Page 111
NEAX2000 IVS2 ISDN System ManualPage 100 ND-70919 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING ISDN-VPN Programming DESCRIPTION DATA (1) (2)YYYY=9000-9025: Digit Addition Pat- tern No. 00-255 0 X-X...X: Digits to be added (Max. 32 digits) To delete the designated digit of an area code assigned by YYYY=4000-4007. (1) (2)YYYY=5000-5255 153: Designation of digit to be deleted from area code assigned by YYYY=4000-4007 00 : No digit deletion 01-10: Leading 1-10 digits deletion CCC : No digit...
Page 112
CHAPTER 3 SYSTEM DATA PROGRAMMING ISDN Terminal Data Programming NEAX2000 IVS2 ISDN System Manual ND-70919 (E), Issue 1.0 Page 101 ISDN TERMINAL DATA PROGRAMMING ILC Assignment DESCRIPTION DATA Assign an ISDN line station number to the required LEN.(1) (2)000-763: LEN EFX-EFXXXXXXXX: ISDN Line Station No. Assign a Tenant number to each ISDN line station number. (1) (2)YY=04 X-XXXXXXXX: ISDN Line Station No. 00-63: Tenant No. If no data is set, the default data is 01. Assign a Trunk...
Page 113
NEAX2000 IVS2 ISDN System ManualPage 102 ND-70919 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING ISDN Terminal Data Programming DESCRIPTION DATA Specify the facility control of CPN (Calling Par ty Number). (1) (2)YY=25 X-XXXXXXXX: ISDN Line Station No. 0 : Provided 1 : Not provided Assign the digit number of ISDN line station number. (1) (2)Y=0-3 X-XXXX: Access Code 801-808: 1 digit-8 digits Specify whether the subaddress is sent to ISDN when making a call from ISDN Terminal, if required.(1)...
Page 114
CHAPTER 3 SYSTEM DATA PROGRAMMING ISDN Terminal Data Programming NEAX2000 IVS2 ISDN System Manual ND-70919 (E), Issue 1.0 Page 103 ICH Assignment DESCRIPTION DATA Assign an AP number to each ICH card (PN-SC03). The AP number must match the SENS switch setting on the ICH card. (1) (2)Y=0 04-15: AP No. 13: ICH card Assign the ICH number to the AP number of ICH assigned by CM05. (1) (2)YY=09 00-15: ICH No. 04-15: AP No. assigned by CM05 Assign the ISDN line station number to the ISDN line...
Page 115
NEAX2000 IVS2 ISDN System ManualPage 104 ND-70919 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING ISDN Terminal Data Programming Point-to-Point Connection DESCRIPTION DATA Assign the point to point connection as the Layer 2 data link. (1) (2)YY=01 XX Z XX: 00-15: ICH No. Z : 0-7: ISDN Line No. of ICH card 0: Point to Point Connection NOTE:When Point-to-Point Connection is selected, the PBX will address the BRI Terminal with channel select (B1/B2) message. Some BRI Terminals cannot answer the call...
Page 116
CHAPTER 3 SYSTEM DATA PROGRAMMING ISDN Terminal Data Programming NEAX2000 IVS2 ISDN System Manual ND-70919 (E), Issue 1.0 Page 105 Point-to-Multipoint Connection DESCRIPTION DATA Assign the point to multipoint connection as the Layer 2 data link. (1) (2)YY=01 XX Z XX: 00-15: ICH No. Z : 0-7: ISDN Line No. of ICH card 1 : Point-to-Multipoint Connection Specify the passive bus. (1) (2)YY=03 XX Z XX: 00-15: ICH No. Z : 0-7: ISDN Line No. of ICH card 0 : Extended Passive Bus 1 : Short Passive...
Page 117
NEAX2000 IVS2 ISDN System ManualPage 106 ND-70919 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING ISDN Terminal Data Programming BRI Programming Example: The following is an example of common BRI Station Programming. CM10024>EF2125 025>EF2126 CM AC00>000-2125 001-2126 CM CM CM CM CMAC01>000-1 001-1 AC02>000-1 001-1 AC03>000-1 001-1 AC04>000-1 001-1 AC06>000-1 001-1CM1B>2125, 0>2225* 2125, 1>2226 2 >None 7 2126, 0>2235* 2126, 1>2236* 2 >None 7 * Ext. 2225 and others assigned in CM1B are the Extension...
Page 118
CHAPTER 3 SYSTEM DATA PROGRAMMING ISDN Terminal Data Programming NEAX2000 IVS2 ISDN System Manual ND-70919 (E), Issue 1.0 Page 107 Individual Terminal Call (1) ISDN Indial When receiving an ISDN Terminal station number as the ISDN Indial number, or when converting an ISDN Indial number to an ISDN Terminal station number, by CM76, the system connects the call with the specified ISDN Terminal or Terminal Adapter (TA) on the same bus (2B + D). Do the following programming: DID Addressing (See Page...
Page 119
NEAX2000 IVS2 ISDN System ManualPage 108 ND-70919 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING ISDN Terminal Data Programming (2) Called Par ty Subaddress When the system has received a Called Party Subaddress (ISDN Terminal station number) from an ISDN Subscriber, the system connects the call with the specified ISDN Terminal or TA on the same bus (2B + D). Do the following programming: Subaddress-Present (See Page 89.) Point-to-Multipoint Connection (See Page 105.) ISDN ISDN Terminal Station...
Page 120
CHAPTER 3 SYSTEM DATA PROGRAMMING ISDN Terminal Data Programming NEAX2000 IVS2 ISDN System Manual ND-70919 (E), Issue 1.0 Page 109 (3) Direct In Termination (DIT) When the ISDN Terminal station number is assigned as the destination of DIT, the system connects the call with the specified ISDN Terminal or TA on the same bus (2B + D). In addition to the programming of Point-to-Multipoint Connection on Page 105, do the following programming: DESCRIPTION DATA Assign the data for DIT to the trunk...