Page 231

NEAX2400 IPX Hotel Feature Programming Manual
NDA-24304, Issue 1Page 217
Screening S-32
2SYS1
ASYD
INDEX
161b
0Don’t Disturb Override key on Console
0/1 = Out/In Service
b
1Message Waiting Lamp in Service
0/1 = Out/In Service
b
2Language Service
0/1 = Out/In Service
b
3Screening Service
0/1 = Out/In Service
b
4Not used
b
5DSS (Direct Station Section) Keys on Console
0/1 = Out/In service
b
6Timing Start using “#” Code
0/1 = Ineffective/Effective
b
7Timing Start using “*” Code
0/1 = Ineffective/Effective...

Page 232

NEAX2400 IPX Hotel Feature Programming ManualPage 218NDA-24304, Issue 1
S-49 Service Call Routing
S-49Service Call Routing
General Description
The SERVICE CALL ROUTING feature allows several extensions to be assigned the same number with different
terminations by differentiating between a main building and annex, or between floor numbers. This makes it
possible to set up service stations that are assigned the same number at several places in the hotel.
Operating Procedure
To call a service station
1....

Page 233

NEAX2400 IPX Hotel Feature Programming Manual
NDA-24304, Issue 1Page 219
Secretarial Service - Guest Station S-74
S-74Secretarial Service - Guest Station
General Description
This feature allows the Console to temporarily set two or more Guest stations to operate in a boss/secretary
arrangement. All calls to the boss are diverted to the secretary. The secretary may screen the calls and then transfer
the call to the boss or just take messages.
Operating Procedure
To set SECRETARIAL SERVICE - GUEST STATION...

Page 234

NEAX2400 IPX Hotel Feature Programming ManualPage 220NDA-24304, Issue 1
S-74 Secretarial Service - Guest Station
Operating Procedure (cont’d)
2. Dials the secretary’s station number. The display changes to display the secretary’s station number:
3. Press theENTERkey. The display changes as follows:
4. Press theENTERkey. The display changes as follows:
5. Press theEXITkey.
To call the Secretary Station from the Boss’ Station
1. Boss’ station lifts the handset. Boss’ Station receives dial tone.
2. Boss’...

Page 235

NEAX2400 IPX Hotel Feature Programming Manual
NDA-24304, Issue 1Page 221
Secretarial Service - Guest Station S-74
Service Conditions (cont’d)
2. The Console Check-In/Checkout keys are replaced by the Secretary Service Set and Secretary Service
Reset keys (depending on system data).
Figure 14 Check-In/Checkout Keys Replaced by Secretary Service Set/Reset (SCS, SCR)
3. The attendant is unable to originate a call directly to the boss.
4. Only Guest can be assigned this feature.
5. Setting of secretarial...

Page 236

NEAX2400 IPX Hotel Feature Programming ManualPage 222NDA-24304, Issue 1
S-75 Suite Room Service
S-75Suite Room Service
General Description
The SUITE ROOM SERVICE feature allows up to four analog stations to serve one suite room. Each telephone will
have its own station number. One station is designated as the primary station. When the primary station is called,
any secondary station in the suite may answer.
Operating Procedure
To answer a call
1. When a call is directed to the primary station, all...

Page 237

NEAX2400 IPX Hotel Feature Programming Manual
NDA-24304, Issue 1Page 223
Suite Room Service S-75
Service Conditions (cont’d)
b.) MESSAGE WAITING [M-6] - This feature is set or cancelled against the primary station or
phantom number. When set, all suite room stations will display the MESSAGE WAITING [M-6]
indication.
c.) AUTOMATIC WAKE-UP [A-10] - This feature is set or cancelled against the primary station.
When the wake-up call arrives, it will ring all suite room phones.
d.) DO NOT DISTURB [D-11] and...

Page 238

NEAX2400 IPX Hotel Feature Programming ManualPage 224NDA-24304, Issue 1
S-75 Suite Room Service
Service Conditions (cont’d)
e.) If a primary station is busy, an incoming call to the primary will, depending on the system
parameters, allow one of the following:
 Ringing idle secondary stations.
 The caller hears busy tone.
f.) For originating a call, one of several lines may be selected.
g.) The maximum number of multiple lines that can be set to a D
termis four.
20. When a few Dterms and a few analog...

Page 239

NEAX2400 IPX Hotel Feature Programming Manual
NDA-24304, Issue 1Page 225
Suite Room Service S-75
Assignment Procedure
STEP CMND BIT EXPLANATION
1AHSY
INDEX
111b
0Fixed Data
b
1
b2Restriction for hooking when an outgoing C.O. line call has originated from a suite room
0/1 = Restriction/No Restriction
b
3Setting of Message Registration Data to be sent out to the PMS
b
4b3
0 0 = The pilot number is sent out in the case of Suite Room; the Main Room Station
Number is sent out in the case of Connecting Room.
0...

Page 240

NEAX2400 IPX Hotel Feature Programming ManualPage 226NDA-24304, Issue 1
S-75 Suite Room Service
Note:To skip data entry, press the Enter key to step to the next data entry field.
3AHSY
INDEX
189b
0
Not used b
1
b2
b3
b4
b5
Suite Room Individual Station Calling
0 = A Suite Room individual station can be called from a Guest Station,
Administration Station, and Console.
1 = A Suite Room individual station can be called from a Special Administration
Station and Console.
b
6
Ringing for Connecting Room...