Page 121
NEAX2000 IVS2 ISDN System ManualPage 110 ND-70919 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING ISDN Terminal Data Programming (4) Station to Station Calling When an ISDN Terminal user dials an ISDN Terminal station number within the system, the system connects the call with the specified ISDN Terminal. Do the programming of Point-to-Multipoint Connection. See Page 105. ISDN ISDN Terminal Station No. 407ISDN Terminal Station No. 400ISDN Line Station No. 300 ILC TRKPBX ISDN Terminal Station No....
Page 122
CHAPTER 3 SYSTEM DATA PROGRAMMING ISDN Terminal Data Programming NEAX2000 IVS2 ISDN System Manual ND-70919 (E), Issue 1.0 Page 111 Group Call (1) ISDN Indial When receiving an ISDN line station number as ISDN Indial number, or when converting an ISDN Indial number to an ISDN line station number by CM76, the system connects the call with all ISDN Terminals or Terminal Adapters (TA) on the same bus (2B + D). Do the following programming: DID Addressing (See Page 83.) Point-to-Multipoint Connection...
Page 123
NEAX2000 IVS2 ISDN System ManualPage 112 ND-70919 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING ISDN Terminal Data Programming (2) Called Par ty Subaddress When receiving an ISDN line station number as the Called Party Subaddress, the system connects the call with all ISDN Terminals or Terminal Adapters (TA) on the same bus (2B + D). Do the following programming: Subaddress-Present (See Page 89.) Point-to-Multipoint Connection (See Page 105.) ISDN ISDN Terminal Station No. 407ISDN Terminal...
Page 124
CHAPTER 3 SYSTEM DATA PROGRAMMING ISDN Terminal Data Programming NEAX2000 IVS2 ISDN System Manual ND-70919 (E), Issue 1.0 Page 113 (3) Direct In Termination (DIT) When the ISDN line station number is assigned as the destination of DIT, the call from ISDN terminates all ISDN Terminals on the same bus (2B + D) simultaneously. In addition to the programming of Point-to-Multipoint Connection on Page 105, do the following programming: DESCRIPTION DATA Assign the data for DIT to the trunk num- bers...
Page 125
NEAX2000 IVS2 ISDN System ManualPage 114 ND-70919 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING ISDN Terminal Data Programming (4) Station to Station Calling When an ISDN Terminal user dials an ISDN line station number within the system, the system connects the call with all ISDN Terminals. Do the programming of Point-to-Multipoint Connection. See Page 105. ISDN ISDN Terminal Station No. 407ISDN Terminal Station No. 400ISDN Line Station No. 300 ILC TRKPBX ISDN Terminal Station No. 417ISDN Terminal...
Page 126
CHAPTER 3 SYSTEM DATA PROGRAMMING Event Based CCIS Programming NEAX2000 IVS2 ISDN System Manual ND-70919 (E), Issue 1.0 Page 115 EVENT BASED CCIS PROGRAMMING Programming Summary Do the system data programming for Event Based CCIS according to the procedure shown in Figure 3-2. As for the CCIS feature programming, refer to the CCIS System Manual. Figure 3-1 shows an outline of BRI to BRI connections. Figure 3-1 Outline of BRI to BRI Connections Programming for PBX A and PBX B is required on each...
Page 127
NEAX2000 IVS2 ISDN System ManualPage 116 ND-70919 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING Event Based CCIS Programming Figure 3-2 Event Based CCIS Programming Summary START BRI Trunk Programming for E-CCIS Home Side TrunkSee Page 117. See Page 118. See Page 122. Programming Numbering Plan Programming BRI or PRI? Refer to ISDN-PRI Programming on Page 65.PRI BRI Mate Side Trunk See Page 124. Programming Incoming Termination See Page 131. Programming Access Code/Terminating See Page 132. No....
Page 128
CHAPTER 3 SYSTEM DATA PROGRAMMING Event Based CCIS Programming NEAX2000 IVS2 ISDN System Manual ND-70919 (E), Issue 1.0 Page 117 Numbering Plan Programming DESCRIPTION DATA Assign station number, LCR and trunk route access codes. (1) (2)Y=0-3 X-XXXX: Access Code 801-808 : 1 to 8 digits station A126-A129: LCR Group 0-3 100-163 : Trunk Route 00-63START CM20 END
Page 129
NEAX2000 IVS2 ISDN System ManualPage 118 ND-70919 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING Event Based CCIS Programming BRI Trunk Programming DESCRIPTION DATA Assign an AP number to the BRT card. The AP number must match the SENS switch setting on the BRT card. (1) (2)Y=0 04-15, 20-31: AP No. 10: BRT card Assign the ISDN Protocol Type for DCH circuit on the BRT card. (1) (2)YY=06 04-15, 20-31: AP No. of BRT assigned by CM05 ISDN Protocol Type 17 : Australia 18 : New Zealand 20 : AT&T...
Page 130
CHAPTER 3 SYSTEM DATA PROGRAMMING Event Based CCIS Programming NEAX2000 IVS2 ISDN System Manual ND-70919 (E), Issue 1.0 Page 119 DESCRIPTION DATA Assign the trunk route data to each ISDN incoming trunk used for Voice channel only. (1) (2)YY=02 Day Mode YY=03 Night Mode YY=40 Mode A YY=41 Mode B 000-255: Trunk No. assigned by CM07 Y=01 18: ISDN Indial Assign an ISDN subscriber number (last 4 digits of telephone number) to each ISDN trunk. (1) (2)YY=19 000-255: Trunk No. assigned by...