Home > NEC > Communications System > NEC Neax2000 Ivs Circuit Card Manual

NEC Neax2000 Ivs Circuit Card Manual

    Download as PDF Print this page Share this page

    Have a look at the manual NEC Neax2000 Ivs Circuit Card Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							ND-45504 (E) CHAPTER 4
    Addendum-001 Page 68-1
    JULY, 1998 Revision 2.1
    PN-CC01 (ETHER)
    PN-CC01 (ETHER)
    1. Location of Lamps, Switches, and Connectors
    PN-CC01 (ETHER) Card
    RUN
    MB
    LINK
    XMT
    RCV
    RVP SW2
    SW1
    ERR
    10 BASE-T
    IP 
    						
    							CHAPTER 4 ND-45504 (E)
    Page 68-2 Addendum-001
    Revision 2.1 JULY, 1998
    PN-CC01 (ETHER)
    2. Lamp Indications
    Lamp Indications
    LAMP NAME COLOR FUNCTION
    RUN Green Flashes at 60 IPM while this card is operating normally.
    LINK Green Lights when link is established.
    XMT Green Lights when it is transmitting the data.
    RCV Green Lights when it is receiving the data.
    RVP Green Lights only when it is receiving the data with its own IP address.
    ERR Not used 
    						
    							ND-45504 (E) CHAPTER 4
    Addendum-001 Page 68-3
    JULY, 1998 Revision 2.1
    PN-CC01 (ETHER)
    3. Switch Settings
    Note 1:When the power is on, set the MB switch to ON (UP position) before plugging/unplugging the Circuit card.
    Note 2:Each equipment must have a unique MAC address to distinguish between systems. Therefore, when more
    than one PBX is installed in the same network, assign the lower 4 digits of the following MAC address by
    SW1 and SW2 to prevent duplicate addresses. 
    Switch Settings 
    SWITCH
    NAMESWITCH
    NUMBERSETTING
    POSITIONFUNCTION CHECK
    MB (Toggle SW)
    Note 1UP For make-busy
    For normal operation
    SW1 (Dip SW)
    Note 21 (D15) ON
    2 (D14) ON
    3 (D13) ON
    4 (D12) OFF
    5 (D11) ON
    OFF
    6 (D10) ON
    OFF
    7 (D9) ON
    OFF
    8 (D8) ON
    OFF
    SW2 (Dip SW)
    Note 21 (D7) ON
    OFF
    2 (D6) ON
    OFF
    3 (D5) ON
    OFF
    4 (D4) ON
    OFF
    5 (D3) ON
    OFF
    6 (D2) ON
    OFF
    7 (D1) ON
    OFF
    8 (D0) ON
    OFF
    00004CA4 XX XX (HEX)
    According to the switch setting of SW2 (D7-D0)
    According to the switch setting of SW1 (D15-D8)
    Fixed
    ON
    DOWN
    12345678 ONMAC ADDRESS SWITCH SETTING
    00004CA4 X X X X 
    (HEX)
    FixedSW1-1 (D15)
    SW1-2 (D14)
    SW1-3 (D13)
    SW1-4 (D12)ON/OFF
    ON/OFF
    ON/OFF
    ON/OFF
    SW1-5 (D11)
    SW1-6 (D10)
    SW1-7 (D9)
    SW1-8 (D8)ON/OFF
    ON/OFF
    ON/OFF
    ON/OFF
    SW2-1 (D7)
    SW2-2 (D6)
    SW2-3 (D5)
    SW2-4 (D4)ON/OFF
    ON/OFF
    ON/OFF
    ON/OFF
    SW2-5 (D3)
    SW2-6 (D2)
    SW2-7 (D1)
    SW2-8 (D0)ON/OFF
    ON/OFF
    ON/OFF
    ON/OFF
    ON: 0  OFF: 1
    12345678 ON 
    						
    							CHAPTER 4 ND-45504 (E)
    Page 68-4 Addendum-001
    Revision 2.1 JULY, 1998
    This page is for your notes. 
    						
