NEC Neax2000 Ivs Circuit Card Manual
Have a look at the manual NEC Neax2000 Ivs Circuit Card Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
![](/img/blank.gif)
ND-45504 (E) CHAPTER 4 Addendum-001 Page 68-1 JULY, 1998 Revision 2.1 PN-CC01 (ETHER) PN-CC01 (ETHER) 1. Location of Lamps, Switches, and Connectors PN-CC01 (ETHER) Card RUN MB LINK XMT RCV RVP SW2 SW1 ERR 10 BASE-T IP
![](/img/blank.gif)
CHAPTER 4 ND-45504 (E) Page 68-2 Addendum-001 Revision 2.1 JULY, 1998 PN-CC01 (ETHER) 2. Lamp Indications Lamp Indications LAMP NAME COLOR FUNCTION RUN Green Flashes at 60 IPM while this card is operating normally. LINK Green Lights when link is established. XMT Green Lights when it is transmitting the data. RCV Green Lights when it is receiving the data. RVP Green Lights only when it is receiving the data with its own IP address. ERR Not used
![](/img/blank.gif)
ND-45504 (E) CHAPTER 4 Addendum-001 Page 68-3 JULY, 1998 Revision 2.1 PN-CC01 (ETHER) 3. Switch Settings Note 1:When the power is on, set the MB switch to ON (UP position) before plugging/unplugging the Circuit card. Note 2:Each equipment must have a unique MAC address to distinguish between systems. Therefore, when more than one PBX is installed in the same network, assign the lower 4 digits of the following MAC address by SW1 and SW2 to prevent duplicate addresses. Switch Settings SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK MB (Toggle SW) Note 1UP For make-busy For normal operation SW1 (Dip SW) Note 21 (D15) ON 2 (D14) ON 3 (D13) ON 4 (D12) OFF 5 (D11) ON OFF 6 (D10) ON OFF 7 (D9) ON OFF 8 (D8) ON OFF SW2 (Dip SW) Note 21 (D7) ON OFF 2 (D6) ON OFF 3 (D5) ON OFF 4 (D4) ON OFF 5 (D3) ON OFF 6 (D2) ON OFF 7 (D1) ON OFF 8 (D0) ON OFF 00004CA4 XX XX (HEX) According to the switch setting of SW2 (D7-D0) According to the switch setting of SW1 (D15-D8) Fixed ON DOWN 12345678 ONMAC ADDRESS SWITCH SETTING 00004CA4 X X X X (HEX) FixedSW1-1 (D15) SW1-2 (D14) SW1-3 (D13) SW1-4 (D12)ON/OFF ON/OFF ON/OFF ON/OFF SW1-5 (D11) SW1-6 (D10) SW1-7 (D9) SW1-8 (D8)ON/OFF ON/OFF ON/OFF ON/OFF SW2-1 (D7) SW2-2 (D6) SW2-3 (D5) SW2-4 (D4)ON/OFF ON/OFF ON/OFF ON/OFF SW2-5 (D3) SW2-6 (D2) SW2-7 (D1) SW2-8 (D0)ON/OFF ON/OFF ON/OFF ON/OFF ON: 0 OFF: 1 12345678 ON
![](/img/blank.gif)
CHAPTER 4 ND-45504 (E) Page 68-4 Addendum-001 Revision 2.1 JULY, 1998 This page is for your notes.
