ND-45504 (E) CHAPTER 4 Page 75 Revision 2.0 PN-24DTA-A (DTI) PN-24DTA-A (DTI) 1. Location of Lamps, Switches, and Connectors PN-24DTA-A (DTI) Card 2. Lamp Indications Lamp Indications LAMP NAME COLOR FUNCTION RUN Green Flashes at 120 IPM while this card is operating normally. CRC Red Lights when detecting Cyclic Redundancy Checking (CRC) errors. PCM Red Lights when detecting PCM signal loss. FRM Red Lights when detecting a Frame Alignment signal loss. RMT Red Lights when receiving a Frame Alignment signal loss alarm from a distant office. AIS RedLights when a pattern of consecutive “1” is received. The distant office transmits this signal for a loop-back test. BL RedB channel status ON : More than 10 channels is busy OFF : All channels are idle Flash (60 IPM):Only one channel is busy Flash (120 IPM):2 through 10 channels are busy SENS RUN MB SW CRC PCM FRM RMT AIS BL JPS JPR1 JPR0 MAS AISS [When Card Issue No. is before 5A] SENS RUN MB SW CRC PCM FRM AIS RMT BL JPS JPR 1 JPR0 MAS AISS [When Card Issue No. is after 5B]
![](/img/blank.gif)
CHAPTER 4 ND-45504 (E) Pag e 76 Revision 2.0 PN-24DTA-A (DTI) (3) Switch Settings Switch Settings SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SENS (Rotary SW) Note 14 ~ F Set the switch to match the AP Number (04 ~ 15) to be set by CM05. 0 ~ 3Not used MB (Toggle SW) Note 2UP For make-busy For normal operation SW (Piano Key SW)1ONClock signal from a master office is sent to the PLO 0 in- put on the MP card. OFFClock signal from a master office is not sent to the PLO 0 input on the MP card. 2ONClock signal from a master office is sent to the PLO 1 in- put on the MP card. OFFClock signal from a master office is not sent to the PLO 1 input on the MP card. 3ONRemote loop-back For normal operation 4ONLocal loop-back (AIS send) For normal operation 5Set the equalizer according to the cable length between the PBX and the MDF. OFF 6 OFF 7 OFF 8 Always set to ON AP NO. SW NO.10 04 05 06 07 08 09 11 12 13 14 15 456 789ABCDEF ON DOWN ON OFF 4 3 2 1 5 6 7 8 OFF OFF ON SW-5 SW-6 SW-7 CABLE LENGTH ON ON ON 0 - 40 m ( 0 - 131.2 ft.) ON ON OFF 40 - 80 m (131.2 - 262.5 ft.) ON OFF ON 80 - 120 m (262.5 - 394 ft.) ON OFF OFF 120 - 160 m (394 - 525 ft.) OFF ON ON 160 - 200 m (525 - 656 ft.) OFF OFF OFF Signal is not sent ON ON ON
![](/img/blank.gif)
ND-45504 (E) CHAPTER 4 Page 77 Revision 2.0 PN-24DTA-A (DTI) The figure in the SWITCH NAME column and the position in in the SETTING POSITION col- umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. Note 1:Set the groove on the switch knob to the intended switch position. Note 2:When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit card. Switch Settings (Continued) SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK JPS (Jumper pin) Neutral grounding on the transmitting line is not provid- ed. Left Neutral grounding on the transmitting line is provided. JPR0 (Jumper pin) Right Neutral grounding on the receiving line is provided. Neutral grounding on the receiving line is not provided. JPR1 (Jumper pin) Right Line impedance : 110 ohms Line impedance : 100 ohms AISS (Jumper pin) AIS signal is sent out when make-busy or power on. Left AIS signal is not sent out when make-busy or power on. MAS (Jumper pin) Right When this card is used for factory testing. When this card is used for normal operation. Right Left Left Right Left
![](/img/blank.gif)
CHAPTER 4 ND-45504 (E) Pag e 78 Revision 2.0 PN-24DTA-A (DTI) Note 3: Set SW-1 and SW-2 as follows: Note 4:When the PBX is the master office, set the SW1-1 and SW1-2 on all the DTI cards mounted in PIM0 to “OFF”. DTI0 DTI1 DTI2 DTI3 DTI4 REMARKS SW- 1SW- 2SW- 1SW- 2SW- 1SW- 2SW- 1SW- 2SW- 1SW- 2 When one DTI is pro- vided.ON OFFThe MP card will receive the clock signal from DTI0 at its PLO0 input. When more than one DTI is provided.ON OFF OFF ON OFF OFF OFF OFF OFF OFFThe MP card will receive the clock signal from DTI0 at its PLO0 input, under normal condi- tions. Should a clock failure occur with DTI0, the MP card will switch to the PLO1 input which gets clock from DTI1.No. of DTI SW CONDITIONS
