NEAX2400 IMX Feature Programming Manual ND-70184 (E), Issue 3 Page 67 Add On Conference - 8 Party A-121 A-121 Add On Conference - 8 Party General Description This service allows the 8-party conference to be established any time by any conferee by use of the 8-party conference trunk. Operating Procedure To establish an 8-party conference: 1. Station A calls Station B; Station B answers. 2. Station A (or B) switch hook flashes (or press TRANSFER key) and dials Station C’s number; Station C answers. 3....
Page 112
NEAX2400 IMX Feature Programming Manual Page 68ND-70184 (E), Issue 3 A-121 Add On Conference - 8 Party Service Conditions (cont’d) 9. When all of the eight ports of the 8-party conference trunk are filled with the conferees, no other conferee can be added to the conference. 10. The station/trunk which is connected to the 8-party conference trunk can release from the conference at any time. 11. An incoming call from the ringdown trunk, where release cannot be detected, cannot be connected to the 8-party...
Page 113
NEAX2400 IMX Feature Programming Manual ND-70184 (E), Issue 3 Page 69 Add On Conference - 8 Party A-121 Service Conditions (cont’d) 24. The station setting Retain Conference can only cancel Retaining Conference or go on-hook. (No other operation is available.) When the station goes on-hook, the RETAIN CONF lamp turns off. 25. In case of trunk call origination, the billing is performed against the station which originated the trunk call until the trunk releases. Therefore, there may be several billing...
Page 114
NEAX2400 IMX Feature Programming Manual Page 70ND-70184 (E), Issue 3 A-121 Add On Conference - 8 Party Programming (cont’d) STEP 5:ASHP - When the system accommodates multiple PA-CFTB circuit cards, assign a STATION HUNTING - TERMINATING group for the stations programmed to LEN level 0 of each PA-CFTB circuit card. For more details, see the figure below: STEP 6:AKYD - assign FKY 83 to any D terms that require the use of the Retain Conference feature. STEP 7:ADSL - Assign SN=3 (STATION BUSY) and FKY=13...
Page 115
NEAX2400 IMX Feature Programming Manual ND-70184 (E), Issue 3 Page 71 Analog Caller ID (Class SM) A-125 A-125 Analog Caller ID (Class SM) General Description This feature allows the Dterm to display calling party’s number and/or name on the LCD when a call from analog C.O. line is terminated. In addition, the calling number can be output as a part of SMDR information. Caller ID information can be displayed on an analog telephone with a display device or the display of a D term. Operating Procedure No...
Page 116
NEAX2400 IMX Feature Programming Manual Page 72ND-70184 (E), Issue 3 A-125 Analog Caller ID (Class SM) Service Conditions (cont’d) c.) When the received numbers of a calling number and calling name exceed the display field, the decision to put the digits to the right or left may be chosen in system data. An “*” is indicated on the exceeded digit position. d.) The display is flashing during termination. It is lit during conversation. e.) The following are examples of displays when the received digits of a...
Page 117
NEAX2400 IMX Feature Programming Manual ND-70184 (E), Issue 3 Page 73 Analog Caller ID (Class SM) A-125 Programming (cont’d) When Calling Number is output to SMDR, the following expanded format is used: System Data 1, Index 288, Bit 5. Expanded SMDR Output for SMDR A Apparatus. 0/1=Out/In Service. System Data 1, Index 290, Bit 5. Expanded SMDR Output for SMDR B Apparatus. 0/1=Out/In Service. System Data 1, Index 292, Bit 5. Expanded SMDR Output for SMDR C Apparatus. 0/1=Out/In Service. System Data 1,...
Page 118
NEAX2400 IMX Feature Programming Manual Page 74ND-70184 (E), Issue 3 A-125 Analog Caller ID (Class SM) FCCS Programming This data setting describes only the additional or replacement commands used to activate FCCS services. When used as an FCCS feature, these commands replace the non-network commands (for example, AAED is replaced by AAEDN). Note that the data setting for FCCS service varies depending on the node. (Note) STEP 1:ARTDN - Assign route class data for the C.O. trunk. 15-LSG :3 50-DPLY :1...
Page 119
NEAX2400 IMX Feature Programming Manual ND-70184 (E), Issue 3 Page 75 Analog Caller ID - Station A-127 A-127 Analog Caller ID - Station General Description This feature allows a called station to receive CALLER ID information (time, calling number and name) from Central Office when a call terminates via the analog COT. The calling number received from the ISDN network, MF-ANI information received from Central Office with the MF feature or the calling telephone number within the PBX can change into CALLER...
Page 120
NEAX2400 IMX Feature Programming Manual Page 76ND-70184 (E), Issue 3 A-127 Analog Caller ID - Station Service Conditions (cont’d) d.) When the self-address is assigned to the calling ISDN terminal, the self-address is sent. In this case, the sub-address number is not sent. e.) This function is not available even if the analog telephone has the function to restrict sending the calling number on each conversation. f.) The function to restrict the calling number notification is available only when a user...