NEC Neax2000 Ivs Circuit Card Manual
Have a look at the manual NEC Neax2000 Ivs Circuit Card Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
ND-45504 (E) CHAPTER 4 Page 63 Revision 2.0 PN-BRTA (BRI) (2) Lamp Indications Lamp Indications on the PN-BRTA (BRI) Card LAMP NAME COLOR FUNCTION RUN Green Flashes at 120 IPM while this card is operating normally. B1 GreenB1 channel status ON: Busy OFF: Idle Flash (60 IPM):Make Busy B2 GreenB2 channel status ON: Busy OFF: Idle Flash (60 IPM):Make Busy DGreenD channel status ON: Busy OFF: Idle ALM RedTransmission line fault status ON: Line fault OFF: Normal operation
CHAPTER 4 ND-45504 (E) Pag e 64 Revision 2.0 PN-BRTA (BRI) (3) Switch Settings The figure in the SWITCH NAME column and the position in in the SETTING POSITION col- umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. Note 1:Set the groove on the switch knob to the desired switch position. Note 2:When the power is on, set the MB switch to ON (UP position) before plugging/unplugging the circuit card. Switch Settings on the PN-BRTA (BRI) Card SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SENS (Rotary SW) Note 14 - F Set the switch to match the AP Number (04 - 15) as set by CM05. 0 - 3 Not used MB (Toggle SW) Note 2UPFor make-busy For normal operation SW0 (Dip SW) 1For normal operation (BRI mode) OFF Not used 2 Note 3ONClock signal from a master office is sent to the PLO of MP card according to the switch setting of SW0-3. OFFClock signal from a master office is not sent to the PLO of MP card. 3 Note 3ON Clock signal is sent to PLO 0 of MP card. OFF Clock signal is sent to PLO 1 of MP card. 4For normal operation OFF Not used SW1 (Dip SW) 1For terminating the transmitting side of channels B1 and B2 with 100 ohms. OFFTo remove the terminating resistor on the transmitting side of channels B1 and B2. 2For terminating the receiving side of channels B1 and B2 with 100 ohms. OFFTo remove the terminating resistor on the receiving side of channels B1 and B2. 0AP NO. SW NO.10 04 05 06 07 08 09 11 12 13 14 15 456 789ABCDEF ON DOWN ON43 2 1 ON ON ON2 1 ON ON
ND-45504 (E) CHAPTER 4 Page 65 Revision 2.0 PN-BRTA (BRI) Note 3: Set SW0-2 and SW0-3 as follows. BRI 0 BRI 1 BRI 2 .... BRI 11 REMARKS SW 0-2SW 0-3SW 0-2SW 0-3SW 0-2SW 0-3....SW 0-2SW 0-3 When one BRI is provided.ON ONThe MP card will receive the clock signal from BRI 0 at its PLO 0 input. When more than one BRI is pro- vided. ON ON ON OFF OFF ON .... OFF ONThe MP card will receive the clock signal from BRI 0 at its PLO 0 input under nor- mal conditions. Should a clock failure occur on BRI 0, the MP card will automatically switch to the PLO 1 input, and so derive the clock from BRI 1.No. of BRI SW CONDITIONS
PN-2BRTC (BRI) CHAPTER 4 ND-45504 (E) Page 65-1 Addendum-001 Revision 2.1 JULY, 1998 PN-2BRTC (BRI) 1. Locations of Lamps, Switches, and connectors PN-2BRTC (BRI) Card RU N SENS MB SW0 D1 ALM1 B20 B10 SW11SW10 D0 ALM0 B21 B11
PN-2BRTC (BRI) ND-45504 (E) CHAPTER 4 Addendum-001 Page 65-2 JULY, 1998 Revision 2.1 2. Lamp Indications Lamp Indications LAMP NAME COLOR FUNCTION RUN Green Flashes at 120 IPM while this card is operating normally. B21 Red No.1 Circuit B2 channel status ON: Busy OFF: Idle Flash (60 IPM): Make Busy B11 Red B1 channel status ON: Busy OFF: Idle Flash (60 IPM): Make Busy D1 Green D channel status ON: Busy OFF: Idle ALM1 Red Transmission line fault status ON: Line fault OFF: Normal operation B20 Red No.0 Circuit B2 channel status ON: Busy OFF: Idle Flash (60 IPM): Make Busy B10 Red B1 channel status ON: Busy OFF: Idle Flash (60 IPM): Make Busy D0 Green D channel status ON: Busy OFF: Idle ALM0 Red Transmission line fault status ON: Line fault OFF: Normal operation
