    							ND-45504 (E) CHAPTER 4
    Page 79
    Revision 2.0
    PN-ME00 (EXTMEM)
    PN-ME00 (EXTMEM)
    1. Locations of Lamps, Switches, and Connectors
    PN-ME00 (EXTMEM) Card
    2. Lamp Indications
     Lamp Indications
    LAMP NAME COLOR FUNCTION
    RUN Green Flashes at 120 IPM while this circuit card is operating normally.
    WP Red Lights when the RAM is being accessed.
    BAT RedLights indicating the status (Write Protect Switch status and the battery voltage 
    status) of the SRAM card on this circuit card.
    JP2
    SENS
    RUN
    MB
    WP
    BATJP0
    CN0
    LAMP STATUSWRITE PROTECT
    SWITCH STATUSBATTERY VOLTAGE
    STATUS
    On Protect On OK
    Flash (60 IPM) Protect Off Needs to be replaced
    Flash (120 IPM) Protect On Needs to be replaced
    Off Protect Off OK 
    						
    							CHAPTER 4 ND-45504 (E)
    Pag e 80
    Revision 2.0
    PN-ME00 (EXTMEM)
    nMounting the SRAM Card
    ¬Slide the lock switch downward (Lock Release), then remove the battery case from the SRAM card.
    ­Mount the battery on the battery case, then insert the battery case into the SRAM card.
    ®Slide the lock switch upward (Lock).
    ¯Mount the SRAM card in the PN-ME00 card.
    °Slide the write protect switch downward (Active).
    Front View of the SRAM Card How to Handle the SRAM Card
    BATTERY CASE LOCK SWITCH
    WRITE PROTECT SWITCH
    UPWARD DOWNWARD
    LOCK LOCK RELEASE
    ACTIVEPROTECT
    L O C K
    FRONT 
    						
    							ND-45504 (E) CHAPTER 4
    Page 81
    Revision 2.0
    PN-ME00 (EXTMEM)
    nRemoving the SRAM Card
    ÀPush the card slot bar of the PN-ME00 card.
    ÁRemove the SRAM card.
    Removing the SRAM Card
    nReplacing the SRAM Battery
    ÀSlide the lock switch downward (Lock Release), then remove the battery case from the SRAM card.
    ÁReplace the battery, then insert the battery case into the SRAM card.
    ÂSlide the lock switch upward (Lock).
    CAUTION
    To prevent loss of memory on an active system, the battery must be replaced when the SRAM card is installed on
    the PN-ME00, and the PN-ME00 is installed in the system. Also, power to the system must be “ON”.
    SRAM PUSH
    PN-ME00 
    						
    							CHAPTER 4 ND-45504 (E)
    Pag e 82
    Revision 2.0
    PN-ME00 (EXTMEM)
    Replacing the SRAM Battery
    PN-ME00
    REMOVE THE 
    BATTERY CASE
    LITHIUM BATTERY: 
    BR2325 OR CR2325 
    						
    							ND-45504 (E) CHAPTER 4
    Page 83
    Revision 2.0
    PN-ME00 (EXTMEM)
    (3) Switch Settings
    The figure in the SWITCH NAME column and the position in    in the SETTING POSITION col-
    umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
    , the setting of the switch varies with the system concerned.
    Note 1:Set the groove on the switch knob to the desired switch position.
    Note 2:When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit
    card.
    Note 3:Do not touch the JP0. If the jumper is pulled off, the data in the memory of the ME00 card is cleared.
    Switch Settings
    SWITCH NAMESWITCH 
    NUMBERSETTING
    POSITIONFUNCTION CHECK
    SENSE
    (Rotary SW)
    Note 14 - F Set the switch to match the AP Number (04 - 15) to be set by 
    CM05.
    0 - 3 Not used
    MB(Toggle SW)
    Note 2UP For make-busy
    For normal operation
    JP0 (Jumper pin)
    Note 3For normal operation
    JP2 (Jumper pin) For normal operation
    AP NO.
    SW NO.10 04 05 06 07 08 09 11 12 13 14 15
    4 5 6 78 9ABCDEF
    ON
    DOWN
    Fro nt
    UP
    Fron t
    UP 
    						