    							ND-45504 (E) CHAPTER 4
    Page 69
    Revision 2.0
    PN-CK00 (PLO)
    PN-CK00 (PLO)
    1. Locations of Lamps, Switches, and Connectors
    PN-CK00 (PLO) Card
    2. Lamp Indications
    DRIFT: Means the status which the oscillation of clock signal from the PN-CK00 is not synchronized with
    the network.
    Lamp Indications
    LAMP NAME COLOR FUNCTION
    SYNC Green Lights while clock signals from this card are sent out and are not DRIFT status.
    PLO0 GreenLights while receiving clock signals from the network to the PLO0 input on this 
    card.
    PLO1 GreenLights while receiving clock signals from the network to the PLO1 input on this 
    card.
    ALM Red Lights while clock signal from this card are not sent out.
    DRFT Red Lights while clock signals are DRIFT status.
    ALMDRFT
    MB
    SW0
    PLO0 SYNC
    PLO1 
    						
    							CHAPTER 4 ND-45504 (E)
    Page 70 Addendum-001
    Revision 2.1 JULY, 1998
    PN-CK00 (PLO)
    (3) Switch Settings
    The figure in the SWITCH NAME column and the position in   in the SETTING POSITION
    column indicate the standard setting of the switch. When the switch is not set as shown by the figure and
    , the setting of the switch varies with the system concerned.
    Switch Settings
    SWITCH NAMESWITCH
    NUMBERSETTING
    POSITIONFUNCTION CHECK
    MB (Toggle SW)
    NoteUP For make-busy
    For normal operation
    SW0 (Piano Key SW)
    1, 2Selection of PLO 0 (Phase Locked Oscillator)
    3, 4Selection of PLO 1 (Phase Locked Oscillator)
    5 ~ 7 Not used
    8ON PLO frequency hold circuit OFF
    PLO frequency hold circuit ON
    ON
    DOWN
    ON
     
    
    
    
    
    
    
    
    
    
    
    OFF
    8
    7
    6
    5
    4
    3
    2
    1
    SWITCH NUMBER
    FUNCTION
    12
    ON ON2 MHz clock 
    [For PN-30DTC/PN-30DTC-A/
    PN-2BRTC]
    OFF ON1.5 MHz clock
    [For PN-24DTA/PN-24DTA-A]
    ON OFF192 kHz clock
    [For PN-BRTA]
    OFF OFF Not used
    SWITCH NUMBER
    FUNCTION
    34
    ON ON2 MHz clock
    [For PN-30DTC/PN-30DTC-A/
    PN-2BRTC]
    OFF ON1.5 MHz clock 
    [For PN-24DTA/PN-24DTA-A]
    ON OFF192 kHz clock
    [For PN-BRTA]
    OFF OFF Not used
    OFF
    OFF 
    						
    							ND-45504 (E) CHAPTER 4
    Addendum-001 Page 71
    JULY, 1998 Revision 2.1
    PN-CK00 (PLO)
    Note 1:
    When the power is on, flip the MB switch ON (UP position) before plugging/unplugging the circuit card.
    Note 2:When using this card, set the SW2 switch on the PN-CP00/PN-CP00-B/PN-CP03 (MP) as follows.
    SW2-2: OFF
    SW2-3: ON
    Note 3:When using this card for providing a master office clock signal, set the SW0 switch on the PN-CK00 and
    the SW switch on the PN-24DTA/PN-24DTA-A or the PN-30DTC/PN-30DTC-A mounted in PIM0 as fol-
    lows.
    • PN-CK00 card • PN-24DTA/PN-24DTA-A card • PN-30DTC/PN-30DTC-A card
    SW0-1: OFF SW-1: OFF SW-1: OFF
    SW0-2: OFF SW-2: OFF SW-2: OFF
    SW0-3: OFF
    SW0-4: OFF
    SW0-8: ON
    Note 4:When using this card as a sub-master, set the SW0 switch on the PN-CK00 and the SW switch on the
    PN-24DTA/PN-24DTA-A or the PN-30DTC/PN-30DTC-A as follows:
    For 1.5MHz interface:
    • PN-CK00 card • PN-24DTA/PN-24DTA-A card
    SW0-1: OFF SW-1: ON
    SW0-2: ON SW-2: OFF
    SW0-3: OFF
    SW0-4: ON*
    SW0-8: ON
    * Set to ON, when more than one DTI card is mounted in PIM0, or set to OFF when only one DTI
    card is mounted in PIM0.
    For 2MHz interface:
    • PN-CK00 card • PN-30DTC/PN-30DTC-A card
    SW0-1: ON SW-1: ON
    SW0-2: ON SW-2: OFF
    SW0-3: ON
    SW0-4: ON*
    SW0-8: ON
    * Set to ON, when more than one DTI card is mounted in PIM0, or set to OFF when only one DTI
    card is mounted in PIM0. 
    						
