NEAX2400 IPX Feature Programming ManualPage 268NDA-24297, Issue 1 C-169 Consultation Hold Release Service Conditions (cont’d) 4. A station assigned EMERGENCY CALL [3-11] (SFI = 24) cannot be applied to operating station of this feature. 5. The DISC key used for this feature can be assigned by FKY = 131 of AKYD command. 6. When an analog station uses this feature while in ADD-ON CONFERENCE-8 PARTY [A-121], assign System Data 1 Index 803 Bit2 = 1 also. However, the analog station assigned SFI 131 = 1...
Page 312
NEAX2400 IPX Feature Programming Manual NDA-24297, Issue 1Page 269 Dial Access To Attendant D-2 D-2 Dial Access To Attendant General Description This feature allows a user to access the ATTENDANT CONSOLE [A-3] by dialing the operator call code. Operating Procedure To access the Attendant 1. The user dials the operator call code; receives ringback tone. 2. The ATND lamp for the INCOMING CALL IDENTIFICATION [I-2] flashes; Attendant answers the call. Service Conditions 1. The operator call code will be a...
Page 313
NEAX2400 IPX Feature Programming ManualPage 270NDA-24297, Issue 1 D-2 Dial Access To Attendant FCCS Programming This data setting describes only the additional or replacement commands used to activate FCCS services. When used as an FCCS feature, these commands replace the non-network commands (for example, AAED is replaced by AAEDN). Note that the data setting for FCCS service varies depending on the node. STEP 1:ASPAL- This data must be assigned to the node calling the attendant. SRV: SSC SID:...
Page 314
NEAX2400 IPX Feature Programming Manual NDA-24297, Issue 1Page 271 Dictation Access D-3 D-3 Dictation Access General Description This feature permits users dial access to customer provided dictation equipment, and in some instances allows them to maintain telephone dial control of normal dictation system features. Operating Procedure 1. Dial the DICTATION ACCESS code. 2. Proceed according to the dictation instructions provided by your organization. Service Conditions 1. One trunk circuit is required for...
Page 315
NEAX2400 IPX Feature Programming ManualPage 272NDA-24297, Issue 1 D-3 Dictation Access Interactions (cont’d) 4. If the station side is used to connect DICTATION ACCESS, STATION HUNTING [S-7, 8, 9] will provide capabilities to connect multiple dictation machines to the system. Programming STEP 1:ANPD- Reserve a number level for station access. Assign for Normal (N) and Hooking (H). Assign NND in accordance with a predetermined numbering plan. STEP 2:ASPA- Assign an access code to the DICTATION ACCESS...
Page 316
NEAX2400 IPX Feature Programming Manual NDA-24297, Issue 1Page 273 Digital Display - Station D-5 D-5 Digital Display - Station General Description This feature provides the Attendant with a visual display (via the ATTENDANT CONSOLE [A-3]) of the telephone number, its Trunk Route Restriction, CLASS OF SERVICE - INDIVIDUAL [C-15] and TENANT [T-12] number during Attendant-to-station connection. Operating Procedure The DIGITAL DISPLAY STATION is automatically activated whenever the Attendant answers an...
Page 317
NEAX2400 IPX Feature Programming ManualPage 274NDA-24297, Issue 1 D-5 Digital Display - Station Service Conditions (cont’d) Example 2: 2-digit TENANT [T-12] number, 4-digit telephone number. Example 3: 2-digit Trunk Route Restriction Class, 4-digit telephone number. Example 4: Single digit TENANT [T-12] number, 5-digit telephone number. Example 5: Single digit Trunk Route Restriction Class, 5-digit telephone number. Example 6: When 5-digit station numbering is used, only the telephone number is...
Page 318
NEAX2400 IPX Feature Programming Manual NDA-24297, Issue 1Page 275 Digital Display - Trunk D-6 D-6 Digital Display - Trunk General Description This feature provides the Attendant with a visual indication of incoming and outgoing trunk calls on the ATTENDANT CONSOLE [A-3]. Trunk identification number, trunk route number, and TENANT [T-12] number, or Central Office trunk code, are displayed in a numerical readout. Operating Procedure The DIGITAL DISPLAY TRUNK is automatically activated whenever the...
Page 319
NEAX2400 IPX Feature Programming ManualPage 276NDA-24297, Issue 1 D-6 Digital Display - Trunk Service Conditions (cont’d) d.) an outgoing C.O. (DOD, WATS, FX) type call. e.) an outgoing TIE Line call or re-enters a held trunk call. 7. An Attendant Console also indicates the C.O. code assigned by system data at each node in the FCCS network. Programming STEP 1:ASYD- System Data 1, Index 68, Bit 1. Type of INDIVIDUAL TRUNK ACCESS, 0/1: Route and Trunk Number/Central Office Code. Note:If System Data 1,...
Page 320
NEAX2400 IPX Feature Programming Manual NDA-24297, Issue 1Page 277 Direct-In Termination (DIT) D-7 D-7 Direct-In Termination (DIT) General Description This feature automatically routes incoming public network calls directly to a pre-selected station without Attendant assistance. The call can then be processed by the called party. THREE-WAY CALLING [T-2], CALL TRANSFER [C-10], etc., are handled in the same manner as any normal trunk call. Operating Procedure The calling party, outside the system, dials...