    							ND-45504 (E) CHAPTER 4
    Page 63
    Revision 2.0
    PN-BRTA (BRI)
    (2) Lamp Indications
    Lamp Indications on the PN-BRTA (BRI) Card
    LAMP NAME COLOR FUNCTION
    RUN Green Flashes at 120 IPM while this card is operating normally.
    B1 GreenB1 channel status
    ON: Busy
    OFF: Idle
    Flash (60 IPM):Make Busy
    B2 GreenB2 channel status
    ON: Busy
    OFF: Idle
    Flash (60 IPM):Make Busy
    DGreenD channel status
    ON: Busy
    OFF: Idle
    ALM RedTransmission line fault status
    ON: Line fault
    OFF: Normal operation 
    						
    							CHAPTER 4 ND-45504 (E)
    Pag e 64
    Revision 2.0
    PN-BRTA (BRI)
    (3) Switch Settings
    The figure in the SWITCH NAME column and the position in   in the SETTING POSITION col-
    umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
     , the setting of the switch varies with the system concerned.
    Note 1:Set the groove on the switch knob to the desired switch position.
    Note 2:When the power is on, set the MB switch to ON (UP position) before plugging/unplugging the circuit
    card.
    Switch Settings on the PN-BRTA (BRI) Card 
    SWITCH
    NAMESWITCH
    NUMBERSETTING
    POSITIONFUNCTION CHECK
    SENS
    (Rotary SW)
    Note 14 - F Set the switch to match the AP Number (04 - 15) as set by CM05.
    0 - 3 Not used
    MB (Toggle SW)
    Note 2UPFor make-busy
    For normal operation
    SW0 (Dip SW)
    1For normal operation (BRI mode)
    OFF Not used
    2
    Note 3ONClock signal from a master office is sent to the PLO of 
    MP card according to the switch setting of SW0-3.
    OFFClock signal from a master office is not sent to the PLO 
    of MP card.
    3
    Note 3ON Clock signal is sent to PLO 0 of MP card.
    OFF Clock signal is sent to PLO 1 of MP card.
    4For normal operation
    OFF Not used
    SW1 (Dip SW)
    1For terminating the transmitting side of channels B1 and 
    B2 with 100 ohms.
    OFFTo remove the terminating resistor on the transmitting 
    side of channels B1 and B2.
    2For terminating the receiving side of channels B1 and B2 
    with 100 ohms.
    OFFTo remove the terminating resistor on the receiving side 
    of channels B1 and B2.
    0AP NO.
    SW NO.10 04 05 06 07 08 09 11 12 13 14 15
    456 789ABCDEF
    ON
    DOWN
    ON43 2 1
    ON
    ON
    ON2 1
    ON
    ON 
    						
    							ND-45504 (E) CHAPTER 4
    Page 65
    Revision 2.0
    PN-BRTA (BRI)
    Note 3:
    Set SW0-2 and SW0-3 as follows.
    BRI 0 BRI 1 BRI 2 .... BRI 11
    REMARKS
    SW 
    0-2SW 
    0-3SW 
    0-2SW 
    0-3SW 
    0-2SW 
    0-3....SW 
    0-2SW 
    0-3
    When one BRI is 
    provided.ON ONThe MP card will receive the clock signal 
    from BRI 0 at its PLO 0 input.
    When more than 
    one BRI is pro-
    vided.
    ON ON ON OFF OFF ON .... OFF ONThe MP card will receive the clock signal 
    from BRI 0 at its PLO 0 input under nor-
    mal conditions.
    Should a clock failure occur on BRI 0, the 
    MP card will automatically switch to the 
    PLO 1 input, and so derive the clock from 
    BRI 1.No. of BRI
    SW
    CONDITIONS 
    						
    							PN-2BRTC (BRI)
    CHAPTER 4 ND-45504 (E)
    Page 65-1 Addendum-001
    Revision 2.1 JULY, 1998
    PN-2BRTC (BRI)
    1. Locations of Lamps, Switches, and connectors
    PN-2BRTC (BRI) Card
    RU N
    SENS
    MB
    SW0
    D1
    ALM1
    B20
    B10
    SW11SW10
    D0
    ALM0
    B21
    B11 
    						
