ND-45504 (E) CHAPTER 4 Page 99 Revision 2.0 PN-SC03 (CSH) (2) Lamp Indications 3. Switch Settings The figure in the SWITCH NAME column and the position in in the SETTING POSITION col- umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. Note 1:Set the groove on the switch knob to the intended switch position. Note 2:When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit card. Lamp Indications on CSH Card LAMP NAME COLOR FUNCTION RUN Green Flashes at 120 IPM while the card is operating normally. DOPE7 Green Lights when No.7 circuit D channel link is connected. DOPE6 Green Lights when No.6 circuit D channel link is connected. DOPE5 Green Lights when No.5 circuit D channel link is connected. DOPE4 Green Lights when No.4 circuit D channel link is connected. DOPE3 Green Lights when No.3 circuit D channel link is connected. DOPE2 Green Lights when No.2 circuit D channel link is connected. DOPE1 Green Lights when No.1 circuit D channel link is connected. DOPE0 Green Lights when No.0 circuit D channel link is connected. Switch Settings on CSH Card SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SENSE (Rotary SW) Note 14 ~ F Set the switch to match the AP Number (04 ~ 15) to be set by CM05. 0 ~ 3 Not used MB (Toggle SW) Note 2UPFor make-busy For normal operation AP No. SW No.10 04 05 06 07 08 09 11 12 13 14 15 4 5 6 78 9ABCDEF ON DOWN
![](/img/blank.gif)
CHAPTER 4 ND-45504 (E) Page 100 Revision 2.0 4. LAMP INDICATIONS AND SWITCH SETTINGS OF LINE/TRUNK CIRCUIT CARDS Table 4-3 below shows the line/trunk circuit cards to be explained in this section. Table 4-3 Table of Line /Trunk Circuit Cards NAME (FUNCTIONAL NAME)EXISTENCE OF LAMPS X: PROVIDED — : NOT PROVIDED EXISTENCE OF SWITCHES X: PROVIDED — : NOT PROVIDED EXTRACTION/INSER- TION WITH POWER ON X: ALLOWED — : NOT ALLOWED REFERENCE PAGE PN-2AMPA (AMP) X— X101 PN-AUCA (AUC) X— X102 PN-CFTA (CFT) X— X103 PN-4COTB (COT) X— X104 PN-4COTG (COT) X— X105 PN-2DATA (DAT) XX X106 PN-DK00 (DK) — — X108 PN-4DITB (DIT) X— X109 PN-2DLCB (DLC) X— X110 PN-2DLCC (DLC) X— X111 PN-2DLCN (DLC) X— X112 PN-4DLCA (DLC) X— X113 PN-4DLCD (DLC) X— X114 PN-4DLCF (DLC) X— X115 PN-4DLCM (DLC) X— X116 PN-4DLCQ (DLC) X— X117 PN-2DPCB (DPC) XX X118 PN-2ILCA (ILC) XX X121 PN-4LCD/4LCD-A (LC) X— X124 PN-4LCJ (LC) X— X125 PN-M03 (M03) XX X126 PN-2ODTA (ODT) X— X129 PN-8RSTA (PBR) — — X130 PN-TNTA (TNT) — XX131 PN-2CSIA (CSI) X X X133
![](/img/blank.gif)
ND-45504 (E) CHAPTER 4 Page 101 Revision 2.0 PN-2AMPA (AMP) PN-2AMPA (AMP) 1. Locations of Lamps, Switches and Connectors PN-2AMPA (AMP) Card 2. Lamp Indications 3. Switch Settings This card has no switches. Lamp Indications LAMP NAME COLOR FUNCTION BL0, 1 Red• Remains lit when the corresponding circuit is in use. • Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the system data for this card is not assigned. BL1BL0
![](/img/blank.gif)
CHAPTER 4 ND-45504 (E) Page 102 Revision 2.0 PN-AUCA (AUC) PN-AUCA (AUC) 1. Locations of Lamps, Switches and Connectors PN-AUCA (AUC) Card 2. Lamp Indications 3. Switch Settings This card has no switches. Lamp Indications LAMP NAME COLOR FUNCTION BL0, 1 Red• Remains lit when the corresponding circuit is in use. • Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the system data for this card is not assigned. CN1 BL1 BL0
![](/img/blank.gif)
ND-45504 (E) CHAPTER 4 Page 103 Revision 2.0 PN-CFTA (CFT) PN-CFTA (CFT) 1. Locations of Lamps, Switches and Connectors PN-CFTA (CFT) Card 2. Lamp Indications 3. Switch Settings This card has no switches. Lamp Indications LAMP NAME COLOR FUNCTION BL0 Red• Remains lit when the card is in use. • Flashes (60 IPM) When the circuit on the card is in the make-busy state on the system data for this card is not assigned. BL1
![](/img/blank.gif)
CHAPTER 4 ND-45504 (E) Page 104 Revision 2.0 PN-4COTB (COT) PN-4COTB (COT) 1. Locations of Lamps, Switches and Connectors PN-4COTB (COT) Card 2. Lamp Indications 3. Switch Settings This card has no switches. Lamp Indications LAMP NAME COLOR FUNCTION BL0 - 3 Red• Remains lit when the corresponding circuit is in use. • Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the system data for this card is not assigned. CN1 BL3 BL0 BL2 BL1
![](/img/blank.gif)
ND-45504 (E) CHAPTER 4 Page 105 Revision 2.0 PN-4COTG (COT) PN-4COTG (COT) 1. Locations of Lamps, Switches and Connectors PN-4COTG (COT) Card 2. Lamp Indications 3. Switch Settings This card has no switches. Lamp Indications LAMP NAME COLOR FUNCTION BL0 - 3 Red• Remains lit when the corresponding circuit is in use. • Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the system data for this card is not assigned. CN1 BL3 BL0 BL2 BL1
![](/img/blank.gif)
CHAPTER 4 ND-45504 (E) Page 106 Revision 2.0 PN-2DATA (DAT) PN-2DATA (DAT) 1. Locations of Lamps, Switches and Connectors PN-2DATA (DAT) Card 2. Lamp Indications Lamp Indications LAMP NAME COLOR FUNCTION BL0, 1 Red• Remains lit when the corresponding circuit is in use. • Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the system data for this card is not assigned. BL0 BL1 SW
![](/img/blank.gif)
ND-45504 (E) CHAPTER 4 Page 107 Revision 2.0 PN-2DATA (DAT) (3) Switch Settings The figure in the SWITCH NAME column and the position in in the SETTING POSITION col- umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. Switch Settings SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SW (Piano Key SW)SW-0ONData write into the No.1 circuit is disabled. Data write into the No.1 circuit is enabled. SW-1ONData write into the No.1 circuit is disabled. Data write into the No.1 circuit is enabled. OFF ON SW1 SW0 OFF OFF
![](/img/blank.gif)
CHAPTER 4 ND-45504 (E) Page 108 Revision 2.0 PN-DK00 (DK) PN-DK00 (DK) 1. Locations of Lamps, Switches and Connectors PN-DK00 (DK) Card 2. Lamp Indications This card has no indicator lamps. 3. Switch Settings This card has no switches.