NEC Neax 2400 Imx Hotel Feature Programming Manual
Here you can view all the pages of manual NEC Neax 2400 Imx Hotel Feature Programming Manual. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 131
NEAX2400 IMX Hotel Feature Programming Manual ND-70284 (E), Issue 2 Page 117 Dterm With Hotel Function D-105D Operating Procedure (cont’d) For ROOM STATUS [R-10] Idle Condition: Connected to a guest station: Step Action Result 1 Press the STS key.The LCD shows the feature abbreviation. 2Enter the guest station number. 3Press the ENT key.The MESSAGE WAITING [M-6] set, CHECK-IN/CHECKOUT [C-23] set, DO NOT DISTURB [D-11] set, ROOM CUTOFF [R-9] set LEDs will illuminate if these services have been set...
Page 132
NEAX2400 IMX Hotel Feature Programming Manual Page 118ND-70284 (E), Issue 2 D-105D Dterm With Hotel Function Operating Procedure (cont’d) Figure 6 Example of 16-Button Dterm on a Front Desk Console For AUDIT REPORTS [A-26] Idle Condition only: Service Conditions 1. A maximum of 32 Front Desk Terminals per Module Group (MG) may be assigned. 2. 16-button or 24-button D terms shall be used as a Front Desk Terminal. 3. Only Special Administration Stations may be Front Desk Terminals. 4. MESSAGE WAITING...
Page 133
NEAX2400 IMX Hotel Feature Programming Manual ND-70284 (E), Issue 2 Page 119 Dterm With Hotel Function D-105D Service Conditions (cont’d) 8. The service feature abbreviations shown on the 16-button or 24-button Dterm LCD are shown in Table 5: Assignment Procedure Table 5 Standard Service Abbreviations on Dterm Feature Set/Activate Reset AUDIT REPORTS [A-26] AUD — AUTOMATIC WAKE-UP [A-10] WUS WUR CHECK-IN/CHECKOUT [C-23] C/I C/O DO NOT DISTURB [D-11] DDS DDR MESSAGE WAITING [M-6] MWS MWR ROOM CUTOFF...
Page 134
NEAX2400 IMX Hotel Feature Programming Manual Page 120ND-70284 (E), Issue 2 D-107 Direct Data Entry – Station D-107 Direct Data Entry – Station General Description This feature allows a maid or other hotel personnel to enter numeric data to the Property Management System (PMS) computer, using the guest room station for entry through dial operation. Operating Procedure Note: If a Dterm is used for a guest station, the LCD displays as shown below: Service Conditions 1. This feature is activated only...
Page 135
NEAX2400 IMX Hotel Feature Programming Manual ND-70284 (E), Issue 2 Page 121 Double Suite Room D-150 D-150 Double Suite Room General Description This service allows two suite rooms (single suite rooms) to be connected as a double suite room. Maximum eight stations can be called simultaneously. Figure 7 Example of Single/Double Suite Room Operating Procedure To call a double suite room: Service Conditions 1. The single suite rooms must be assigned prior to activating this service. 2. The telephone...
Page 136
NEAX2400 IMX Hotel Feature Programming Manual Page 122ND-70284 (E), Issue 2 D-150 Double Suite Room Service Conditions (cont’d) c.) When the individual telephone number of the double suite room is called, only that telephone rings. 4. When all the telephones of the double suite room are rung simultaneously, the call is connected to the first telephone which answers. When the call is answered, other telephones stop ringing. 5. Each of the telephones in the double suite room can originate the call...
Page 137
NEAX2400 IMX Hotel Feature Programming Manual ND-70284 (E), Issue 2 Page 123 Double Suite Room D-150 Assignment Procedure See SUITE ROOM SERVICE [S-75] for initial programming. STEP CMND BIT EXPLANATION 1AHSY INDEX 111b 0Fixed Data b 1 b2Restriction for hooking when an outgoing C.O. line call has originated from a suite room 0/1 = Restriction/No Restriction b 3Setting of Message Registration Data to be sent out to the PMS b 4b3 0 0 : The pilot number is sent out for the Suite Room; the Main Room...
Page 138
NEAX2400 IMX Hotel Feature Programming Manual Page 124ND-70284 (E), Issue 2 D-150 Double Suite Room 4AHSY INDEX 189b 0 Not used b 1 b2 b3 b4 b5 Calling an Individual Suite Room Station Calling 0 An individual Suite Room Station can be called from a Guest Station, Administration Station, and Console. 1 An individual Suite Room Station can be called from a Special Administration Station and Console. b 6 Ringing at the time of general calling in the Connecting Room or Suite Room Stations 0 Ringing all...
Page 139
NEAX2400 IMX Hotel Feature Programming Manual ND-70284 (E), Issue 2 Page 125 DND/MW Lamp Control D-151 D-151 DND/MW Lamp Control General Description This service allows the Message Waiting Lamp to be controlled by setting/cancelling DO NOT DISTURB [D-11] service. The Message Waiting Lamp will either light or flash to distinguish which of the services (MESSAGE WAITING [M-6] or DO NOT DISTURB [D-11]) is being activated. Operating Procedure Refer to the operating procedures of MESSAGE WAITING [M-6] and DO...
Page 140
NEAX2400 IMX Hotel Feature Programming Manual Page 126ND-70284 (E), Issue 2 E-21 Emergency Call Monitor – Attendant E-21 Emergency Call Monitor – Attendant General Description EMERGENCY CALL MONITOR – ATTENDANT alerts the hospitality console operator that a guest has placed a call to an emergency service such as 911. The name and room number of the guest display on the console. Operating Procedure Service Conditions 1. An external bell or buzzer can be connected to the emergency trunk through a relay...