    							CHAPTER 4 ND-45504 (E)
    Pag e 72
    Revision 2.0
    PN-24DTA (DTI)
    PN-24DTA (DTI)
    1. Locations of Lamps, Switches, and Connectors
    PN-24DTA (DTI) Card
    2. Lamp Indications
    Lamp Indications
    LAMP NAME COLOR FUNCTION
    RUN Green Flashes at 120 IPM while this card is operating normally.
    CRC Red Lights when detecting Cyclic Redundancy Checking (CRC) errors.
    PCM Red Lights when detecting PCM signal loss.
    FRM Red Lights when detecting a Frame Alignment signal loss.
    RMT Red Lights when receiving a Frame Alignment signal loss alarm from a distant office.
    AIS RedLights when a pattern of consecutive “1” bits  is received. The distant office transmits this 
    signal for a loop-back test.
    BL RedB channel status
    ON  : More than 10 channels are busy
    OFF  : All channels are idle
    Flash (60 IPM):Only one channel is busy
    Flash (120 IPM):2 through 10 channels are busy
    SENS
    RUN
    MB
    SW
    CRCPCM
    FRM
    RMT
    AIS
    BL
    JPS
    JPR1
    JPR0 
    						
    							ND-45504 (E) CHAPTER 4
    Page 73
    Revision 2.0
    PN-24DTA (DTI)
    (3) Switch Settings
    Switch Settings 
    SWITCH
    NAMESWITCH
    NUMBERSETTING
    POSITIONFUNCTION CHECK
    SENS
    (Rotary SW)
    Note 14 - F Set the switch to match the AP Number (04 - 15) to be set by CM05.
    0 - 3 Not used
    MB (Toggle SW)
    Note 2UPFor make-busy
    For normal operation
    SW
    (Piano Key SW)
    1ONClock signal from a master office is sent to the PLO 0 in-
    put on the MP card.
    OFFClock signal from a master office is not sent to the PLO 
    0 input on the MP card. 
    2ONClock signal from a master office is sent to the PLO 1 in-
    put on the MP card.
    OFFClock signal from a master office is not sent to the PLO 
    1 input on the MP card. 
    3ON Remote loop-back
    For normal operation
    4ON Local loop-back (AIS send)
    For normal operation
    5Set the equalizer according to the cable length 
    between the PBX and the MDF.
    OFF
    6
    OFF
    7
    OFF
    8 Always set to OFF
    AP NO.
    SW NO.10 04 05 06 07 08 09 11 12 13 14 15
    456 789ABCDEF
    ON
    DOWN
    ON
    OFF
    4
    3
    2
    1
    5 6 7
    8
    OFF
    OFF
    ON
    OFF
    80 - 120 m (262.5 - 394 ft.) SW-5 SW-6 SW-7 CABLE LENGTH
    ON ON0 - 40 m ( 0 - 131.2 ft.)
    40 - 80 m (131.2 - 262.5 ft.)
    120 - 160 m (394 - 525 ft.)
    160 - 200 m (525 - 656 ft.)
    Signal is not sent ON ON ON
    ON ON OFF
    OFF ON OFF
    ON OFF ON
    OFF OFF OFF
    ON
    ON
    OFF 
    						
    							CHAPTER 4 ND-45504 (E)
    Pag e 74
    Revision 2.0
    PN-24DTA (DTI)
    The figure in the SWITCH NAME column and the position in   in the SETTING POSITION col-
    umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
     , the setting of the switch varies with the system concerned.
    Note 1:Set the groove on the switch knob to the intended switch position.
    Note 2:When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit
    card.
    Note 3:Set SW-1 and SW-2 as follows: 
    Note 4:When the PBX is the master office, set the SW-1 and SW-2 on all the DTI cards mounted in PIM0 to
    “OFF”.
    Switch Settings (Continued)
    SWITCH
    NAMESWITCH
    NUMBERSETTING
    POSITIONFUNCTION CHECK
    JPS (Jumper pin) Neutral grounding on the transmitting line is not provid-
    ed.
    LeftNeutral grounding on the transmitting line is provided.
    JPR0 (Jumper pin) Neutral grounding on the receiving line is not provided.
    DownNeutral grounding on the receiving line is provided.
    JPR1 (Jumper pin)
    RightLine impedance : 110 ohms
    Line impedance : 100 ohms
    DTI0 DTI1 DTI2 DTI3 DTI4
    REMARKS
    SW
    -1SW
    -2SW
    -1SW
    -2SW
    -1SW
    -2SW
    -1SW
    -2SW
    -1SW
    -2
    When one DTI is 
    provided ON OFFThe MP card receives the clock 
    signal from DTI0 at its PLO0 in-
    put.
    When more than one 
    DTI is provided
    ON OFF OFF ON OFF OFF OFF OFF OFF OFFThe MP card receives the clock 
    signal from DTI0 at its PLO0 in-
    put under normal conditions.
    Should a clock failure occur with 
    DTI0, the MP card switches to the 
    PLO1 input, which gets clock 
    from DTI1.
    Right
    Up
    Left
    CONDITIONSSW NO. OF DTI 
    						
    All NEC manuals Comments (0)