    							ND-45504 (E) CHAPTER 4
    Page 43
    Revision 2.0
    PN-PW00 (EXTPWR)
    (3) Switch Setting
    The figure in the SWITCH NAME column and the position in   in the SETTING POSITION col-
    umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
    , the setting of the switch varies with the system concerned.
    Note:When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit card.
    Switch Settings 
    SWITCH
    NAMESWITCH
    NUMBERSETTING
    POSITIONFUNCTION
    CHECK
    MB (Toggle SW)
    NoteUPFor make-busy (–48 V power off)
    For normal operation (–48 V power on)
    ON
    DOWN 
    						
    							CHAPTER 4 ND-45504 (E)
    Pag e 44
    Revision 2.0
    PZ-PW86 (PWR)
    PZ-PW86 (PWR)
    1. Locations of Lamps, Switches, and Connectors
    PZ-PW86 (PWR) Card
    2. Lamp Indications
    Lamp Indications
    LAMP NAME COLOR FUNCTION
    MJ Red Lights upon occurrence of a major trouble
    MN Yellow Lights upon occurrence of a minor trouble
    ON Green Remains lit while the operating power is being supplied
    FRONT VIEW SIDE VIEWMJ
    MN
    ONMN MJ
    ON
    GND
    –27V FG
    GND
    –27V FG
    OFFON –
    240 100/120 1
    2 ON
    SW102 
    						
    							ND-45504 (E) CHAPTER 4
    Page 45
    Revision 2.0
    PZ-PW86 (PWR)
    (3) Switch Settings
    The figure in the SWITCH NAME column and the position in   in the SETTING POSITION col-
    umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
    , the setting of the switch varies with the system concerned.
    Switch Settings
    SWITCH NAMESWITCH 
    NUMBERSETTING
    POSITIONFUNCTION CHECK
    1Set to ON.
    2ONStandard setting (for equalize charging)
    OFFNot used
    SW
    ONFor turning AC source power on
    OFFFor turning AC source power off
    100/120
    240AC INPUT: 90 V - 138 V
    DOWNAC INPUT: 180 V - 276 V
    CAUTION
    • When the operating power is being supplied to this circuit card, do not plug/unplug this circuit card into/from
    its mounting slot.
    • Set the appropriate voltage by using the AC voltage select switch (slide switch) before powering on.
    1
    2 ON
    ON
    I (ON)
    O (OFF)
    UP 
    						
    							CHAPTER 4 ND-45504 (E)
    Pag e 46
    Revision 2.0
    PZ-PW86-A (PWR)
    PZ-PW86-A (PWR)
    1. Locations of Lamps, Switches, and Connectors
    PZ-PW86-A (PWR) Card
    2. Lamp Indications
    Lamp Indications
    LAMP NAME COLOR FUNCTION
    MJ Red Lights upon occurrence of a major trouble
    MN Yellow Lights upon occurrence of a minor trouble
    ON Green Remains lit while the operating power is being supplied
    FRONT VIEW SIDE VIEWMJ
    MN
    ONMN MJ
    ON
    GND
    –27V FG
    GND
    –27V FG
    OFFON –
    240 100/120 1
    2 ON
    SW102SW102 
    						
    							ND-45504 (E) CHAPTER 4
    Page 47
    Revision 2.0
    PZ-PW86-A (PWR)
    (3) Switch Settings
    The figure in the SWITCH NAME column and the position in   in the SETTING POSITION col-
    umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
    , the setting of the switch varies with the system concerned.
    Switch Settings
    SWITCH NAMESWITCH 
    NUMBERSETTING
    POSITIONFUNCTION CHECK
    SW102
    PRESS 
    MOMENTARILYTo start each PIM on battery power, when AC 
    power is not provided (Switch “SW” must be 
    ON).
    1 Set to ON.
    2ON For float charging
    OFFStandard setting for equalize charging (Set to 
    equalize for Gel cell or no battery.)
    SW
    ON For turning AC source power on
    OFF For turning AC source power off
    100/120
    240AC INPUT: 90 V - 138 V
    DOWN AC INPUT: 180 V - 276 V
    CAUTION
    • When the operating power is being supplied to this circuit card, do not plug/unplug this circuit card into/from
    its mounting slot.
    • Set the appropriate voltage by using the AC voltage select switch (slide switch) before powering on.
    1
    2 ON
    ON
    I (ON)
    O (OFF)
    UP 
    						
    							CHAPTER 4 ND-45504 (E)
    Pag e 48
    Revision 2.0
    PZ-PW86 (C) (PWR)
    PZ-PW86 (C) (PWR)
    1. Locations of Lamps, Switches, and Connectors
    PZ-PW86(C) (PWR) Card
    2. Lamp Indications
    Lamp Indications
    LAMP NAME COLOR FUNCTION
    MJ Red Lights upon occurrence of a major trouble
    MN Orange Lights upon occurrence of a minor trouble
    ON Green Remains lit while the operating power is being supplied
    FRONT VIEW BATT2 MN MJ
    ONBATTERY
    SIDE VIEW GND
    –27V FG
    OFFON
    240VAC 100/120VAC 2ON
    2
    1 ON SW102
    START
    SIG
    1
    SW1
    BATT1
    AC INPUTMODE
    SW301 
    						
