Page 151
NEAX2000 IVS2 ISDN System ManualPage 140 ND-70919 (E), Issue 1.0 CHAPTER 4 CIRCUIT CARD INFORMATION List of Required Circuit Cards LIST OF REQUIRED CIRCUIT CARDS Table 4-1 shows the required circuit cards that are explained in this section. * MB = Make Busy Table 4-1 List of Required Circuit Card NAME (FUNCTIONAL NAME) LAMP X: PROVIDED –: NOT PROVIDEDSWITCH X: PROVIDED –: NOT PROVIDEDEXTRACTION/ INSERTION WITH POWER ON X: ALLOWED : ALLOWED AFTER MB* –: NOT ALLOWEDREFERENCE PAGE PN-CP14 (MP) X X...
Page 152
CHAPTER 4 CIRCUIT CARD INFORMATION PN-CP14 (MP) NEAX2000 IVS2 ISDN System Manual ND-70919 (E), Issue 1.0 Page 141 PN-CP14 (MP) Locations of Lamps, Switches, and Connectors Lamp Indications LAMP NAMECOLOR FUNCTION RUN Green Flashes at 120 IPM while this card is operating normally CLK Green Remains lit while receiving clock signals to the PLO SW3 RUN SW1 SW2 CLK VR DK JACK CONNSW4 JP0JP1 RS1 RS0 CONN: To CONNR connector on PZ-M537 (EXPMEM)
Page 153
NEAX2000 IVS2 ISDN System ManualPage 142 ND-70919 (E), Issue 1.0 CHAPTER 4 CIRCUIT CARD INFORMATION PN-CP14 (MP) Switch Settings NOTE 1:Set the groove on the switch to the desired position. NOTE 2:Only when executing MP Program Download using the Software Activation Tool in MATWorX Studio, set the SW3 to 5-8. CAUTION When the operating power is being supplied to this circuit card, do not plug/unplug this circuit card into/from its mounting slot. SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION...
Page 154
CHAPTER 4 CIRCUIT CARD INFORMATION PN-CP14 (MP) NEAX2000 IVS2 ISDN System Manual ND-70919 (E), Issue 1.0 Page 143 SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SW1 (Push SW)For initializing CPU SW2 (Piano Key SW)1ON A-law (Australia) OFF µ-law (North America) 2, 3Selection of PLO0 input (Phase Locked Oscillator) For clock receiver office: For clock source office: SW2-2 SW2-3 OFF OFF 4ONWhen using RS1 port for built-in MODEM OFF When using RS1 port for RS-232C (Continued) 4 3 2 1...
Page 155
NEAX2000 IVS2 ISDN System ManualPage 144 ND-70919 (E), Issue 1.0 CHAPTER 4 CIRCUIT CARD INFORMATION PN-CP14 (MP) SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SW4 (DIP SW)1 Not used 2 Not used 3, 4Selection of PLO1 input (Phase Locked Oscillator) For clock receiver office: For clock source office: SW4-3 SW4-4 OFF OFF VR (Rotary SW) Variable Resistor for External Hold Tone Source (0-20 Kohms: Clockwise) DK (Connector) 02 Ground detection 01 Ground sending (Continued) 1 23 4ON OFF OFF...
Page 156
CHAPTER 4 CIRCUIT CARD INFORMATION PN-CP14 (MP) NEAX2000 IVS2 ISDN System Manual ND-70919 (E), Issue 1.0 Page 145 The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK JP0 (Jumper Pin)UPNot used (Memory backup OFF) For normal operation (Memory...
Page 157
NEAX2000 IVS2 ISDN System ManualPage 146 ND-70919 (E), Issue 1.0 CHAPTER 4 CIRCUIT CARD INFORMATION PN-BRTA (BRT) PN-BRTA (BRT) Locations of Lamps, Switches, and Connectors SENSE RUN MB SW1 SW0B1 B2 D ALM
Page 158
CHAPTER 4 CIRCUIT CARD INFORMATION PN-BRTA (BRT) NEAX2000 IVS2 ISDN System Manual ND-70919 (E), Issue 1.0 Page 147 Lamp Indications LAMP NAMECOLOR FUNCTION RUN Green Flashes at 120 IPM while this card is operating normally B1 Green B1 channel status ON: Busy OFF: Idle Flash (60 IPM): Make Busy B2 Green B2 channel status ON: Busy OFF: Idle Flash (60 IPM): Make Busy D Green D channel status ON: Busy OFF: Idle ALM Red Transmission line fault status ON: Line fault OFF: Normal operation
Page 159
NEAX2000 IVS2 ISDN System ManualPage 148 ND-70919 (E), Issue 1.0 CHAPTER 4 CIRCUIT CARD INFORMATION PN-BRTA (BRT) Switch Settings SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SENS (Rotary SW) NOTE 14-F Set the switch to match the AP Number (04-15) to be set by CM05. 0-3 Not used MB (Toggle SW) NOTE 2 UP For make-busy For normal operation SW0 (DIP SW) 1For normal operation OFF Not used 2 NOTE 3 NOTE 4ONSource clock signal from network is sent to the PLO of MP according to the switch...
Page 160
CHAPTER 4 CIRCUIT CARD INFORMATION PN-BRTA (BRT) NEAX2000 IVS2 ISDN System Manual ND-70919 (E), Issue 1.0 Page 149 The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. NOTE 1:Set the groove on the switch to the desired position. NOTE 2:When the power is on, flip the MB switch to ON (UP position) before...