Page 191
NEAX2400 IPX Hotel Feature Programming Manual NDA-24304, Issue 1Page 177 Maid Status M-22 12 ARTDAssign route data of the trunk interfacing with the announcement unit. (OSGS = 2, TCL = 4, LSG = 5 should be set.) 13 ATRK Assign the trunk interfacing with announcement unit. 14 MBTK Release the Make Busy of the trunk assigned in ATRK. 15 ARSCRelease the call restrictions between the RSC of the station accessing the announcement unit and the route of the trunk assigned in ATRK. (RRI = 2, 3) 16 AAEDAssign the...
Page 192
NEAX2400 IPX Hotel Feature Programming ManualPage 178NDA-24304, Issue 1 M-51 Manual Switching Of C.O. Incoming Call Destination M-51Manual Switching Of C.O. Incoming Call Destination General Description This feature allows the Console operator to manually change the termination point of a specific group of trunks. Trunks that normally are used as DIT trunks may be changed to terminate at the Console. Operating Procedure To change the termination of DIT trunks from stations to the Console 1. Press...
Page 193
NEAX2400 IPX Hotel Feature Programming Manual NDA-24304, Issue 1Page 179 Maid Status - Answerback M-68 M-68Maid Status - Answerback General Description This feature allows a maid or other hotel personnel to receive answerback acknowledgment from the PMS (Property Management System) computer when MAID STATUS has been changed using Guest room station or Special Administration Station telephones. Operating Procedure Service setting from a Guest room station by a maid or repairman 1. Lift handset. Hear dial...
Page 194
NEAX2400 IPX Hotel Feature Programming ManualPage 180NDA-24304, Issue 1 M-68 Maid Status - Answerback Assignment Procedure STEP CMND BIT EXPLANATION 1SYS1 ASYD INDEX 163b 0Over Time Call timer. b 1 b2Over Time Call 0/1 = Out/In Service b 3Over Time Call indication 0/1 = On Console/Hotel Printer b 4Step Call from Guest Station is allowed 0/1 = Out Service/In b 5Tone type for Maid Dialing b 6b5b6b5 0 0 = SST 1 0 = – 0 1 = Announcement 1 1 = Music on Hold b6 b7Start time of Automatic Wake-Up Call 0/1: On...
Page 195
NEAX2400 IPX Hotel Feature Programming Manual NDA-24304, Issue 1Page 181 Maid Status - Answerback M-68 Note:Room Cutoff (RSC 13) Do Not Disturb (RSC 14) Room Cutoff and Do Not Disturb (RSC 15) 3SYS1 ASYD INDEX 170b 0Room status data (b2,b1,b0)tobesetatthetimeofCheckout b 2b1b0b2b1b0000=– 010=Cleaned 0 0 1 = To be Cleaned 0 1 1 = Ready for Occupancy Note: Do not assign other data. b1 b2 b3Restriction at the time of Do not Disturb and Room Cut-Off 0/1 = Room Status Memory/Change of RSCNote b 4Timing Start...
Page 196
NEAX2400 IPX Hotel Feature Programming ManualPage 182NDA-24304, Issue 1 O-6 Off-hook Alarm O-6Off-hook Alarm General Description The OFF-HOOK ALARM feature is intended for emergency alert situations. A station user who remains off-hook without dialing for longer than 30 seconds is automatically routed to theEMGkey on the Console or to a predesignated station. Operating Procedure 1. Station user goes off hook. After 30 seconds, a call is routed to theEMGkey on the console or to a predetermined station. 2....
Page 197
NEAX2400 IPX Hotel Feature Programming Manual NDA-24304, Issue 1Page 183 Off-hook Alarm O-6 Assignment Procedure When the Off-Hook Alarm termination is a Console: STEP CMND BIT EXPLANATION 1SYS1 ASYD INDEX 6 Noteb 0Special Transmitting Tone When Using Sender (Station) 0/1 = Not Required/Required (used with LCR/Speed Calling, etc.) b 1Not used b 2Special Transmitting Tone When Using Sender (ATT) 0/1 = Not Required/Required (used with LCR/Speed Calling, etc.) b 3Not used b 4 Assign ATT Pattern 1 or 2....
Page 198
NEAX2400 IPX Hotel Feature Programming ManualPage 184NDA-24304, Issue 1 O-6 Off-hook Alarm Note:This data is required for sending Howler Tone from Hotel Attendant. Refer to SERVICE CONDITIONS. When the Off-Hook Alarm destination is a specific station: 3SYS1 ASYD INDEX 168b 0Group Announcement Service through PMS 0/1 = Out/In Service b 1Audit Reports (for Hotel system) 0/1 = Out/In Service b 2Not used b 3 b4Off-Hook Alarm (service) 0/1 = Out/In Service b 5Destination for Off-Hook Alarm Termination 0/1 =...
Page 199
NEAX2400 IPX Hotel Feature Programming Manual NDA-24304, Issue 1Page 185 Off-hook Alarm O-6 4ASIDAssign the connection destination to the above GN. F: Off-Hook Alarm GN: Group Number assigned in ASGD S/A: Special Station (Assign S.) SSTN: Terminated Special Station Number 5ATNRPermit the connection between the special station number tenant and the tenant of the terminating Off-Hook Alarm station. STEP CMND EXPLANATION
Page 200
NEAX2400 IPX Hotel Feature Programming ManualPage 186NDA-24304, Issue 1 O-9 Overtime Call O-9Overtime Call General Description The OVERTIME CALL feature permits the NEAX2400 IPX to measure the length of all outgoing calls, and to print a message on the hotel printer or alert the Console that the call has exceeded a predetermined time. Operating Procedure If the hotel printer is to receive this information, no manual operation is required. To operate from the Console 1. The OT lamp flashes and an incoming...