ND-45504 (E) CHAPTER 4 Page 53 Revision 2.0 PN-AP00-A (AP00) PN-AP00-A (AP00) 1. Locations of Lamp, Switches, and Connectors PN-AP00-A (AP00) Card MB SW0 SENSE RUN MB SW1 WE RS3 L3 L2 L1 L0 RS2 RS1 RS0 J16
CHAPTER 4 ND-45504 (E) Pag e 54 Revision 2.0 PN-AP00-A (AP00) (2) Lamp Indications Lamp Indications LAMP NAME COLOR FUNCTION RUN Green Flashes at 120 IPM while this card is operating normally. WE Red Not used. L0 - L3 GreenSecond data setting value for the first data 250 of CM D001 0 1 (port 0) - 3 (port 2) L3Indication of the transmitting status of port 0Indication of the status of CTS signal on port 0 - 2 L2Indication of the transmitting status of port 1Indication of the status of DCD signal on port 0 - 2 L1Indication of the transmitting status of port 2Indication of the status of TXD signal on port 0 - 2 L0Indication of the transmitting status of port 3Indication of the status of RXD signal on port 0 - 2
ND-45504 (E) CHAPTER 4 Page 55 Revision 2.0 PN-AP00-A (AP00) (3) Switch Settings Switch Settings SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SENSE (Rotary SW) Note 14 - FSet the switch to match the AP Number (04 - 15) to be set by CM05. 0 - 3 Not used MB (Toggle SW) Note 2UP For make-busy For normal operation SW1 (Piano Key SW) 1For normal operation OFF Not used 2For normal operation OFF For AP data clearing by CMD100/CMD101 3For normal operation OFF For AP data clearing by CMD100/CMD101 4 Always set to OFF J16 (Jumper pin) Fro nt Memory backup ON LEFTMemory backup OFF AP NO. SW NO.10 04 05 06 07 08 09 11 12 13 14 15 456 789ABCDEF ON DOWN ON OFF 4 3 2 1 ON ON ON OFF RIGHT
CHAPTER 4 ND-45504 (E) Pag e 56 Revision 2.0 PN-AP00-A (AP00) SW0 (Dip SW) 1 Note 3ONEnables the receive clock from the DCE (Mo- dem) side when the No. 0 Port is synchronous. (Clock is received at the RXC terminal.) OFF• Uses the internal clock as the receive clock when the No. 0 Port is synchronous • When the No. 0 Port is asynchronous 2ONEnables transmit clock from the DCE (Mo- dem) side when the No. 0 Port is synchronous. (Clock is received at the TXC (2) terminal.) OFF• Uses the internal clock as the send clock when the No. 0 Port is synchronous • When the No. 0 Port is asynchronous 3ONFor transmitting the send clock from the DTE (this card) when the No. 0 Port is synchro- nous. (Clock is transmitted from the TXC (1) terminal.) OFF• For not transmitting the send clock from the DTE (this card) side when the No. 0 Port is synchronous • When the No. 0 Port is asynchronous 4ON When the No. 0 Port is asynchronous OFF When the No. 0 Port is synchronous Switch Settings (Continued) SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK 12345678 ON
ND-45504 (E) CHAPTER 4 Page 57 Revision 2.0 PN-AP00-A (AP00) The figure in the SWITCH NAME column and the position in in the SETTING POSITION col- umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. Switch Settings (Continued) SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SW0 5 Note 4ON• Uses the internal clock as the receive clock when the No. 0 Port is synchro- nous. • When the No. 0 Port is asynchronous. OFFEnables receive clock from the DCE (Mo- dem) side when the No. 0 Port is synchro- nous. (Clock is received at the RXC terminal) 6 Note 5ONSet No. 0 port forcibly in a state which DSR signal is always provided. Force DSR sig- nal high for port 0. No SMDR buffering. OFFReceive DSR signal from the DCE on No. 0 port. Detect DSR signal from DCE for port 0. Allows SMDR records to buffer. 7 Note 5ONSet No. 1 port forcibly in a state which DSR signal is always provided. Force DSR sig- nal high for port 1. No SMDR buffering. OFFReceive DSR signal from the DCE on No. 1 port. Detect DSR signal from DCE for port 1. Allows SMDR records to buffer. 8 Note 5ONSet No. 2 port forcibly in a state which DSR signal is always provided. Force DSR signal high for port 2. No SMDR buffering. OFFReceive DSR signal from the DCE on No. 2 port. Detect DSR signal from DCE for port 2. Allows SMDR records to buffer.
