Page 121

NEAX2400 IMX Feature Programming Manual
ND-70184 (E), Issue 3
Page 77
Analog Caller ID - Station A-127
Interactions (cont’d)
Note:
16LCBY and 8RSTY must be used together for Caller ID.
3. Only one route number can be assigned for each sender and register in a PA-8RSTY card.
Programming
ASFC - Assign a Service Feature Class that allows SFI 146 to analog stations allowed this service.
When using Release 7 software or later:
STEP 1:ASFC - Assign the service feature class to each analog station....

Page 122

NEAX2400 IMX Feature Programming Manual
Page 78ND-70184 (E), Issue 3
B-2 Busy Lamp Field - Flexible
B-2  Busy Lamp Field - Flexible
General Description
This feature provides the Attendant with visual indications of either busy, idle or LINE LOCKOUT [L-3] conditions
for a particular group of stations via a designated lamp field on the Attendant Console or the dial pad on the desk
console.
Operating Procedure
1. Press an idle loop key.
2. Key in thousands (where applicable) and hundreds digit(s) of the...

Page 123

NEAX2400 IMX Feature Programming Manual
ND-70184 (E), Issue 3
Page 79
Busy Lamp Field - Flexible B-2
Interactions
1. CENTRALIZED ATTENDANT SERVICE (CAS) [C-20]: At the CAS main location, when the
ATTENDANT CONSOLE [A-3] is handling a call from a CAS branch over a Release Line Trunk (RLT),
the BLF will give no indication of busy/idle status of branch location stations.
2. The BLF indicates the station status after the hundreds digit is keyed in by the Attendant.
3. A 2-digit display indicator is used to...

Page 124

NEAX2400 IMX Feature Programming Manual
Page 80ND-70184 (E), Issue 3
B-3 Busy Verification
B-3 Busy Verification
General Description
When an Attendant places a call to a busy station, this feature allows the Attendant to break into the connection.
When this feature is initiated from the console, the system sends a Warning Tone to the stations before establishing
a three-party conference. Additionally, the Attendant Monitor Function can be activated depending on system data.
Operating Procedure
To...

Page 125

NEAX2400 IMX Feature Programming Manual
ND-70184 (E), Issue 3
Page 81
Busy Verification B-3
Service Conditions (cont’d)
THREE-WAY CALLING  [T-2, T-2D]
VOICE CALL - Dterm[V-2D]
f.) Modem pooling connection
g.) Data Call through Data Adapter
h.) Data Call through Data Module
i.) The calling station is connected to an Attendant Loop
Note:
In each of the above instances, the Attendant will receive reorder tone.
3. Before the Attendant is added to an existing connection, a two-burst tone is applied to alert...

Page 126

NEAX2400 IMX Feature Programming Manual
Page 82ND-70184 (E), Issue 3
B-3 Busy Verification
Service Conditions (cont’d)
15. UNIFORM CALL DISTRIBUTION (UCD) [U-1]: The Attendant can busy-verify a station line that is
part of a UCD group. That is, the BUSY VERIFICATION call will not hunt. If BUSY VERIFICATION
is attempted on the group number, UCD hunting will take precedence over BUSY VERIFICATION.
16. It is determined in system data to allow monitoring of the busy connection before establishing a...

Page 127

NEAX2400 IMX Feature Programming Manual
ND-70184 (E), Issue 3
Page 83
Busy Verification B-3
Interactions (cont’d)
8. CALL WAITING [C-12, 31]: If an Attendant attempts to busy-verify a station line that already has a
Waiting call, BUSY VERIFICATION will be denied. Also, if the Attendant attempts to busy-verify a
station line that is waiting for another line, the BUSY VERIFICATION attempt will be temporarily denied
because such waiting calls always involve either a connection to the Attendant position or...

Page 128

NEAX2400 IMX Feature Programming Manual
Page 84ND-70184 (E), Issue 3
B-5D Boss - Secretary Override - Dterm
B-5D  Boss - Secretary Override - Dterm
General Description
This feature enables a secretary to voice announce a call to a boss when he is currently on his My-Line.
Operating Procedure
 Station 200 - Boss 
 Station 201 - Secretary
Boss is currently connected to Trunk A. Call at Trunk B, intended for 200, reroutes to Station 201. 
1. Secretary answers station 201. 
2. Secretary asks the caller to...

Page 129

NEAX2400 IMX Feature Programming Manual
ND-70184 (E), Issue 3
Page 85
Boss - Secretary Override - DtermB-5D
Service Conditions (cont’d)
6. If provided in the system, the held caller will hear MUSIC ON HOLD [M-7].
7. The call is recorded in SMDR for the secretarys station (e.g., 201).
8. This feature is denied to a UCD [U-1] group.
9. BOSS-SECRETARY OVERRIDE [B-5] overrides DO NOT DISTURB [D-11D] if set for the boss.
10. BOSS-SECRETARY OVERRIDE [B-5] is denied under the following conditions:
ATTENDANT...

Page 130

NEAX2400 IMX Feature Programming Manual
Page 86ND-70184 (E), Issue 3
B-5D Boss - Secretary Override - Dterm
Programming (cont’d)
STEP 5:AKYD - Optional. Assign to a programmable Line/Feature key a CALL HOLD [C-6] key. Assign
Type:Function:CALL HOLD [10]. (The operation of TRANSFER key and access code is also
available.) Optional. Assign to a programmable Line/Feature key a CALL WAITING -
ORIGINATING [C-31] key. Assign Type:Function:CALL WAITING [4]. (The operation of
TRANSFER key and access code is also...