CMA0
COMMAND CODE
TITLE:
TYPE OF DATA ADAPTER
A0
MAT
4. DATA TABLE:
1. FUNCTION:
This command is used to specify the type of Data Adapter used for accommodating a Data Terminal to
the data station.
2. PRECAUTION:
This command is included in MAT mode menu “E5” (Data Station Attribute [COM02]).
3. ASSIGNMENT PROCEDURE:
: Initial Data
DATA STATION
NUMBER (STA NO.)SETTING DATA (TYPE)
RELATED
COMMAND
DATA MEANING (TYPE OF DATA ADAPTER)
X
XXXX02 SN1152 DTAM – A...

Page 352

ND-45669 (E) CHAPTER 3
Pag e 3 13
Revision 2.0
CMA1
COMMAND CODE
TITLE:
DATA TERMINAL ATTRIBUTE DATA
A1
MAT
4. DATA TABLE:
1. FUNCTION:
This command is used to define the attribute data (terminal characteristics data for data communications)
of each data terminal.
2. PRECAUTION:
This command is included in MAT mode menu “E5” (Data Station Attribute [COM02]).
3. ASSIGNMENT PROCEDURE:
: Initial Data
YY SETTING DATA
RELATED
COMMAND
No. MEANING DATA MEANING
00
(ER)Detection of ER (DTR) signal 
from Data...

Page 353

CHAPTER 3 ND-45669 (E)
Pag e 3 14
Revision 2.0
CMA1
COMMAND CODE
TITLE:
DATA TERMINAL ATTRIBUTE DATA
A1
MAT
04
(SPEED)Data Speed 00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17–3150 bps
75 bps
110 bps
150 bps
200 bps
300 bps
600 bps
1200 bps
2400 bps
4800 bps
9600 bps
19.2 Kbps
48 Kbps
56 Kbps
64 Kbps
7200 bps
14.4 Kbps
1200 bps
05
(PRTY)Parity Check 0
1Effective
Ineffective
06
(SYNC)Synchronous/Asynchronous 0
1
2
3
7Synchronous Transmission by In-
ternal Clock (PBX Clock)
Synchronous Transmission...

Page 354

ND-45669 (E) CHAPTER 3
Pag e 3 15
Revision 2.0
CMA1
COMMAND CODE
TITLE:
DATA TERMINAL ATTRIBUTE DATA
A1
MAT
09
(CHR)Type of Code 00
01
02
03
04
05
06
07
15ASCII (7-bit) + even parity
ASCII (7-bit) + odd parity
ASCII (7-bit) + parity (0)
ASCII (7-bit) + parity (1)
JIS (7-bit) + even parity
JIS (7-bit) + odd parity
JIS (8-bit)
EBCDIC (8-bit)
Non character (Binary Data)
11
(HOTL)Hot Line Data Station 0
1Hot Line Data Station 
(Calling Side)
Ordinary Data StationCM52
12
(HOTC)Hot Line connection 0
1By “DATA”...

Page 355

CHAPTER 3 ND-45669 (E)
Pag e 3 16
Revision 2.0
CMA5
COMMAND CODE
TITLE:
NAILED DOWN CONNECTION
A5
4. DATA TABLE:
1. FUNCTION:
This command is used to define a nailed-down connection, which provides a fixed connection between
data stations, data station and DTI (Digital Trunk Interface) or DTIs.
2. PRECAUTION:
None
3. ASSIGNMENT PROCEDURE:
YYSETTING DATA
DATA STATION NUMBER (A) / 
TRUNK NUMBER (A)
+
DATA STATION NUMBER (B) / 
TRUNK NUMBER (B)RELATED
COMMAND
No. MEANING DATA MEANING
00
99Memory Block 00...

Page 356

ND-45669 (E) CHAPTER 3
Pag e 3 17
Revision 2.0
CMA6
COMMAND CODE
TITLE:
ATTRIBUTE DATA FOR RS-232C PORT ON AP01
A6
MAT
4. DATA TABLE:
1. FUNCTION:
This command is used to assign the attribute data for the RS-232C port on the PN-AP01 card.
2. PRECAUTION:
None
3. ASSIGNMENT PROCEDURE:
: Initial Data
YY SETTING DATA
RECOMMENDED
SETTING
No. MEANING DATA MEANING
04 Data Transmission Speed of 
RS-232C Port0
1
2
3
4
5
6150 bps
300 bps
600 bps
1200 bps
2400 bps
4800 bps
9600 bps5
(example)
05 Parity Check 0
1...

Page 357

CHAPTER 3 ND-45669 (E)
Pag e 3 18
Revision 2.0
CMA6
COMMAND CODE
TITLE:
ATTRIBUTE DATA FOR RS-232C PORT ON AP01
A6
MAT
08 Stop Bit 0
1 2-Stop Bit
1-Stop Bit1
09 Type of Code 00
01
02
03
04
05
06
07
15 ASCII (7-bit) + even parity
ASCII (7-bit) + odd parity
ASCII (7-bit) + parity (0)
ASCII (7-bit) + parity (1)
JIS (7-bit) + even parity
JIS (7-bit) + odd parity
JIS (8-bit)
EBCDIC (8-bit)
Non character (Binary Data)06
10 DCD Signal check at Data Trans-
mission0
1 Ineffective
Effective0
(example)
11 RTS...

Page 358

ND-45669 (E) CHAPTER 3
Pag e 3 19
Revision 2.0
CMA6
COMMAND CODE
TITLE:
ATTRIBUTE DATA FOR RS-232C PORT ON AP01
A6
MAT
24 Kind of procedure 1
3
4Free Wheel 1
: Initial Data
YY SETTING DATA
RECOMMENDED
SETTING
No. MEANING DATA MEANING
Not used 

Page 359

CHAPTER 3 ND-45669 (E)
Pag e 3 20
Revision 2.0
CMA7
COMMAND CODE
TITLE:
CCIS CHANNEL DATA
A7
4. DATA TABLE:
1. FUNCTION:
This command assigns the various data to each Common Channel Handler (CCH) provided.
2. PRECAUTION:
None
3. ASSIGNMENT PROCEDURE:
: Initial Data
YY SETTING DATA
RELATED 
COMMAND
No. MEANING DATA MEANING
00 Assignment of the trunk used as the 
Common Signaling channel000
255Trunk number assigned by CM07 
YY = 01 / YY = 02
01 Assignment of the Originating Point 
Code (OPC)00001...

Page 360

ND-45669 (E) CHAPTER 3
Pag e 3 21
Revision 2.0
CMA7
COMMAND CODE
TITLE:
CCIS CHANNEL DATA
A7
05 Assignment of the Centralized Fault 
Reporting destination00001
16367Point Code of Centralized Fault Re-
porting office
06 Assignment of the Originating Of-
fice Number0
9999Originating Office Number
10 Assignment of the ACM signal wait-
ing timer after sending IAI signal 
when originating calls via CCIS.
Note:Assign the primary digit
number of the 5-digit sta-
tion number to be dis-
played.00
01
14
150 sec.
2...