    							ND-45504 (E) CHAPTER 3
    Page 13
    Revision 2.0
    2.4 PN-BS00-A/PN-BS00-B (BS00), PN-BS01-A/PN-BS01-B (BS01)
    1. In a one-PIM system, neither the PN-BS00-A/PN-BS00-B nor the PN-BS01-A/PN-BS01-B is needed.
    2. When the system is equipped with more than one PIM, mount a PN-BS00-A/PN-BS00-B in the BUS slot
    of PIM0 or PIM(H)0.
    3. When the system is equipped with more than one PIM, mount one PN-BS01-A/PN-BS01-B in the BUS
    slot of PIM1 through PIM7, as required.
    Figure 3-4   BS00/BS01 Card Mounting Slots
    2.5 PN-PW00 (EXTPWR)
    Mount the PW00 card into the LT01-AP8 slot. A maximum of three PW00 cards can be mounted in one frame
    (4PIMs). 
    Note:The PW00 card occupies the adjoining left side (smaller number) slot because of its two-stories structure.
    2.6 PZ-PW86 (PWR)
    Mount one PZ-PW86 in the PWR slot of PIM0/PIM(H)0 through PIM7, as required.
    PIM3PIM7B
    S
    0
    1B
    S
    0
    1
    PIM2PIM6
    B
    S
    0
    1B
    S
    0
    1
    PIM1PIM5
    B
    S
    0
    1B
    S
    0
    1
    PIM0PIM4
    B
    S
    0
    1B
    S
    0
    0 or
    PIM(H)0 
    						
    							CHAPTER 3 ND-45504 (E)
    Page 14 Addendum-001
    Revision 2.1 JULY, 1998
    3. INSTALLATION CONDITIONS FOR APPLICATION CIRCUIT CARDS
    1. When the system is equipped with only one PIM:
    • An application circuit card can be mounted in the AP0 through AP6, and AP8 slots.
    • An application circuit card can not be mounted in the AP6 slot if any of the following is true.
    – A PN-2DLCC is used.
    – A PN-AP01 is used.
    – OAI, ACD, No. 7 CCIS or ISDN is used.
    – The PN-CP02s are used.
    2. When the system is equipped with more than one PIM:
    • An application circuit card can be mounted in the AP0 through AP5 slots of PIM0/PIM(D)0.
    • An application circuit card can be mounted in the AP0 through AP6 slots of PIM2, 4 and 6.
    • An application circuit card can be mounted in the AP0 through AP7 slots of PIM1, 3, 5 and 7.
    • If the system is equipped with CP02s, the AP5 and AP6 slot of PIM(H)0 cannot be used for an appli-
    cation circuit card.
    Note 1:
    The application circuit card (PN-24DTA/PN-24DTA-A/PN-30DTC/PN-30DTC-A) cannot be mounted
    in either the AP7 or the AP8 slot since neither of these slots have a connection to the MDF through the
    Back Wiring Board.
    Note 2:
    The application circuit card (PN-24DTA/PN-24DTA-A/PN-30DTC/PN-30DTC-A [DT10, DT11] which
    receives a clock signal must be mounted in the AP0 through AP5 slots of PIM0/PIM(H)0.
    Note 3:
    The application circuit card (PN-CK00) must be mounted in the AP0 through AP6 slots of PIM0/
    PIM(H)0.
    Note 4:
    The application circuit card (PN-CC00/PN-CC01) can be mounted in any one of the LT slots or the AP
    slots.
    PN-CC00 card needs two LT/AP slots per one card.
    Note 5:
    The application circuit card (PN-CC00/PN-CC01) should be mounted in a LT/AP slot that adjoins an
    AP slot for the PN-AP01 card because the cable (48-TW0.3 CONN CA) is connected between the PN-
    CC00/PN-CC01 card and the PN-AP01 card. 
    						
    							ND-45504 (E) CHAPTER 3
    Page 15
    Revision 2.0
    Figure 3-5   Application Circuit Card Mounting Slots
    •Line/trunk circuit cards can also be mounted in AP0 - AP5 slots.
    BUS/AP8FP/AP6 MP/FP/AP7
    BUILT-IN BATTERY PIM0-7
    AP5
    AP4
    AP3
    AP2
    AP1
    AP0
    PWR*
    LT SLOTS (00-09)
    •Line/trunk circuit cards can also be mounted in AP0 - AP5 slots.
    BUS/AP8MP1 MP0
    BUILT-IN BATTERY PIMH (0)
    AP5
    AP4
    AP3
    AP2
    AP1
    AP0
    PWR*
    LT SLOTS (00-09) 
    						
    							CHAPTER 3 ND-45504 (E)
    Pag e 16
    Revision 2.0
    4. INSTALLATION CONDITIONS FOR LINE/TRUNK CIRCUIT CARDS
    Mount the line/trunk circuit cards in the LT00 through LT15 slots of PIM0/PIM(H)0 through PIM7.
    Figure 3-6   Line/Trunk Circuit Card Mounting Slots
    •Application circuit cards can also be mounted in the LT10 through LT15 slots.
    BUS/AP8AP6 MP/FP/AP7
    BUILT-IN BATTERY PIM0-7
    LT15
    LT14
    LT13
    LT12
    LT11
    LT10
    LT09
    LT08
    LT07
    LT00 LT01
    LT02 LT03 LT04 LT05 LT06
    PWR*
    •Application circuit cards can also be mounted in the LT10 through LT15 slots.
    BUS/AP8MP1 MP0
    BUILT-IN BATTERY PIM(H)0
    LT15
    LT14
    LT13
    LT12
    LT11
    LT10
    LT09
    LT08
    LT07
    LT00 LT01 LT02 LT03
    LT04 LT05 LT06
    PWR* 
    						