    							PN-2BRTC (BRI)
    ND-45504 (E) CHAPTER 4
    Addendum-001 Page 65-2
    JULY, 1998 Revision 2.1
    2. Lamp Indications
    Lamp Indications
    LAMP NAME COLOR FUNCTION
    RUN Green Flashes at 120 IPM while this card is operating normally.
    B21 Red No.1 Circuit B2 channel status
    ON: Busy
    OFF: Idle
    Flash (60 IPM):  Make Busy
    B11 Red B1 channel status
    ON: Busy
    OFF: Idle
    Flash (60 IPM):  Make Busy
    D1 Green D channel status
    ON: Busy
    OFF: Idle
    ALM1 Red Transmission line fault status
    ON: Line fault
    OFF: Normal operation
    B20 Red No.0 Circuit B2 channel status
    ON: Busy
    OFF: Idle
    Flash (60 IPM):  Make Busy
    B10 Red B1 channel status
    ON: Busy
    OFF: Idle
    Flash (60 IPM):  Make Busy
    D0 Green D channel status
    ON: Busy
    OFF: Idle
    ALM0 Red Transmission line fault status
    ON: Line fault
    OFF: Normal operation 
    						
    							PN-2BRTC (BRI)
    CHAPTER 4 ND-45504 (E)
    Page 65-3 Addendum-001
    Revision 2.1 JULY, 1998
    3. Switch Settings
    Switch Settings
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIONFUNCTION CHECK
    SENS
    (Rotary SW)
    Note 14 ~ F Set the switch to match the AP Number (04-15) as set by
    CM05.
    0 
    ~ 3 Not used
    MB (Toggle SW)
    Note 2UP For make-busy
    For normal operation
    SW0, SW10
    (Dip SW)
    1For terminating the transmitting side
    of channels B1 and B2 with 100 ohms.
    OFFTo remove the terminating resistor on
    the transmitting side of channels B1
    and B2.
    2For terminating the receiving side of
    channels B1 and B2 with 100 ohms.
    OFFTo remove the terminating resistor on
    the receiving side of channels B1 and
    B2.
    0
    AP No.
    04 05 06 07 08 09 10 11 12 13 14 15
    SW No.
    456789ABCDEF
    ON
    DOWN
    1ON2
    ON
    ON 
    						
    							PN-2BRTC (BRI)
    ND-45504 (E) CHAPTER 4
    Addendum-001 Page 65-4
    JULY, 1998 Revision 2.1
    The figure in the SWITCH NAME column and the position in   in the SETTING POSITION
    column indicate the standard setting of the switch. When the switch is not set as shown by the figure and
    , the setting of the switch varies with the system concerned.
    Note 1:Set the groove on the switch knob to the desired switch position.
    Note 2:When the power is on, set the MB switch to ON (UP position) before plugging/unplugging the circuit
    card.
    Note 3:
    The system can supply clock signals from two clock supply routes.
    In normal condition, the system synchronizes to the clock signals supplied on the PLO 0 of MP card via
    the Back Wiring Board, and if the clock signals are failed, the clock supply route takes over to PLO1
    automatically. Set SW11-2 and SW11-3 as follows. SW11 (Dip SW)
    1For normal operation (BRI mode)
    OFF Not used
    2
    Note 3ONOutput clock signals according to the
    switch setting of SW11-3.
    OFF Do not output clock signals.
    3
    Note 3ON Output clock signals to PLO 0 of MP.
    OFF Output clock signals to PLO 1 of MP.
    4For normal operation
    OFF Not used
    BRI  0 BRI  1 BRI  2 ---- BRI  11
    REMARKS
    SW
    11-2SW
    11-3SW
    11-2SW
    11-3SW
    11-2SW
    11-3----SW
    11-2SW
    11-3
    When one BRI is 
    provided.ON ONThe clock signals are supplied to the
    PLO through No. 0 circuit the BRI. If
    the clock supply route of No. 0 circuit
    is failed, the clock supply route of No.
    1 circuit takes over automatically.
    When more than 
    one BRI is pro-
    vided.ON ON ON OFF OFF ON
    ----OFF ONThe system can supply the clock
    signals from BRI 0 or BRI 1. The
    system is synchronized to the BRI 0
    clock signals normally, and if both
    No. 0 circuit clock supply route and
    No. 1 circuit clock supply route is
    failed, the BRI 1 takes over. Switch Settings (Continued)
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIONFUNCTION CHECK
    1234 ON
    ON
    ON
    No. of
    BRI
    SW
    CONDITIONS 
    						
