Page 131
NEAX2400 IMX Feature Programming Manual ND-70184 (E), Issue 3 Page 87 Brokerage - Hotline B-6 B-6 Brokerage - Hotline General Description This feature provides a HOT LINE [H-1] function for Dterm. Operating Procedure 1. Lift handset or press the SPEAKER key. 2. Press sub-line key associated with the predetermined desired station. The destination station is automatically dialed; Ringback tone is heard, the destination station answers. 3. After completion of conversation, hang up or press the SPEAKER key....
Page 132
NEAX2400 IMX Feature Programming Manual Page 88ND-70184 (E), Issue 3 B-6 Brokerage - Hotline Service Conditions (cont’d) the destination station is off-hook. the destination station is already engaged in a three-party call. c.) the destination is the Attendant or is connected to an outside party. 16. When EXECUTIVE RIGHT-OF-WAY [E-1, E-1D] is used with this feature, it is not activated under any of the following conditions: when utilizing EXECUTIVE RIGHT-OF-WAY [E-1, E-1D] service using switch hook...
Page 133
NEAX2400 IMX Feature Programming Manual ND-70184 (E), Issue 3 Page 89 Brokerage - Hotline B-6 Programming (cont’d) STEP 3:AKYD - Assign to a D term a line appearance of the Hotline station number. TN: 1 STN: Station Number TP: Type of D term (0/1) KYN: Key Number (1-40) KYI: Service Index 0: Key not used 1: Feature Key 2: Multi-line Key KD: 0 TN, STN:Tenant Number and Station Number of Multi-line (Virtual) RG: Ringing Assignment per Multi-Line Appearance 0: No Ringing 1: Ringing in Day Mode Only 2:...
Page 134
NEAX2400 IMX Feature Programming Manual Page 90ND-70184 (E), Issue 3 B-8 Boss - Secretary - Message Waiting Lamp Control B-8 Boss - Secretary - Message Waiting Lamp Control General Description This feature allows a secretary, via her station, to control the Call Indicator Lamp (Note) or Message Waiting (MW) display on the boss station. Note: The Call Indicator Lamp is used as the MW Lamp. Operating Procedure 1. CALL FORWARDING [C-3, 5] is not set on Boss station. 2. An incoming call for Boss station is...
Page 135
NEAX2400 IMX Feature Programming Manual ND-70184 (E), Issue 3 Page 91 Boss - Secretary - Message Waiting Lamp Control B-8 Service Conditions (cont’d) 6. BOSS-SECRETARY MW LAMP CONTROL indication is cleared by system initialization or a Local Processor initialization. 7. MW control is provided to stations using the D term sub-line when: a.) one station is talking with another station. b.) a special purpose button is pushed after a call is established. c.) the station is calling another station in the...
Page 136
NEAX2400 IMX Feature Programming Manual Page 92ND-70184 (E), Issue 3 B-8 Boss - Secretary - Message Waiting Lamp Control Service Conditions (cont’d) f.) trunk origination or called-number dialing. g.) calls to or talking to Attendant. h.) THREE-WAY CALLING [T-2]. i.) CONSULTATION HOLD - ALL CALLS [C-17]. j.) calls by VOICE CALL - D term [V-2D]. k.) Call Waiting ringback tone with Call Waiting set. l.) secretary calls to boss by BOSS-SECRETARY TRANSFER [B-11]. 13. MW can be cancelled for a station in the...
Page 137
NEAX2400 IMX Feature Programming Manual ND-70184 (E), Issue 3 Page 93 Boss - Secretary - Message Waiting Lamp Control B-8 Programming STEP 1:AKYD - Assign to a programmable line/feature key a MW Lamp Set key; Type:Function:BOSS- SECRETARY MSG WAIT-SET [9] and a MW Lamp Cancel key; Type:Function:BOSS- SECRETARY MSG WAIT-CNCL [11]. STEP 2:ADSL - Assign SN=4 (Communication in Progress) when operating Procedure 1, SN=2 (Originating) when operating Procedure 2. Assign FKY=9 (MW Lamp Set key; MWSET) and FKY=11...
Page 138
NEAX2400 IMX Feature Programming Manual Page 94ND-70184 (E), Issue 3 B-11 Boss - Secretary Transfer B-11 Boss - Secretary Transfer General Description This feature allows a secretary to voice-announce a call to a boss when the secretary answers a call to the boss line. Operating Procedure To transfer from Dterm to Dterm: 1. Call terminates to Boss line. 2. Secretary answers the call on the sub-line of Secretarys D term. 3. Secretary presses the line key of answered call; Boss and Secretary talk by...
Page 139
NEAX2400 IMX Feature Programming Manual ND-70184 (E), Issue 3 Page 95 Boss - Secretary Transfer B-11 Service Conditions (cont’d) 4. This feature must be allowed in CLASS OF SERVICE - INDIVIDUAL [C-15] via System Data programming. 5. BOSS-SECRETARY TRANSFER [B-11] is denied if the secretary is connected to the ATTENDANT CONSOLE [A-3]. 6. If provided in the system, the held caller will hear MUSIC ON HOLD [M-7]. 7. The call is recorded in SMDR [S-10] for the boss station. 8. This feature will override CALL...
Page 140
NEAX2400 IMX Feature Programming Manual Page 96ND-70184 (E), Issue 3 B-12 Brokerage Hotline - Outside B-12 Brokerage Hotline - Outside General Description This feature provides a HOT LINE - OUTSIDE [H-9] function for a Dterm. Operating Procedure To access a BROKERAGE HOT LINE - OUTSIDE from a Dterm: 1. Lift the handset or press the SPEAKER key. 2. Press the sub-line key associated with a predetermined desired outside party. The destination station is automatically dialed; ringback tone is heard; the...