![](/img/blank.gif)
ND-45504 (E) CHAPTER 4 Page 69 Revision 2.0 PN-CK00 (PLO) PN-CK00 (PLO) 1. Locations of Lamps, Switches, and Connectors PN-CK00 (PLO) Card 2. Lamp Indications DRIFT: Means the status which the oscillation of clock signal from the PN-CK00 is not synchronized with the network. Lamp Indications LAMP NAME COLOR FUNCTION SYNC Green Lights while clock signals from this card are sent out and are not DRIFT status. PLO0 GreenLights while receiving clock signals from the network to the PLO0 input on this card. PLO1 GreenLights while receiving clock signals from the network to the PLO1 input on this card. ALM Red Lights while clock signal from this card are not sent out. DRFT Red Lights while clock signals are DRIFT status. ALMDRFT MB SW0 PLO0 SYNC PLO1
![](/img/blank.gif)
CHAPTER 4 ND-45504 (E) Page 70 Addendum-001 Revision 2.1 JULY, 1998 PN-CK00 (PLO) (3) Switch Settings The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. Switch Settings SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK MB (Toggle SW) NoteUP For make-busy For normal operation SW0 (Piano Key SW) 1, 2Selection of PLO 0 (Phase Locked Oscillator) 3, 4Selection of PLO 1 (Phase Locked Oscillator) 5 ~ 7 Not used 8ON PLO frequency hold circuit OFF PLO frequency hold circuit ON ON DOWN ON OFF 8 7 6 5 4 3 2 1 SWITCH NUMBER FUNCTION 12 ON ON2 MHz clock [For PN-30DTC/PN-30DTC-A/ PN-2BRTC] OFF ON1.5 MHz clock [For PN-24DTA/PN-24DTA-A] ON OFF192 kHz clock [For PN-BRTA] OFF OFF Not used SWITCH NUMBER FUNCTION 34 ON ON2 MHz clock [For PN-30DTC/PN-30DTC-A/ PN-2BRTC] OFF ON1.5 MHz clock [For PN-24DTA/PN-24DTA-A] ON OFF192 kHz clock [For PN-BRTA] OFF OFF Not used OFF OFF
![](/img/blank.gif)
ND-45504 (E) CHAPTER 4 Addendum-001 Page 71 JULY, 1998 Revision 2.1 PN-CK00 (PLO) Note 1: When the power is on, flip the MB switch ON (UP position) before plugging/unplugging the circuit card. Note 2:When using this card, set the SW2 switch on the PN-CP00/PN-CP00-B/PN-CP03 (MP) as follows. SW2-2: OFF SW2-3: ON Note 3:When using this card for providing a master office clock signal, set the SW0 switch on the PN-CK00 and the SW switch on the PN-24DTA/PN-24DTA-A or the PN-30DTC/PN-30DTC-A mounted in PIM0 as fol- lows. • PN-CK00 card • PN-24DTA/PN-24DTA-A card • PN-30DTC/PN-30DTC-A card SW0-1: OFF SW-1: OFF SW-1: OFF SW0-2: OFF SW-2: OFF SW-2: OFF SW0-3: OFF SW0-4: OFF SW0-8: ON Note 4:When using this card as a sub-master, set the SW0 switch on the PN-CK00 and the SW switch on the PN-24DTA/PN-24DTA-A or the PN-30DTC/PN-30DTC-A as follows: For 1.5MHz interface: • PN-CK00 card • PN-24DTA/PN-24DTA-A card SW0-1: OFF SW-1: ON SW0-2: ON SW-2: OFF SW0-3: OFF SW0-4: ON* SW0-8: ON * Set to ON, when more than one DTI card is mounted in PIM0, or set to OFF when only one DTI card is mounted in PIM0. For 2MHz interface: • PN-CK00 card • PN-30DTC/PN-30DTC-A card SW0-1: ON SW-1: ON SW0-2: ON SW-2: OFF SW0-3: ON SW0-4: ON* SW0-8: ON * Set to ON, when more than one DTI card is mounted in PIM0, or set to OFF when only one DTI card is mounted in PIM0.
