    							ND-45504 (E) CHAPTER 4
    Page 89
    Revision 2.0
    PN-SC00 (CCH)
    (3) Switch Settings
    Switch Settings 
    SWITCH
    NAMESWITCH
    NUMBERSETTING
    POSITIONFUNCTION CHECK
    SENS
    (Rotary SW)
    Note 14 - F Set the switch to match the AP Number (04 - 15) to be set by CM05.
    0 - 3 Not used
    MB(Toggle SW)
    Note 2UP For make-busy
    For normal operation
    SW0
    (Piano Key SW)1ON Loop-back test
    For normal operation
    2ON Analog interface
    OFF Digital interface
    3ONRS-232C RTS signal (to MODEM) ON 
    Note 3
    OFF RS-232C RTS signal (to MODEM) OFF
    4Always set to ON
    AP NO.
    SW NO.10 04 05 06 07 08 09 11 12 13 14 15
    456 789ABCDEF
    ON
    DOWN
    ON
    OFF
    4
    3
    2
    1
    OFF
    ON 
    						
    							CHAPTER 4 ND-45504 (E)
    Pag e 90
    Revision 2.0
    PN-SC00 (CCH)
    The figure in the SWITCH NAME column and the position in   in the SETTING POSITION col-
    umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
     , the setting of the switch varies with the system concerned.
    Note 1:Set the groove on the switch knob to the desired switch position.
    Note 2:When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit
    card.
    Note 3:This setting is available when SW0-2 is set to ON (Analog Interface).
    Note 4:The followimg two kinds of rate adaptation method are available when using 48 Kbps data transmis-
    sion. The rate adaptation method must be set to match the rate adaptation of the master office.
    SW1(Dip SW)1ON• Common channel signalling data transmission speed
    (For Digital Interface)
    • Common channel signalling data transmission speed
    (For Analog Interface)
    Set switches (SW1-1 - SW1-5) to OFF. OFF
    2ON
    OFF
    3ON
    OFF
    4ON
    OFF
    5ON
    OFF
    6ONA-Law
    OFFm-law
    7Always set to OFF
    8 Always set to OFFSwitch Settings  (Continued)
    SWITCH
    NAMESWITCH
    NUMBERSETTING
    POSITIONFUNCTION CHECK
    ON2 134 6857
    TRANSMISSION
    SPEEDSW
    1-1SW
    1-2SW 
    1-3SW 
    1-4SW 
    1-5
    48Kbps ¨ ON ON OFF OFF ON
    48Kbps ¦ ONONONOFFON
    56Kbps ON ON OFF ON ON
    64Kbps ONONONONON
    OFF
    OFF
    11
    48 Kbps
    Data 1
    SW1-3: OFF
    11
    48 Kbps
    2SW1-3: ON
    Data 
    						
    							ND-45504 (E) CHAPTER 4
    Page 91
    Revision 2.0
    PN-SC01 (DCH)
    PN-SC01 (DCH)
    1. Locations of Lamps, Switches and Connectors
    PN-SC01 (DCH) Card
    2. Lamp Indications
    Lamp Indications
    LAMP NAME COLOR FUNCTION
    RUN Green Flashes at 120 IPM while this card is operating normally.
    LC Green Lights when communications are normally ongoing with the D channel data links connected.
    LPB Green Not used.
    SENS
    RUN
    MB
    SW0
    LC
    LPB SW1 
    						
    							CHAPTER 4 ND-45504 (E)
    Pag e 92
    Revision 2.0
    PN-SC01 (DCH)
    (3) Switch Settings
    Switch Settings 
    SWITCH
    NAMESWITCH
    NUMBERSETTING
    POSITIONFUNCTION CHECK
    SENS
    (Rotary SW)
    Note 14 - F Set the switch to match the AP Number (04 - 15) to be set by CM05.
    0 - 3 Not used
    MB(Toggle SW)
    Note 2UP For make-busy
    For normal operation
    SW0
    (Piano Key SW)
    1OFF AT&T Interface
    ON Northern Telecom Interface
    2OFF No deletion
    ON Delete the first three digits of all 011 International Calls.
    3 Always set to OFF
    4 Always set to ON
    SW1 (Dip SW)
    1 Always set to OFF
    2 Always set to OFF
    3 Always set to OFF
    4 Always set to OFF
    5 Always set to OFF
    6 Always set to OFF
    7 Always set to OFF
    8 Always set to OFF
    AP NO.
    SW NO.10 04 05 06 07 08 09 11 12 13 14 15
    456 789ABCDEF
    ON
    DOWN
    ON
    OFF
    4
    3
    2
    1
    OFF
    ON
    ON2 134 6857
    OFF
    OFF
    OFF
    OFF
    OFF
    OFF
    OFF
    OFF 
    						
    							ND-45504 (E) CHAPTER 4
    Page 93
    Revision 2.0
    PN-SC01 (DCH)
    The figure in the SWITCH NAME column and the position in   in the SETTING POSITION col-
    umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
     , the setting of the switch varies with the system concerned.
    Note 1:Set the groove on the switch knob onto the intended switch position.
    Note 2:When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit
    card. 
    						