PN-2BRTC (BRI) CHAPTER 4 ND-45504 (E) Page 65-3 Addendum-001 Revision 2.1 JULY, 1998 3. Switch Settings Switch Settings SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SENS (Rotary SW) Note 14 ~ F Set the switch to match the AP Number (04-15) as set by CM05. 0 ~ 3 Not used MB (Toggle SW) Note 2UP For make-busy For normal operation SW0, SW10 (Dip SW) 1For terminating the transmitting side of channels B1 and B2 with 100 ohms. OFFTo remove the terminating resistor on the transmitting side of channels B1 and B2. 2For terminating the receiving side of channels B1 and B2 with 100 ohms. OFFTo remove the terminating resistor on the receiving side of channels B1 and B2. 0 AP No. 04 05 06 07 08 09 10 11 12 13 14 15 SW No. 456789ABCDEF ON DOWN 1ON2 ON ON
PN-2BRTC (BRI) ND-45504 (E) CHAPTER 4 Addendum-001 Page 65-4 JULY, 1998 Revision 2.1 The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. Note 1:Set the groove on the switch knob to the desired switch position. Note 2:When the power is on, set the MB switch to ON (UP position) before plugging/unplugging the circuit card. Note 3: The system can supply clock signals from two clock supply routes. In normal condition, the system synchronizes to the clock signals supplied on the PLO 0 of MP card via the Back Wiring Board, and if the clock signals are failed, the clock supply route takes over to PLO1 automatically. Set SW11-2 and SW11-3 as follows. SW11 (Dip SW) 1For normal operation (BRI mode) OFF Not used 2 Note 3ONOutput clock signals according to the switch setting of SW11-3. OFF Do not output clock signals. 3 Note 3ON Output clock signals to PLO 0 of MP. OFF Output clock signals to PLO 1 of MP. 4For normal operation OFF Not used BRI 0 BRI 1 BRI 2 ---- BRI 11 REMARKS SW 11-2SW 11-3SW 11-2SW 11-3SW 11-2SW 11-3----SW 11-2SW 11-3 When one BRI is provided.ON ONThe clock signals are supplied to the PLO through No. 0 circuit the BRI. If the clock supply route of No. 0 circuit is failed, the clock supply route of No. 1 circuit takes over automatically. When more than one BRI is pro- vided.ON ON ON OFF OFF ON ----OFF ONThe system can supply the clock signals from BRI 0 or BRI 1. The system is synchronized to the BRI 0 clock signals normally, and if both No. 0 circuit clock supply route and No. 1 circuit clock supply route is failed, the BRI 1 takes over. Switch Settings (Continued) SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK 1234 ON ON ON No. of BRI SW CONDITIONS
CHAPTER 4 ND-45504 (E) Pag e 66 Revision 2.0 PN-CC00 (ETHER) PN-CC00 (ETHER) 1. Locations of Lamps, Switches, and Connectors PN-CC00 (ETHER) Card ETHER RUN IP SW31 SW ERR S1 S2 S3RUN SW ERR S1 S2 S3 PN-CC00 PZ-M397 SW51
ND-45504 (E) CHAPTER 4 Addendum-001 Page 67 JULY, 1998 Revision 2.1 PN-CC00 (ETHER) 2. Lamp Indications Lamp Indications LAMP NAME COLOR FUNCTION RUN Green Steadily lights while this card is operating normally. ERR Red Flashes at 120 IPM when system error occurs. S1 Green Lights when it is transmitting or receiving the data. S2 Green Lights when it can transmit or receive the data. S3 Green Lights when the power sets ON.
CHAPTER 4 ND-45504 (E) Pag e 68 Revision 2.0 PN-CC00 (ETHER) (3) Switch Settings Note:Each equipment must have a unique MAC address to distinguish between systems. Therefore, when more than one PBX is installed in the same network, assign the lower 3 digits of the following MAC address by SW31 and SW51 to prevent duplicate addresses. Switch Settings SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SW (Rotary SW)0Always set to 0 1-FNot used SW51 (Dip SW) Note1 (D15) ON 2 (D14) ON 3 (D13) ON 4 (D12) OFF 5 (D11) ON OFF 6 (D10) ON OFF 7 (D9) ON OFF 8 (D8) ON OFF SW31 (Dip SW) Note1 (D7) ON OFF 2 (D6) ON OFF 3 (D5) ON OFF 4 (D4) ON OFF 5 (D3) ON OFF 6 (D2) ON OFF 7 (D1) ON OFF 8 (D0) ON OFF 000032251 XXX (HEX) According to the switch setting of SW51 (D11-D8) and SW31 (D7-D0). Fixed 12345678 ONMAC ADDRESS SWITCH SETTING 00003225 1 X X X (HEX) FixedSW51-1 (D15) SW51-2 (D14) SW51-3 (D13) SW51-4 (D12)ON ON ON OFF SW51-5 (D11) SW51-6 (D10) SW51-7 (D9) SW51-8 (D8)ON/OFF ON/OFF ON/OFF ON/OFF SW31-1 (D7) SW31-2 (D6) SW31-3 (D5) SW31-4 (D4)ON/OFF ON/OFF ON/OFF ON/OFF SW31-5 (D3) SW31-6 (D2) SW31-7 (D1) SW31-8 (D0)ON/OFF ON/OFF ON/OFF ON/OFF ON:0 OFF:1 12345678 ON