![](/img/blank.gif)
CHAPTER 4 ND-45504 (E) Pag e 72 Revision 2.0 PN-24DTA (DTI) PN-24DTA (DTI) 1. Locations of Lamps, Switches, and Connectors PN-24DTA (DTI) Card 2. Lamp Indications Lamp Indications LAMP NAME COLOR FUNCTION RUN Green Flashes at 120 IPM while this card is operating normally. CRC Red Lights when detecting Cyclic Redundancy Checking (CRC) errors. PCM Red Lights when detecting PCM signal loss. FRM Red Lights when detecting a Frame Alignment signal loss. RMT Red Lights when receiving a Frame Alignment signal loss alarm from a distant office. AIS RedLights when a pattern of consecutive “1” bits is received. The distant office transmits this signal for a loop-back test. BL RedB channel status ON : More than 10 channels are busy OFF : All channels are idle Flash (60 IPM):Only one channel is busy Flash (120 IPM):2 through 10 channels are busy SENS RUN MB SW CRCPCM FRM RMT AIS BL JPS JPR1 JPR0
![](/img/blank.gif)
ND-45504 (E) CHAPTER 4 Page 73 Revision 2.0 PN-24DTA (DTI) (3) Switch Settings Switch Settings SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SENS (Rotary SW) Note 14 - F Set the switch to match the AP Number (04 - 15) to be set by CM05. 0 - 3 Not used MB (Toggle SW) Note 2UPFor make-busy For normal operation SW (Piano Key SW) 1ONClock signal from a master office is sent to the PLO 0 in- put on the MP card. OFFClock signal from a master office is not sent to the PLO 0 input on the MP card. 2ONClock signal from a master office is sent to the PLO 1 in- put on the MP card. OFFClock signal from a master office is not sent to the PLO 1 input on the MP card. 3ON Remote loop-back For normal operation 4ON Local loop-back (AIS send) For normal operation 5Set the equalizer according to the cable length between the PBX and the MDF. OFF 6 OFF 7 OFF 8 Always set to OFF AP NO. SW NO.10 04 05 06 07 08 09 11 12 13 14 15 456 789ABCDEF ON DOWN ON OFF 4 3 2 1 5 6 7 8 OFF OFF ON OFF 80 - 120 m (262.5 - 394 ft.) SW-5 SW-6 SW-7 CABLE LENGTH ON ON0 - 40 m ( 0 - 131.2 ft.) 40 - 80 m (131.2 - 262.5 ft.) 120 - 160 m (394 - 525 ft.) 160 - 200 m (525 - 656 ft.) Signal is not sent ON ON ON ON ON OFF OFF ON OFF ON OFF ON OFF OFF OFF ON ON OFF
![](/img/blank.gif)
CHAPTER 4 ND-45504 (E) Pag e 74 Revision 2.0 PN-24DTA (DTI) The figure in the SWITCH NAME column and the position in in the SETTING POSITION col- umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. Note 1:Set the groove on the switch knob to the intended switch position. Note 2:When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit card. Note 3:Set SW-1 and SW-2 as follows: Note 4:When the PBX is the master office, set the SW-1 and SW-2 on all the DTI cards mounted in PIM0 to “OFF”. Switch Settings (Continued) SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK JPS (Jumper pin) Neutral grounding on the transmitting line is not provid- ed. LeftNeutral grounding on the transmitting line is provided. JPR0 (Jumper pin) Neutral grounding on the receiving line is not provided. DownNeutral grounding on the receiving line is provided. JPR1 (Jumper pin) RightLine impedance : 110 ohms Line impedance : 100 ohms DTI0 DTI1 DTI2 DTI3 DTI4 REMARKS SW -1SW -2SW -1SW -2SW -1SW -2SW -1SW -2SW -1SW -2 When one DTI is provided ON OFFThe MP card receives the clock signal from DTI0 at its PLO0 in- put. When more than one DTI is provided ON OFF OFF ON OFF OFF OFF OFF OFF OFFThe MP card receives the clock signal from DTI0 at its PLO0 in- put under normal conditions. Should a clock failure occur with DTI0, the MP card switches to the PLO1 input, which gets clock from DTI1. Right Up Left CONDITIONSSW NO. OF DTI