASSIGNMENT PROCEDURE: : Initial Data YY COMMAND CODE SETTING DATA No. PASSWORD LEVEL 00 01 02 03 04 05 06 10 11 12 13 14 15 16Password Level 0 – 6 1 – 6 2 – 6 3 – 6 4 – 6 5 – 6 6 0 1 2 3 4 5 6XX: 00 – FF (Exclusive of 03, E7, E9)0:...
Page 394
ND-45669 (E) CHAPTER 3 Pag e 3 51 Revision 2.0 CME9 COMMAND CODE TITLE: PASSWORD CODE E9 MAT 4. DATA TABLE: Note:Password Level 7 can access all the commands. 1. FUNCTION: This command is used to define the Password Code of each Password Level and the availability of Pass- word Service. 2. PRECAUTION: (1) Before setting the Password code, Function Number 8 (Change of Password) must be set to 0 (Allowed). (2) When programming a Password Code, the Password Code for Password Level 7 must be made. If no...
Page 395
CHAPTER 3 ND-45669 (E) C M EA M AT 1. FUN CTIO N: ST + E AY + DE + [ C M EA ] Fau lt I nf orm ation Store /D isp lay F unct io n s
Page 398
ND-45669 (E) CHAPTER 3 Pag e 3 55 Revision 2.0 CMEA COMMAND CODE TITLE: FAULT INFORMATION STORE/DISPLAY FUNCTIONS EA MAT n Fault Information Display After the following operation: The first screen displays on the MAT/CAT. The fault information is separated into four separate parts, and displayed on four screens. An example of fault information display is provided below: EXPLANATION OF SCREEN INFORMATION 1: Fault Occurrence Kind No./Fault Restoration Kind No. FAULT KIND NUMBERFAULT...
Page 399
CHAPTER 3 ND-45669 (E) Pag e 3 56 Revision 2.0 CMEA COMMAND CODE TITLE: FAULT INFORMATION STORE/DISPLAY FUNCTIONS EA MAT EXPLANATION OF SCREEN INFORMATION (Continued) 2: External Alarm Kind (MJ/MN/-) Use of External Alarm Kind - Minor (MN), Major (MJ) or external alarm is not provided (-) can be programmed by CMEA Y=2. The following table shows the standard data set by the 2nd data = 3 of CMEA Y=2. FAULT RESTORATION KIND NUMBERFAULT RESTORATION CONTENT 18 FP/AP package returned to normal condition 19...
Page 400
ND-45669 (E) CHAPTER 3 Pag e 3 57 Revision 2.0 CMEA COMMAND CODE TITLE: FAULT INFORMATION STORE/DISPLAY FUNCTIONS EA MAT EXPLANATION OF SCREEN INFORMATION (Continued) 3: CPU Kind and FP/AP number for which a fault was detected 4: Date and Time of Fault Occurrence and Restoration 5-12: Fault-Related Information/Fault Restoration-Related Information INDICATION MEANING MP 00 MP FP 00 - 03 FP Number 0 - 3 AP 04 - 15 AP Card Number 4 - 15 FAU LT KIND NUMBER56789101112 01 Initial Kind, etc 1 , 2System...