    							CHAPTER 4 ND-45504 (E)
    Pag e 94
    Revision 2.0
    PN-SC02 (ICH)
    PN-SC02 (ICH)
    1. Locations of Lamps, Switches, and Connectors 
    PN-SC02 (ICH) Card
    2. Lamp Indications
    Lamp Indications
    LAMP NAME COLOR FUNCTION
    RUN Green Flashes at 120 IPM while this card is operating normally.
    DOPE0 GreenON:  No. 0 circuit D channel link is connected.
    OFF: No. 0 circuit D channel link is not connected.
    DOPE1 GreenON:  No. 1 circuit D channel link is connected.
    OFF: No. 1 circuit D channel link is not connected.
    RUN
    MB
    SW0
    SENS
    DOPE1
    DOPE0 
    						
    							ND-45504 (E) CHAPTER 4
    Page 95
    Revision 2.0
    PN-SC02 (ICH)
    (3) Switch Settings
    The figure in the SWITCH NAME column and the position in   in the SETTING POSITION col-
    umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
     , the setting of the switch varies with the system concerned.
    Note 1:Set the groove on the switch knob to the desired switch position.
    Note 2:When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit
    card.
    Switch Settings 
    SWITCH
    NAMESWITCH
    NUMBERSETTING
    POSITIONFUNCTION CHECK
    SENS
    (Rotary SW)
    Note 14 - F Set the switch to match the AP Number (04 - 15) to be set by CM05.
    0 - 3 Not used
    MB (Toggle SW)
    Note 2UP For make-busy
    For normal operation
    SW0
    (Piano Key SW)1 Always set to OFF
    2 Always set to OFF
    3 Always set to OFF
    4Always set to ON
    AP NO.
    SW NO.10 04 05 06 07 08 09 11 12 13 14 15
    456 789ABCDEF
    ON
    DOWN
    ON
    OFF
    4
    3
    2
    1
    OFF
    OFF
    OFF
    ON 
    						
    							CHAPTER 4 ND-45504 (E)
    Pag e 96
    Revision 2.0
    PN-SC03 (ICH)
    PN-SC03 (ICH)
    1. Locations of Lamps, Switches, and Connectors 
    PN-SC03 (ICH) Card
    2. Lamp Indications
    Lamp Indications on ICH Card
    LAMP NAME COLOR FUNCTION
    RUN Green Flashes at 120 IPM while the card is operating normally.
    DOPE7 Green Lights when No.7 circuit D channel link is connected.
    DOPE6 Green Lights when No.6 circuit D channel link is connected.
    DOPE5 Green Lights when No.5 circuit D channel link is connected.
    DOPE4 Green Lights when No.4 circuit D channel link is connected.
    DOPE3 Green Lights when No.3 circuit D channel link is connected.
    DOPE2 Green Lights when No.2 circuit D channel link is connected.
    DOPE1 Green Lights when No.1 circuit D channel link is connected.
    DOPE0 Green Lights when No.0 circuit D channel link is connected.
    SENSE
    RUN
    MB
    DOPE7
    DOPE6
    DOPE5
    DOPE4
    DOPE3
    DOPE2
    DOPE1
    DOPE0 
    						
    							ND-45504 (E) CHAPTER 4
    Page 97
    Revision 2.0
    PN-SC03 (ICH)
    (3) Switch Settings
    The figure in the SWITCH NAME column and the position in    in the SETTING POSITION col-
    umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
    , the setting of the switch varies with the system concerned.
    Note 1:Set the groove on the switch knob to the intended switch position.
    Note 2:When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit
    card.
    Switch Settings on ICH Card
    SWITCH
    NAMESWITCH
    NUMBERSETTING
    POSITIONFUNCTION CHECK
    SENSE
    (Rotary SW)
    Note 14 ~ F Set the switch to match the AP Number (04 ~ 15) to be set by CM05.
    0 ~ 3 Not used
    MB (Toggle SW)
    Note 2UPFor make-busy
    For normal operation
    AP No.
    SW No.10 04 05 06 07 08 09 11 12 13 14 15
    4 5 6 78 9ABCDEF
    ON
    DOWN 
    						
    							CHAPTER 4 ND-45504 (E)
    Pag e 98
    Revision 2.0
    PN-SC03 (CSH)
    PN-SC03 (CSH)
    1. Locations of Lamps, Switches, and Connectors 
    PN-SC03 (CSH) Card
    SENSE
    RUN
    MB
    DOPE7
    DOPE6
    DOPE5
    DOPE4
    DOPE3
    DOPE2
    DOPE1
    DOPE0 
    						