    							CHAPTER 4 ND-45504 (E)
    Pag e 84
    Revision 2.0
    PN-4RSTB (MFR)
    PN-4RSTB (MFR)
    1. Locations of Lamps, Switches and Connectors
    PN-4RSTB (MFR) Card
    2. Lamp Indications
    Lamp Indications
    LAMP NAME COLOR FUNCTION
    RUN Green Flashes at 120 IPM while the circuit card is operating normally.
    OPE Red• Lights when the corresponding circuit is in use.
    • Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the system
    data for this card is not assigned.
    SENS
    RUN
    MB
    OPE3
    SW
    OPE2
    OPE1
    OPE0 
    						
    							ND-45504 (E) CHAPTER 4
    Page 85
    Revision 2.0
    PN-4RSTB (MFR)
    (3) Switch Settings
    Note 1:Set the groove on the switch knob onto the desired switch position.
    Note 2:When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit
    card.
    Switch Settings
    SWITCH
    NAMESWITCH
    NUMBERSETTING
    POSITIONFUNCTION CHECK
    SENS 
    (Rotary SW)
    Note 1
    4 - FSet the switch to match the AP Number (04 - 15) to be set by CM05.
    0 - 3 Not used
    MB (Toggle SW)
    Note 2UP For make-busy
    For normal operation
    SW
    (Piano Key SW)1ON For make-busy No. 0 circuit
    For normal operation 
    2ON For make-busy No. 1 circuit
    For normal operation 
    3ON For make-busy No. 2 circuit
    For normal operation
    4ON For make-busy No. 2 circuit
    For normal operation
    5
    Not used
    6
    7
    8 Always set to ON
    AP NO.
    SW NO.10 04 05 06 07 08 09 11 12 13 14 15
    456 789ABCDEF
    ON
    DOWN
    ON
    OFF
    4
    3
    2
    1
    5 6
    7
    8
    OFF
    OFF
    OFF
    OFF
    OFF
    OFF
    OFF
    ON 
    						
    							CHAPTER 4 ND-45504 (E)
    Pag e 86
    Revision 2.0
    PN-4RSTC (CIR)
    PN-4RSTC (CIR)
    1. Locations of Lamps, Switches and Connectors
    PN-4RSTC (CIR) Card
    2. Lamp Indications
    Lamp Indications
    LAMP NAME COLOR FUNCTION
    RUN Green Flashes at 120 IPM while the circuit card is operating normally.
    BL0-3 Red Lights when receiving a CALLER ID (CLASS SM) signal.
    SENSE
    RUN
    MB
    BL3
    SW1
    BL2
    BL1
    BL0
    JP0 
    						
    							ND-45504 (E) CHAPTER 4
    Page 87
    Revision 2.0
    PN-4RSTC (CIR)
    (3) Switch Settings
    Note 1:Set the groove on the switch knob onto the desired switch position.
    Note 2:When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit
    card.
    Switch Settings
    SWITCH
    NAMESWITCH
    NUMBERSETTING
    POSITIONFUNCTION CHECK
    SENSE
    (Rotary SW)
    Note 14 - F Set the switch to match the AP Number (04 - 15) to be set by CM05.
    0 - 3
    Not used
    MB(Toggle SW)
    Note 2UP For make-busy
    For normal operation
    SW1
    (Piano Key SW)1ON For make-busy No. 0 circuit
    For normal operation
    2ON For make-busy No. 1 circuit
    For normal operation
    3ON For make-busy No. 2 circuit
    For normal operation
    4ON For make-busy No. 3 circuit
    For normal operation
    JP0 (Jumper pin)
    For normal operation
    AP NO.
    SW NO.10 04 05 06 07 08 09 11 12 13 14 15
    4 5 6 78 9ABCDEF
    ON
    DOWN
    ON
    OFF
    4
    3
    2
    1
    OFF
    OFF
    OFF
    OFF
    Right 
    						
    							CHAPTER 4 ND-45504 (E)
    Pag e 88
    Revision 2.0
    PN-SC00 (CCH)
    PN-SC00 (CCH)
    1. Locations of Lamps, Switches and Connectors
    PN-SC00 (CCH) Card
    2. Lamp Indications
    Lamp Indications
    LAMP NAME COLOR FUNCTION
    RUN Green Flashes at 120 IPM while this card is operating normally.
    LC GreenLights when communications are normally ongoing with the common signalling channel 
    data links connected.
    LPB Green Lights when a loop-back test is in progress.
    SENS
    RUN
    MB
    SW0
    LC
    RS
    LPB SW1 
    						