Home > NEC > Communications System > NEC Neax 2400 Ipx Hotel Feature Programming Manual

NEC Neax 2400 Ipx Hotel Feature Programming Manual

Here you can view all the pages of manual NEC Neax 2400 Ipx Hotel Feature Programming Manual. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 211

NEAX2400 IPX Hotel Feature Programming Manual
NDA-24304, Issue 1Page 197
PMS Interface P-29
Service Conditions (cont’d)
3. Message format:
Note:The Block Check Code is for the Longitudinal Redundancy Check.
On detecting STX, the computation starts (STX is excluded).
On detecting ETX, the computation ends (ETX is included).
4. Data format and contents of TEXT are in conformity with Bell System Voice Communications Technical
Reference Publication No. 42707, PMS Data Link Interface Specifications. (Details...

Page 212

NEAX2400 IPX Hotel Feature Programming ManualPage 198NDA-24304, Issue 1
P-29 PMS Interface
3SYS1
ASYD
INDEX
172b
0Message Waiting Information
Data transfer to/from PMS
when executing the service.
0/1=Nottobeexecuted/Tobe
executed b
1Message Registration
b
2Do Not Disturb, Room Cutoff
b
3Room Status
b
4Automatic Wake-Up, Group Announcement
b
5Room Change, Room Swap
b
6Room Data Change
b
7Not used
4SYS1
ASYD
INDEXES
190 & 191
Noteb
0I/O = Designation of PMS Port (for Line No. 2/3)
b
2b1b0b2b1b0
00 0=Port0...

Page 213

NEAX2400 IPX Hotel Feature Programming Manual
NDA-24304, Issue 1Page 199
PMS Interface P-29
Note:INDEX 190 and 191 should be assigned when the following Service features are required:
Directory Assistance Interface [D-88]
Guest Information Display - Console [G -8]
Guest Information Display - PMS Terminal [G-9]
Maid Status Answer Back [M-68]
For details, refer to the ASSIGNMENT PROCEDURE for the above service features. The different port
numbers should be entered into INDEX 10, INDEX 190, and INDEX 191....

Page 214

NEAX2400 IPX Hotel Feature Programming ManualPage 200NDA-24304, Issue 1
P-29 PMS Interface
133 Message Waiting Lamp - On
For controlling message waiting lamp of Guest
station
4 Message Waiting Lamp - Off
142 Call Detail DataThe following data about the calls originated from
Guest stations and administration station are
provided:
StationNumber
 RT No./Trunk No.
 Called Number (maximum of 16 digits)
CallStartTime
 Call Duration
 Number of Call Metering
KindofCall
6 Call Detail DataThe following data...

Page 215

NEAX2400 IPX Hotel Feature Programming Manual
NDA-24304, Issue 1Page 201
PMS Interface P-29
172Room Data Image - Room Data
ReportWhen the room data has been requested from the
PMS, the following room data reported/
exchanged:
StationNumber
 Out/Stay (Vacant/Occupied)
 Message Lamp
 Restriction Level 4Room Data Image - Room Data
Exchanged
6Room Data Image - Room Data
ReportWhen the room data has been requested from the
PMS, the following room data and above room
data reported/exchanged:
 Room Stay
...

Page 216

NEAX2400 IPX Hotel Feature Programming ManualPage 202NDA-24304, Issue 1
P-29 PMS Interface
511 Maid Status - Guest Room 1
ThesetextsareusedwithMaidStatusAnswer-
Back System. When Maid Status Answer Back
Access Code has been dialed via Guest/admi.
station the following data is sent to PMS:
Stations Number
Maid Identification Number
LENs (Line Equipment Number)
The kind of text information to be used depends
on the software at the PMS side. 2 Maid Status - Guest Room 2
3 Maid Status - Guest Room 3
4 Maid...

Page 217

NEAX2400 IPX Hotel Feature Programming Manual
NDA-24304, Issue 1Page 203
Paging Console P-34
P-34Paging Console
General Description
The PAGING CONSOLE feature allows a Console operator to transfer an incoming call to a PAGING CONSOLE
when the Guest is not in his or her room. The PAGING CONSOLE operator pages the Guest through the hotel public
address system, requesting him or her to dial a special number from a nearby telephone. When the Guest calls, the
PAGING CONSOLE operator connects the Guest to the...

Page 218

NEAX2400 IPX Hotel Feature Programming ManualPage 204NDA-24304, Issue 1
P-34 Paging Console
Assignment Procedure
STEP CMND BIT EXPLANATION
1SYS1
ASYD
INDEX 73b
0Type of Paging Service
b
1b0b1b0
0 0 =No Answer 1 0 = Delay
0 1 =None Delay 1 1 = Delay with Paging Transfer b1
b2
Radio Page Number
(SIM/IMG = 2 Digits only)
0/1=2digits/3digits
b
3Paging Cancel Code
0/1 = Individual Paging Route Codes/Common to all Paging Routes
b
4Radio Paging - station number is automatically sent.
0/1 = Out/In Service
b...

Page 219

NEAX2400 IPX Hotel Feature Programming Manual
NDA-24304, Issue 1Page 205
Paging Console P-34
4AHSY
INDEX
104b
0Miscellaneous Timer Class (MTC) is to be assigned a
valuefrom0HextoFHex(0-15).Paging Console
Automatic Recall Timer:
Timer Value Setting is
MTC x TC sec.
Note:
When this data
is 00 Hex, ROM
data is
automatically
set to 3 min.
b1
b2
b3
b4Timer Class Length (TCL) is to be assigned one of the
following values:
b
6b5b4b6b5b4
000=- 100=64 sec.
001=8sec. 101=-
0 1 0= 16 sec. 1 1 0 = -
0 1 1= 32 sec. 1...

Page 220

NEAX2400 IPX Hotel Feature Programming ManualPage 206NDA-24304, Issue 1
R-9 Room Cutoff
R-9Room Cutoff
General Description
This feature allows the Console, PMS terminal, or Front Desk Terminal to temporarily restrict outgoing CO calls
from Guest room telephones while the Guests are away.
Operating Procedure
To set ROOM CUTOFF from Console or Front Desk Terminal
1. Press theRCS(set) key. The associated lamp illuminates.
2. Dial the station number. The console displays the station number.
3. Press...
Start reading NEC Neax 2400 Ipx Hotel Feature Programming Manual

Related Manuals for NEC Neax 2400 Ipx Hotel Feature Programming Manual

All NEC manuals