![](/img/blank.gif)
ND-45504 (E) CHAPTER 4 Addendum-001 Page 78-1 JULY, 1998 Revision 2.1PN-30DTC/30DTC-A (DTI) PN-30DTC/30DTC-A (DTI) 1. Locations of Lamps, Switches, and Connectors PN-30DTC/30DTC-A (DTI) Card SENS RUN MB PCM SW FRM MFR M RMT MRMT AIS BL JP JPS JPR
![](/img/blank.gif)
CHAPTER 4 ND-45504 (E) Page 78-2 Addendum-001 Revision 2.1 JULY, 1998 PN-30DTC/30DTC-A (DTI) 2. Lamp Indications Lamp Indications LAMP NAME COLOR FUNCTION RUN Green Flashes at 120 IPM when this card is normally operating. PCM Red Lights when detecting PCM signal loss. FRM Red Lights when detecting Frame Alignment signal loss. MFRM Red Lights when detecting Multi-Frame Alignment signal loss on time slot 16. RMT RedLights when receiving an alarm because Frame Alignment signal loss has been detected at the distant office. MRMT RedLights when receiving an alarm because Multi-Frame Alignment signal loss has been detected at the distant office. AIS RedLights when indicating that the pattern of consecutive “1” is being received. (The distant office transmits this signal for a loop-back test). BL Red B channel status ON : More than10 channels are busy OFF : All channels are idle Flash (60 IPM) : Only one channel is busy Flash (120 IPM) : 2 to 10 channels are busy
![](/img/blank.gif)
ND-45504 (E) CHAPTER 4 Addendum-001 Page 78-3 JULY, 1998 Revision 2.1PN-30DTC/30DTC-A (DTI) 3. Switch Settings Switch Settings SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SENS (Rotary SW) Note 14 ~ F Set the switch to match the AP Number (04-15) as set by CM05. 0 ~ 3 Not used MB (Toggle SW) Note 2UP For make-busy For normal operation SW (Piano Key SW)1 Note 3 ONClock signal from master office is sent to PLO 0 on the MP card. OFFClock signal from master office is not sent to PLO 0 on the MP card. 2 Note 3 ONClock signal from master office is sent to PLO 1 on the MP card. OFFClock signal from master office is not sent to PLO 1 on the MP card. 3ON Remote loop-back For normal operation 4ON Local loop-back (AIS send) For normal operation 5ON Transmission line cable: Coaxial (75 W) Note 4 Transmission line cable: Twisted-pair (120 W) 6 Always set to OFF 7 8 Always set to ON 0AP NO. SW NO.10 04 05 06 07 08 09 11 12 13 14 15 4 5 6 78 9ABCDEF ON DOWN ON OFF 4 3 2 1 5 6 7 8 OFF OFF OFF OFF OFF ON
![](/img/blank.gif)
CHAPTER 4 ND-45504 (E) Page 78-4 Addendum-001 Revision 2.1 JULY, 1998 PN-30DTC/30DTC-A (DTI) The figure in the SWITCH NAME column and the position in in the SETTING POSITION col- umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. Note 1:Set the groove on the switch knob to the intended switch position. Note 2:When the power is on, set the MB switch to ON (UP position) before plugging/unplugging the circuit card. JPS (Jumper pin)Balanced transmission (For twisted-pair cable) DOWNTA is grounded on the transmission line (For coaxial cable) Note 4 JPR (Jumper pin)Balanced transmission (For twisted-pair cable) DOWNRA is grounded on the transmission line (For coaxial cable) JP (Jumper pin) RIGHTLine impedance: 75 ohms (For coaxial cable) Note 4 Line impedance: 120 ohms (For twisted-pair cable) Switch Settings SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK UP UP LEFT
![](/img/blank.gif)
ND-45504 (E) CHAPTER 4 Addendum-001 Page 78-5 JULY, 1998 Revision 2.1PN-30DTC/30DTC-A (DTI) Note 3: Set SW-1 and SW-2 as follows. Note 4: Coaxial cable connection to the PN-30DTC/30DTC-A is not available in the U.S. DTI 0DTI 1DTI 2DTI 3 REMARKS SW-1 SW-2 SW-1 SW-2 SW-1 SW-2 SW-1 SW-2 When one DTI is provided. ON OFFThe MP card will receive the clock signal from DTI 0 at its PLO 0 input. When more than one DTI is provided.ON OFF OFF ON OFF OFF OFF OFFThe MP card will receive the clock signal from DTI 0 at its PLO 0 input, under normal conditions. Should a clock failure occur on DTI 0, the MP card will automatical- ly switch to the PLO 1 input, and so derive the clock from DTI 1. No. of DTI CONDITIONS SW
![](/img/blank.gif)
CHAPTER 4 ND-45504 (E) Page 78-6 Addendum-001 Revision 2.1 JULY, 1998 This page is for your notes.