CHAPTER 4 ND-45504 (E) Pag e 58 Revision 2.0 PN-AP00-A (AP00) Note 1: Set the groove on the switch knob to the desired switch position. Note 2:When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit card. Note 3:The SW 1 is used to select the AP operating mode as shown below. On line : Normal operating mode. The AP should be always in the “On line”, other than when you delete the AP data. Off line : The mode for AP data clearing by the command CMD100/CMD101. Note 4:The use of the external clock (from the distant end) or the internal clock is determined by the following table: Note 5:When the DCE connected to the port does not provide a function to send the DSR signals, set the switch to ON. In this case, the AP00 card can not recognize the actual state of the DCE, so that the call records or system messages will not be stored in the memory buffer on the AP00 card even if the cable is discon- nected from the DCE. When the switch is set to OFF, the call records or system messages will be stored when the cable is dis- connected, and will be sent when the cable is re-connected. SWITCH ON LINE OFF LINE SW 1-4 OFF OFF SW 1-3 ON OFF SW 1-2 ON OFF SW 1-1 ON ON CLOCKSW0 15 External ON OFF Internal OFF ON
ND-45504 (E) CHAPTER 4 Page 59 Revision 2.0 PN-AP01 (AP01) PN-AP01 (AP01) 1. Locations of Lamps, Switches, and Connectors PN-AP01 (AP01) Card 2. Lamp Indications Lamp Indications LAMP NAME COLOR FUNCTION RUN Green Flashes at 120 IPM while this card is operating normally. L0-L3L3 GreenIndication of the status of CTS signal on the RS-232C port. L2 Indication of the status of DCD signal on the RS-232C port. L1 Indication of the status of TXD signal on the RS-232C port L0 Indication of the status of RXD signal on the RS-232C port. MB SW0 SENSE RUN MB SW1 RS0 L3 L2 L1 L0 IP
CHAPTER 4 ND-45504 (E) Pag e 60 Revision 2.0 PN-AP01 (AP01) (3) Switch Settings Switch Settings SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SENSE (Rotary SW) Note 14 - F Set the switch to match the AP Number (04 - 15) to be set by CM05. 0 - 3 Not used MB(Toggle SW) Note 2UP For make-busy For normal operation SW1 (Piano Key SW)1For normal operation OFF Not used 2For normal operation OFF Not used 3For normal operation OFF Not used 4For normal operation OFFNot used AP NO. SW NO.10 04 05 06 07 08 09 11 12 13 14 15 456 789ABCDEF ON DOWN ON OFF 4 3 2 1 ON ON ON ON
ND-45504 (E) CHAPTER 4 Page 61 Revision 2.0 PN-AP01 (AP01) The figure in the SWITCH NAME column and the position in in the SETTING POSITION col- umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. Note 1:Set the groove on the switch knob to the desired switch position. Note 2:When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit card. SW0 (Dip SW) 1 Always set to OFF 2 Always set to OFF 3 Always set to OFF 4Always set to OFF Switch Settings (Continued) SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK 1234 ON OFF OFF OFF OFF
CHAPTER 4 ND-45504 (E) Pag e 62 Revision 2.0 PN-BRTA (BRI) PN-BRTA (BRI) 1. Locations of Lamps, Switches, and Connectors PN-BRTA (BRI) Card SENS RUN MB B1 B2 D ALM SW0 SW1