NEAX2000 IVS2 ISDN System ManualPage 80 ND-70919 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING ISDN-BRI Programming When providing Tandem Connection (COT/ODT/LDT/DTI to ISDN, ISDN to COT/ODT/LDT/ DTI), do the following programming: DESCRIPTION DATA Specify whether the busy tone is sent to a calling party of ISDN when a called party is busy in the tandem connection (ISDN to COT).(1) (2)407 0 : Available (BT) 1 : Not available (RBT) Specify the combination of trunk routes allowing the tandem...
Page 92
CHAPTER 3 SYSTEM DATA PROGRAMMING ISDN-BRI Programming NEAX2000 IVS2 ISDN System Manual ND-70919 (E), Issue 1.0 Page 81 When providing Tandem Connection (ISDN to CCIS, CCIS to ISDN), do the following programming: Specify whether the Calling Party Number (CPN) sent from ISDN is sent to the CCIS network. DESCRIPTION DATA Specify the combination of trunk routes allowing the tandem connection. (1) (2)Y=0 XX ZZ XX: 00-63: Incoming Trunk Route ZZ : 00-63: Outgoing Trunk Route 0 : Allowed 1:...
Page 93
NEAX2000 IVS2 ISDN System ManualPage 82 ND-70919 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING ISDN Feature Programming ISDN FEATURE PROGRAMMING Calling Party Recognition Service (Direct-In Termination (DIT)) Refer to “Direct Inward Termination (DIT)” in the Feature Programming Manual. DID Addressing (See Page 83.) MEGACOM ® Access [North America Only] (See Page 85.) MEGACOM ® 800 Service [North America Only] Refer to “DID Addressing” for programming instructions. (See Page 83.) SID...
Page 94
CHAPTER 3 SYSTEM DATA PROGRAMMING ISDN Feature Programming NEAX2000 IVS2 ISDN System Manual ND-70919 (E), Issue 1.0 Page 83 DID Addressing DESCRIPTION DATA Assign the data for DID to the trunk numbers assigned by CM07. (1) (2)YY=02 Day Mode YY=03 Night Mode YY=40 Mode A YY=41 Mode B 000-255: Trunk No. assigned by CM07 YY=01 18: ISDN Indial Assign the data for DID to the trunk routes assigned by CM30. (1) (2)YY=00 Kind of Trunk 00-63: Trunk Route No. 00: DID (1) (2)YY=02 OG/IC 00-63:...
Page 95
NEAX2000 IVS2 ISDN System ManualPage 84 ND-70919 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING ISDN Feature Programming DESCRIPTION DATA (1) (2)YY=18 Received Digit Conversion 00-63: Trunk Route No. 0 : Provided 1 : Not provided Assign the destination of DID Call transferred when the station is busy/ unassigned/no answer. (1) (2)YY=00 No Answer YY=03 Busy YY=06 Unassigned 00-63: Tenant No. Destination: X-XXXXXXXX: Station No. E000 : Attendant Console EBXXX: Announcement Service: Digital...
Page 96
CHAPTER 3 SYSTEM DATA PROGRAMMING ISDN Feature Programming NEAX2000 IVS2 ISDN System Manual ND-70919 (E), Issue 1.0 Page 85 MEGACOM® Access [North America Only] In addition to the programming of Direct Outward Dialing, assign WATS line to the required trunk route, as shown below: DESCRIPTION DATA Assign the Trunk Restriction Class to each station. (1) (2)YY=01 Trunk Restriction Class X-XXXXXXXX: Station No. XZ X: 1 -8: Trunk Restriction Class in Day mode Z: 1 -8: Trunk Restriction Class in...
Page 97
NEAX2000 IVS2 ISDN System ManualPage 86 ND-70919 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING ISDN Feature Programming SID to Network-Present/ CPN to Network-Present For providing the Calling Party Number (CPN) to the network, do the following programming: When Dial-In service is provided: When ISDN (BRI) Terminals are used: DESCRIPTION DATA Assign an ISDN Subscriber number and ISDN Local Office Code Table number to required stations. NOTE 1 (1) (2)YY=12 X-XXXXXXXX: Station No. X-XXXX:...
Page 98
CHAPTER 3 SYSTEM DATA PROGRAMMING ISDN Feature Programming NEAX2000 IVS2 ISDN System Manual ND-70919 (E), Issue 1.0 Page 87 NOTE 1:The ISDN number consists of the following numbers: ISDN number: XXXXXXXXXXXX YYYY ISDN subscriber No. assigned by CM12 YY=12 (1-4 digits) ISDN Local Office Code assigned by CM50 YY=05 (1-12 digits) This number must be in the indial range assigned by Telecom for the ISDN line. For example: National Destination Code for Dallas: 214 Local Code for a station: 518-5000 In...
Page 99
NEAX2000 IVS2 ISDN System ManualPage 88 ND-70919 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING ISDN Feature Programming When Dial-In service is not provided: DESCRIPTION DATA Specify the sending out of CPN (Calling Par ty Number). (1) (2)YY=25 X-XXXXXXXX: Station No. 0 : Sent 1 : Not sent Assign an ISDN subscriber number to each ISDN trunk. NOTE 1 on previous page (1) (2)YY=19 000-255: Trunk No. assigned by CM07 YY=01 XXXX: ISDN Subscriber No. Assign ISDN Local Office Code Table number to...
Page 100
CHAPTER 3 SYSTEM DATA PROGRAMMING ISDN Feature Programming NEAX2000 IVS2 ISDN System Manual ND-70919 (E), Issue 1.0 Page 89 Subaddress-Present (1) Calling Party Subaddress When a station has dialed an ISDN subscriber number, the station number is automatically sent as a Calling Party Subaddress. (2) Called Par ty Subaddress When the system has received a Called Par ty Subaddress (Calling Station Number) from an ISDN subscriber, the system connects the call with the specified terminal....