    							ND-45504 (E) CHAPTER 4
    Page 17
    Revision 2.0
    CHAPTER 4 LAMP INDICATIONS AND SWITCH SETTINGS
    This chapter explains various circuit cards used in the PBX with respect to the following items. Explanations
    are given in the alphabetical order of the circuit card names within each circuit card category (Control, Appli-
    cation, and Line/Trunk).
    1. Locations of Lamps, Switches, and Connectors
    The locations of lamps, switches, and connectors of each circuit card are shown by a face layout.
    2. Lamp Indications
    The name, color, and functions of each indicator lamp equipped on each circuit card are shown and de-
    scribed in a table.
    3. Switch Settings
    The name, settings, and functions of each switch equipped on each circuit card are shown and described in
    a table.
    Each switch setting table has a “CHECK” column. Make necessary entries in the CHECK column during and/
    or after system installation and maintenance, and use each table as a reference for subsequent system mainte-
    nance and operations. 
    						
    							CHAPTER 4 ND-45504 (E)
    Pag e 18
    Revision 2.0
    1. PRECAUTION IN HANDLING
    When handling a circuit card, the installer must wear a grounded wrist strap to protect the circuit card from static
    electricity.
    Figure 4-1   Static Electricity Precautions (1 of 2)
    CARD FRONT
    PBX
    WRIST STRAP •  WHEN PLUGGING/UNPLUGGING A CIRCUIT CARD
    •  WHEN HOLDING A CIRCUIT CARD
    FRAME GROUND SCREW
    CONNECT THE GROUND WIRE TO THE 
    FRAME EARTH OF THE EQUIPMENT.
    NEVER TOUCH THE COMPONENTS OR 
    SOLDERED SURFACE WITH BARE HANDS. 
    						
    							ND-45504 (E) CHAPTER 4
    Page 19
    Revision 2.0
    Figure 4-1  Static Electricity Precautions (2 of 2)
    WEAR A WRIST STRAP AND PERFORM
    THE WORK STANDING ON A GROUNDED
    CONDUCTIVE WORK SURFACE.
    WHEN CARRYING A CIRCUIT
    CARD AROUND, KEEP THE
    CARD IN THE CONDUCTIVE
    POLYETHYLENE BAG. CONDUCTIVE
    POLYETHYLENE
    BAG CIRCUIT
        CARDCIRCUIT
        CARD •  WHEN SETTING SWITCHES ON A CIRCUIT CARD
    •  WHEN CARRYING A CIRCUIT CARD 
    						
    							CHAPTER 4 ND-45504 (E)
    Pag e 20
    Revision 2.0
    Figure 4-2   Circuit Card Handling Precautions
    CARD FRONT
    NEVER TOUCH THE COMPONENTS 
    OR SOLDERED SURFACE WITH 
    BASE HANDS.
    PBX
    The installer must hold the edge of circuit card, when plugging or unplugging the circuit card.  If you touch
    another area, you may be exposed to hazardous voltages.
    CAUTION 
    						
    							ND-45504 (E) CHAPTER 4
    Addendum-002 Page 21
    OCTOBER, 1998 Revision 2.2
    2. LAMP INDICATIONS AND SWITCH SETTINGS OF CONTROL CIRCUIT CARDS
    Table 4-1 below shows the control circuit cards to be explained in this section.
    * MB = Make Busy
    Table 4-1  Table of Control Circuit Cards
    NAME
    (FUNCTIONAL 
    NAME)EXISTENCE OF 
    LAMPS
    X: PROVIDED
    —: NOT PROVIDEDEXISTENCE OF 
    SWITCHES
    X: PROVIDED
    —: NOT PROVIDEDEXTRACTION/INSERTION 
    WITH POWER ON
    X: ALLOWED
    D: ALLOWED AFTER MB*
    —: NOT ALLOWEDREFERENCE 
    PA G E
    PN-BS00-A/
    PN-BS00-B (BS00)—X
    D22
    PN-BS01-A (BS01) — X
    D24
    PN-BS01-B (BS01) — X
    D26
    PN-CP00 (MP) X X —28
    PN-CP00-B
    /PN-CP00-C (MP)XX —31
    PN-CP03
    /PN-CP03-C (MP)XX —34
    PN-CP01 (FP) X X
    D37
    PN-CP02
    /PN-CP02-C (MP)XX
    D39
    PN-PW00 
    (EXTPWR)XX
    D42
    PZ-PW86 (PWR) X X —44
    PZ-PW86-A (PWR) X X —46
    PZ-PW86(C) (PWR) X X —48
    PZ-PW86(D) 
    (PWR)XX —50 
    						
    							CHAPTER 4 ND-45504 (E)
    Pag e 22
    Revision 2.0
    PN-BS00-A/PN-BS00-B (BS00)
    PN-BS00-A/PN-BS00-B (BS00)
    1. Locations of Lamps, Switches, and Connectors
    PN-BS00-A/PN-BS00-B (BS00) Card
    2. Lamp Indications
    This card has no indicator lamps.
    MB