Page 71

NEAX2400 IMX Feature Programming Manual
ND-70184 (E), Issue 3
Page 27
Attendant Night Transfer A-19
A-19 Attendant Night Transfer
General Description
When the ATTENDANT CONSOLE [A-3] is in night mode, any operator calls (dial 0 calls) are automatically
routed to a predetermined night station.
Operating Procedure
To answer night call:
1. The user dials the operator call code; receives ringback tone.
2. An operator call is automatically transferred to the night answer station.
3. The calling party hears...

Page 72

NEAX2400 IMX Feature Programming Manual
Page 28ND-70184 (E), Issue 3
A-19 Attendant Night Transfer
Service Conditions (cont’d)
13. Operator calls after Consultation Hold is not transferred to the Night Station.
14. Individual Attendant calls are not transferred to the Night Station assigned by ATTENDANT NIGHT
TRANSFER.
15. The Night Station can set CALL FORWARDING - ALL CALLS - OUTSIDE [C-28], CALL
FORWARDING - BUSY LINE - OUTSIDE [C-60], and CALL FORWARDING - DONT ANSWER -
OUTSIDE [C-74].
16. When a DIT...

Page 73

NEAX2400 IMX Feature Programming Manual
ND-70184 (E), Issue 3
Page 29
Authorization Code A-20
A-20 Authorization Code
General Description
An AUTHORIZATION CODE is a numerical code dialed by users (up to 10 digits), which will override the station
CLASS OF SERVICE - INDIVIDUAL [C-15] for facility access restriction. 
The AUTHORIZATION CODE can be masked on the D
term display if necessary using the AUTHORIZATION
CODE DISPLAY ELIMINATION [A-99].
When a wrong code is received from a station/trunk, detailed...

Page 74

NEAX2400 IMX Feature Programming Manual
Page 30ND-70184 (E), Issue 3
A-20 Authorization Code
Service Conditions
1. A maximum of 10 digits for AUTHORIZATION CODE can be dialed, and 8 digits will be registered on
STATION MESSAGE DETAIL RECORDING [S-10].
2. The maximum number of AUTHORIZATION CODES is 4,000. This number is dependent upon system
configuration.
These specifications are based on the digits being assigned as follows:
1st digit: A (when A equals a unique digit from 0 - 9)
2nd digit:  B - C (when...

Page 75

NEAX2400 IMX Feature Programming Manual
ND-70184 (E), Issue 3
Page 31
Authorization Code A-20
Interactions (cont’d)
5. There are no restrictions regarding the first digit of AUTHORIZATION CODES, except what is
programmed in AMND. Tenant 0 does not conflict with the PBX numbering plan. This is true when
separate tenant tables are provided. If common tenant tables are used, a conflict between LCR(S) and
OGC(A), used with SMDR, will occur.
Note:
The access code to the service feature AUTHORIZATION CODE must...

Page 76

NEAX2400 IMX Feature Programming Manual
Page 32ND-70184 (E), Issue 3
A-20 Authorization Code
Programming (cont’d)
System Data 1, Index 13. Each Bit in Index 13 directly correlates to a digit in the AUTHORIZATION
CODE assigned in AATC, and will determine the second digit of the Checksum method. Pick any Bits
0 - 4, but not the same combination of Bits as picked in Index 12.
System Data 1, Index 14 determines the algorithm used to calculate the last two digits of every
AUTHORIZATION CODE. (Only decimal...

Page 77

NEAX2400 IMX Feature Programming Manual
ND-70184 (E), Issue 3
Page 33
Authorization Code A-20
Programming (cont’d)
STEP 2:ANPD - Reserve a number level for feature access. Assign for Normal (N), Hooking (H), and Busy
(B) (if applicable to any feature in this level). Assign NND in accordance with a predetermined
numbering plan.
STEP 3:ASPA - For SRV = SSC (Service Code), SID = 42, assign the access code. For the NND parameter, no
assignment is required when AUTHORIZATION CODE operates by itself. When...

Page 78

NEAX2400 IMX Feature Programming Manual
Page 34ND-70184 (E), Issue 3
A-20 Authorization Code
FCCS Programming (cont’d)
STEP 3:LATCL - List up all the AUTHORIZATION CODES. This is the simplest way to determine what
digits have been added to the system with the Checksum method. This is not required if the Checksum
method is not used.
Note:
When using ASYDL or ASYDN to program an FCCS feature, the basic programming of ASYD is required in addition
to ASYDL or ASYDN. 

Page 79

NEAX2400 IMX Feature Programming Manual
ND-70184 (E), Issue 3
Page 35
Automatic Trunk Test A-21
A-21  Automatic Trunk Test
General Description
The AUTOMATIC TRUNK TEST capability provides a functional test on a large number of trunks at a prearranged
time. The results of the test are reported at the MAINTENANCE ADMINISTRATION TERMINAL (MAT) [M-
18]. The test can include: Ringback Tone Test, 1 KHz Test Tone and Trunk Selection Test, by having the proper test
trunk termination at the distant office....

Page 80

NEAX2400 IMX Feature Programming Manual
Page 36ND-70184 (E), Issue 3
A-21 Automatic Trunk Test
Programming
STEP 1:ANPD - Reserve a number level for service feature access. Assign for Normal (N), Assign NND in
accordance with a predetermined numbering plan.
STEP 2:ASPA - The access code for INDIVIDUAL TRUNK ACCESS must be assigned, SID = 17. Assign
Connection Index, CI = (N) Normal. NND is assigned in accordance with a predetermined numbering
plan.
STEP 3:ARSC - A Route Restriction Class (RSC) must be...