 NEAX2000 IVS2 ISDN System ManualPage 170  ND-70919 (E), Issue 1.0
CHAPTER 4  CIRCUIT CARD INFORMATION
PN-24PRTA (PRT)
MB (Toggle SW)
NOTE 2UP For make-busy
For normal operation
SW0
(Piano Key SW)
1
NOTE 3
NOTE 4ONSource clock signal from network is 
sent to the PLO0 input on MP card.
OFFSource clock signal from network is 
not sent to the PLO0 input on MP 
card. 
2 
NOTE 3
NOTE 4ONSource clock signal from network is 
sent to the PLO1 input on MP card.
OFFSource clock signal from network is 
not sent to...

Page 182

CHAPTER 4  CIRCUIT CARD INFORMATION
PN-24PRTA (PRT)
NEAX2000 IVS2 ISDN System Manual    
ND-70919 (E), Issue 1.0   Page 171
SWITCH NAMESWITCH 
NUMBERSETTING 
POSITIONFUNCTION CHECK
SW1
(Piano Key SW)
NOTE 41 Not used
2 Not used
3 Not used
4ON AP No. 04-15
OFF AP No. 20-31
SW2 (DIP SW) 1
Always set to OFF.
2[Nor th America only for AT&T]
ONDeletion of Area Code on 
International Outgoing call
OFFNo deletion of Area Code on 
International Outgoing call
[Australia/Other countries]
Always set to OFF.
3...

Page 183

 NEAX2000 IVS2 ISDN System ManualPage 172  ND-70919 (E), Issue 1.0
CHAPTER 4  CIRCUIT CARD INFORMATION
PN-24PRTA (PRT)
The figure in the SWITCH NAME column and the position in    in the SETTING POSITION
column indicate the standard setting of the switch. When the switch is not set as shown by the
figure and   , the setting of the switch varies with the system concerned.
NOTE 1:Set the groove on the switch to the desired position.
NOTE 2:When the power is on, flip the MB switch to ON (UP position) before...

Page 184

CHAPTER 4  CIRCUIT CARD INFORMATION
PN-24PRTA (PRT)
NEAX2000 IVS2 ISDN System Manual    
ND-70919 (E), Issue 1.0   Page 173
NOTE 3:Set SW0-1 and SW0-2 as follows:
NOTE 4:When the PBX is a clock source office, set the SW0-1 and SW0-2 on all the PRT cards
mounted in PIM0 to OFF.
NOTE 5:Mount the PRT card which receives a source clock signal into PIM 0.
CONDITIONSPRT0 PRT1 PRT2 PRT3 PRT4
REMARKS
SW
0-1SW
0-2SW
0-1SW
0-2SW
0-1SW
0-2SW
0-1SW
0-2SW
0-1SW
0-2
When one PRT 
is provided.ONOFF––––––––MP card will...

Page 185

 NEAX2000 IVS2 ISDN System ManualPage 174  ND-70919 (E), Issue 1.0
CHAPTER 4  CIRCUIT CARD INFORMATION
PN-SC00 (CCH)
PN-SC00 (CCH)
Locations of Lamps, Switches and Connectors
Lamp Indications
LAMP 
NAMECOLOR FUNCTION
RUN Green Flashes at 120 IPM while this card is operating normally
LC Green Remains lit when communications are normally ongoing with the 
common signalling channel data links connected
LPB Green Remains lit when a loop-back test is in progress
RS
SENSE
RUN
MB
SW0
LC
LPB SW1
TO  M O D E M...

Page 186

CHAPTER 4  CIRCUIT CARD INFORMATION
PN-SC00 (CCH)
NEAX2000 IVS2 ISDN System Manual    
ND-70919 (E), Issue 1.0   Page 175
Switch Settings
SWITCH
NAMESWITCH
NUMBERSETTING
POSITIONFUNCTION CHECK
SENS
(Rotary SW)
NOTE 14-F Set the switch to match the AP Number (04-31) to
be set by CM05.
0-3 Not used
MB (Toggle SW)
NOTE 2
UP For make-busy
For normal operation
SW0
(Piano Key SW)1ON Loop-back test
For normal operation
2ON Analog interface
OFF Digital interface
3ONRS-232C RTS signal (to MODEM) 
ON  NOTE 3...

Page 187

 NEAX2000 IVS2 ISDN System ManualPage 176  ND-70919 (E), Issue 1.0
CHAPTER 4  CIRCUIT CARD INFORMATION
PN-SC00 (CCH)
The figure in the SWITCH NAME column and the position in   in the SETTING POSITION
column indicate the standard setting of the switch. When the switch is not set as shown by the
figure and   , the setting of the switch varies with the system concerned.
NOTE 1:Set the groove on the switch to the desired position.
NOTE 2:When the power is on, flip the MB switch to ON (UP position) before...

Page 188

CHAPTER 4  CIRCUIT CARD INFORMATION
PN-SC01 (DCH)
NEAX2000 IVS2 ISDN System Manual    
ND-70919 (E), Issue 1.0   Page 177
PN-SC01 (DCH)
Locations of Lamps, Switches, and Connectors
Lamp Indications
LAMP 
NAMECOLOR FUNCTION
RUN Green Flashes at 120 IPM while this card is operating normally
LC Green Remains lit when communications are normally ongoing with the 
D channel data links connected
LPB Green Not used
SENSE
RUN
MB
SW0
LC 
LPB SW1 

Page 189

 NEAX2000 IVS2 ISDN System ManualPage 178  ND-70919 (E), Issue 1.0
CHAPTER 4  CIRCUIT CARD INFORMATION
PN-SC01 (DCH)
Switch Settings
SWITCH
NAMESWITCH
NUMBERSETTING
POSITIONFUNCTION CHECK
SENS
(Rotary SW)
NOTE 14-F Set the switch to match the AP Number (04-31) to
be set by CM05.
0-3 Not used
MB (Toggle SW)
NOTE 2
UP For make-busy
For normal operation
SW0
(Piano Key SW)1 Always set to OFF.
2 Always set to OFF.
3 Always set to OFF.
4ON AP No. 04-15
OFF AP No. 20-31
(Continued)
F
4
AP No.SW0-4: ON
04 05 06...

Page 190

CHAPTER 4  CIRCUIT CARD INFORMATION
PN-SC01 (DCH)
NEAX2000 IVS2 ISDN System Manual    
ND-70919 (E), Issue 1.0   Page 179
The figure in the SWITCH NAME column and the position in   in the SETTING POSITION
column indicate the standard setting of the switch. When the switch is not set as shown by the
figure and   , the setting of the switch varies with the system concerned.
NOTE 1:Set the groove on the switch to the desired position.
NOTE 2:When the power is on, flip the MB switch to ON (UP position)...