Page 61
NEAX2400 IMX Feature Programming Manual ND-70184 (E), Issue 3 Page 17 Automatic Recall - DtermA-8D A-8D Automatic Recall - Dterm General Description This feature works as a timed reminder. When a Dterm handled call remains on hold (EXCLUSIVE HOLD [E-4D] or NON-EXCLUSIVE HOLD [N-7D]) or during an unattended transfer for a variable, programmable period of time, the D term is automatically alerted. Operating Procedure No manual operation is required. Service Conditions 1. AUTOMATIC RECALL - Dterm timing is...
Page 62
NEAX2400 IMX Feature Programming Manual Page 18ND-70184 (E), Issue 3 A-15 Announcement Service A-15 Announcement Service General Description This feature allows a user to hear a prearranged announcement when the user dials a predetermined access code. Operating Procedure 1. Lift the handset; receive dial tone. 2. Dial the announcement trunk access code. 3. Listen to the message from the announcement machine. Service Conditions 1. This feature requires one of the following hardware alternatives: a.)...
Page 63
NEAX2400 IMX Feature Programming Manual ND-70184 (E), Issue 3 Page 19 Announcement Service A-15 Programming (cont’d) STEP 3:ARTD - Assign the announcement route as shown below. Be sure to provide privacy by programming CDN 44:PRV as data “1”. RT: 1 1-OSGS :2 2-ONSG :3 5-TF :1 6-TCL :1 7-L/T :1 8-RLP :2 15-LSG :4 STEP 4:ARSC - Assign a Route Restriction Class (RSC) to the station that allows access to the Announcement route. Assign RSC 0 to the Attendant, and allow that RSC access to the Announcement...
Page 64
NEAX2400 IMX Feature Programming Manual Page 20ND-70184 (E), Issue 3 A-15 Announcement Service FCCS Programming This data setting describes only the additional or replacement commands used to activate FCCS services. When used as an FCCS feature, these commands replace the non-network commands (for example, AAED is replaced by AAEDN). Note that the data setting for FCCS service varies depending on the node. STEP 1:ALRTN - This data must be assigned to the NCN. Assign the logical route number to the...
Page 65
NEAX2400 IMX Feature Programming Manual ND-70184 (E), Issue 3 Page 21 Alternate Routing A-16 A-16 Alternate Routing General Description This feature automatically routes outgoing on or off-net calls over alternate facilities when the first-choice trunk group is busy. The user selects the first-choice route by dialing the corresponding access code, and the equipment then routes the call through alternate trunk groups only if the first is busy. The NEAX2400 IMX will also add or delete digits, when...
Page 66
NEAX2400 IMX Feature Programming Manual Page 22ND-70184 (E), Issue 3 A-16 Alternate Routing FCCS Programming Refer to the NEAX2400 IMX Fusion Network System Manual.
Page 67
NEAX2400 IMX Feature Programming Manual ND-70184 (E), Issue 3 Page 23 Audible Indication Control A-17 A-17 Audible Indication Control General Description This feature allows the Attendant to adjust the audible indications provided to the ATTENDANT CONSOLE [A-3]. Operating Procedure The Attendant Console is equipped with a volume control that can raise or lower the internal speaker level. The volume control is located on the left side of the Attendant Console. The audible indication may also be turned...
Page 68
NEAX2400 IMX Feature Programming Manual Page 24ND-70184 (E), Issue 3 A-18 Account Code A-18 Account Code General Description This feature is an adjunct to STATION MESSAGE DETAIL RECORDING [S-10], which provides a user with the capability to enter a cost-accounting or client-billing code (up to 10 digits) into the system before dialing a long distance number. Operating Procedure To enter an ACCOUNT CODE: 1. Lift the handset; receive dial tone. 2. Dial the feature access code; receive service set tone. 3....
Page 69
NEAX2400 IMX Feature Programming Manual ND-70184 (E), Issue 3 Page 25 Account Code A-18 Interactions (cont’d) 5. The access code for ACCOUNT CODES is restricted to a maximum of three digits. 6. STATION MESSAGE DETAIL RECORDING [S-10] Split Billing (System Data Option): On transferred calls, or incoming calls via the Attendant Console, the ACCOUNT CODE will be recorded in all the call records. 7. When OUTGOING TRUNK QUEUING [O-2] is initiated, the ACCOUNT CODE will be recorded when the call is completed....
Page 70
NEAX2400 IMX Feature Programming Manual Page 26ND-70184 (E), Issue 3 A-18 Account Code FCCS Programming This data setting describes only the additional or replacement commands used to activate FCCS services. When used as an FCCS feature, these commands replace the non-network commands (for example, AAED is replaced by AAEDN). Note that the data setting for FCCS service varies depending on the node. (Note) STEP 1:ANPDL - Reserve a number level for service feature access. Assign Connection Index, CI = N,...