    							CHAPTER 4 ND-45504 (E)
    Pag e 66
    Revision 2.0
    PN-CC00 (ETHER)
    PN-CC00 (ETHER)
    1. Locations of Lamps, Switches, and Connectors
    PN-CC00 (ETHER) Card
    ETHER
    RUN
    IP
    SW31
    SW
    ERR
    S1
    S2
    S3RUN
    SW
    ERR
    S1
    S2
    S3 PN-CC00 PZ-M397
    SW51 
    						
    							ND-45504 (E) CHAPTER 4
    Addendum-001 Page 67
    JULY, 1998 Revision 2.1
    PN-CC00 (ETHER)
    2. Lamp Indications
    Lamp Indications
    LAMP NAME COLOR FUNCTION
    RUN Green Steadily lights while this card is operating normally.
    ERR Red Flashes at 120 IPM when system error occurs.
    S1 Green Lights when it is transmitting or receiving the data.
    S2 Green Lights when it can transmit or receive the data.
    S3 Green Lights when the power sets ON. 
    						
    							CHAPTER 4 ND-45504 (E)
    Pag e 68
    Revision 2.0
    PN-CC00 (ETHER)
    (3) Switch Settings
    Note:Each equipment must have a unique MAC address to distinguish between systems. Therefore, when more
    than one PBX is installed in the same network, assign the lower 3 digits of the following MAC address by
    SW31 and SW51 to prevent duplicate addresses. 
    Switch Settings 
    SWITCH
    NAMESWITCH
    NUMBERSETTING
    POSITIONFUNCTION CHECK
    SW
    (Rotary SW)0Always set to 0
    1-FNot used
    SW51 (Dip SW)
    Note1 (D15) ON
    2 (D14) ON
    3 (D13) ON
    4 (D12) OFF
    5 (D11) ON
    OFF
    6 (D10) ON
    OFF
    7 (D9) ON
    OFF
    8 (D8) ON
    OFF
    SW31 (Dip SW)
    Note1 (D7) ON
    OFF
    2 (D6) ON
    OFF
    3 (D5) ON
    OFF
    4 (D4) ON
    OFF
    5 (D3) ON
    OFF
    6 (D2) ON
    OFF
    7 (D1) ON
    OFF
    8 (D0) ON
    OFF
    000032251   XXX (HEX)
    According to the switch setting of SW51 (D11-D8) and SW31 (D7-D0).
    Fixed
    12345678 ONMAC ADDRESS SWITCH SETTING
    00003225   1  X X X 
    (HEX)
        FixedSW51-1 (D15)
    SW51-2 (D14)
    SW51-3 (D13)
    SW51-4 (D12)ON
    ON
    ON
    OFF
    SW51-5 (D11)
    SW51-6 (D10)
    SW51-7 (D9)
    SW51-8 (D8)ON/OFF
    ON/OFF
    ON/OFF
    ON/OFF
    SW31-1 (D7)
    SW31-2 (D6)
    SW31-3 (D5)
    SW31-4 (D4)ON/OFF
    ON/OFF
    ON/OFF
    ON/OFF
    SW31-5 (D3)
    SW31-6 (D2)
    SW31-7 (D1)
    SW31-8 (D0)ON/OFF
    ON/OFF
    ON/OFF
    ON/OFF
    ON:0  OFF:1