    							ND-45504 (E) CHAPTER 4
    Page 49
    Revision 2.0
    PZ-PW86 (C) (PWR)
    (3) Switch Settings
    The figure in the SWITCH NAME column and the position in    in the SETTING POSITION col-
    umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
    , the setting of the switch varies with the system concerned. Switch Settings
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIONFUNCTION CHECK
    MODE 1 Always set to OFF
    2Float charging, for sealed batteries (Normal 
    Setting).
    OPTION: Periodic Equalize charging of 
    external vented batteries.
    OFFFlaot charging, for vented batteries only.
    SW1 For turning AC power and the battery on
    OFFFor turning AC power and the battery off
    AC INPUT: 90 V - 138 V
    DOWNAC INPUT: 180 V - 264 V
    SW102
    PRESS
    MOMENTARILYTo start each PIM on battery power, when 
    AC power is not provided (switch “SW” 
    must be ON)
    SW301
    1ON CR Voltage: 75 Vrms
    CR Voltage: 90 Vrms
    2Frequency: 20 Hz
    OFFFrequency: 25 Hz
    ON
    1
    2
    OFF
    ON
    OFF (O) ON (I)
    ON
    240 VAC 100/120 VAC
    UP
    25Hz
    1 2
    OFF
    90V 20Hz
    ON
    75V
    OFF
    ON 
    						
    							CHAPTER 4 ND-45504 (E)
    Pag e 50
    Revision 2.0
    PZ-PW86 (D) (PWR)
    PZ-PW86 (D) (PWR)
    1. Locations of Lamps, Switches, and Connectors
    PZ-PW86(D) (PWR) Card
    2. Lamp Indications
    Lamp Indications
    LAMP NAME COLOR FUNCTION
    MJ Red Lights upon occurrence of a major trouble
    MN Orange Lights upon occurrence of a minor trouble
    ON Green Remains lit while the operating power is being supplied
    FRONT VIEWBATT2 MN MJ
    ON
    BATTERY
    SIDE VIEW GND
    –27V FG
    OFFON 240VAC 100/120VAC2ON
    2
    1 ON SW102
    START
    SIG
    1
    SW1 BATT1
    AC INPUTMODE
    SW301
    (CN103) SIG
    (CN103) 
    						
    							ND-45504 (E) CHAPTER 4
    Page 51
    Revision 2.0
    PZ-PW86 (D) (PWR)
    (3) Switch Settings
    The figure in the SWITCH NAME column and the position in    in the SETTING POSITION col-
    umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
    , the setting of the switch varies with the system concerned.
    Switch Settings
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIONFUNCTION CHECK
    MODE 1 Always set to OFF
    2Float charging, for sealed batteries (Normal 
    Setting).
    OPTION: Periodic Equalize charging of 
    external vented batteries.
    OFFFlaot charging, for vented batteries only.
    SW1 For turning AC power and the battery on
    OFFFor turning AC power and the battery off
    AC INPUT: 90 V - 138 V
    DOWNAC INPUT: 180 V - 264 V
    SW102
    PRESS
    MOMENTARILYTo start each PIM on battery power, when 
    AC power is not provided (switch “SW” 
    must be ON)
    SW301
    1ON CR Voltage: 75 Vrms
    CR Voltage: 90 Vrms
    2Frequency: 20 Hz
    OFFFrequency: 25 Hz
    ON
    1
    2
    OFF
    ON
    OFF (O) ON (I)
    ON
    240 VAC 100/120 VAC
    UP
    25Hz
    1 2
    OFF
    90V 20Hz
    ON
    75V
    OFF
    ON 
    						
    							CHAPTER 4 ND-45504 (E)
    Page 52 Addendum-001
    Revision 2.1 JULY, 1998
    3. LAMP INDICATIONS AND SWITCH SETTINGS OF APPLICATION CIRCUIT CARDS
    Table 4-2 below shows the application circuit cards to be explained in this section.
    * MB=Make Busy
    Table 4-2  Table of Application Circuit Cards
    NAME
    (FUNCTIONAL 
    NAME)EXISTENCE OF 
    LAMPS
    X: PROVIDED
    —: NOT PROVIDEDEXISTENCE OF 
    SWITCHES
    X: PROVIDED
    —: NOT PROVIDEDEXTRACTION/INSER-
    TION WITH POWER ON
    X: ALLOWED
    D: ALLOWED AFTER MB*
    —: NOT ALLOWED
    REFERENCE 
    PAG E
    PN-AP00-A (AP00)
    XXD53
    PN-AP01 (AP01)
    XXD59
    PN-BRTA (BRI)
    XXD62
    PN-2BRTC (BRI)
    XXD65-1
    PN-CC00 (ETHER)
    XX X66
    PN-CC01 (ETHER)
    XXD68-1
    PN-CK00 (PLO)
    XXD69
    PN-24DTA (DTI)
    XXD72
    PN-24DTA-A (DTI)
    XXD75
    PN-30DTC/30DTC-A 
    (DTI)XXD78-1
    PN-ME00 (EXTMEM)
    XXD79
    PN-4RSTB (MFR)
    XXD84
    PN-4RSTC (CIR)
    XXD86
    PN-SC00 (CCH)
    XXD88
    PN-SC01 (DCH)
    XXD91
    PN-SC02 (ICH)
    XXD94
    PN-SC03 (ICH)
    XXD96
    PN-SC03 (CSH)
    XXD98 
    						