Page 281
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-DAIA (DAI) NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 255 The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. NOTE 1: Set the groove on the switch to the desired position. NOTE 2: When the power is on, flip the MB switch to ON (UP...
Page 282
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-DAIA (DAI) NEAX2000 IVS2 Installation Procedure ManualPage 256ND-70928 (E), Issue 1.0 NOTE 3: When clock source office signal is supplied via the line between the main site and the remote site, set the SW1-1 and SW1-2 as the following table. In this case, DAIA cards (DAIA0, DAIA1) must be mounted in PIM0. NOTE 4: The time slot number 0, 20, 21, and 22 (TS0/20/21/22) cannot be used for control sig- nal. NOTE 5: This setting must be identical with the...
Page 283
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-DAIB (DAI) NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 257 PN-DAIB (DAI) Location of Lamps, Switches, and Connectors Lamp Indications LAMP NAMECOLOR FUNCTION RUN Green Flashes at 120 IPM while this card is operating normally. LINK Green Remains lit when a link between this card and a distant office is normally connected. Goes out after 15 seconds of link disconnection. RED Red Remains lit when detecting PCM signal loss or...
Page 284
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-DAIB (DAI) NEAX2000 IVS2 Installation Procedure ManualPage 258ND-70928 (E), Issue 1.0 Switch Settings SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SENSE (Rotary SW) 0-FAlways set to 0 1-F Not used MB (Toggle SW) NOTE 1UP For make-busy For normal operation SW1 (Piano Key SW)1 Always set to OFF 2 Always set to OFF 3 Always set to OFF 4 Always set to OFF (Continued) 0 ON DOWN 4 3 2 1 OFF ON OFF OFF OFF OFF
Page 285
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-DAIB (DAI) NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 259 SW2 (DIP SW) 1ONControl channel signaling data transmission speed: 48kbps Control channel signaling data transmission speed: 64kbps 2ONDTI frame configuration: 12-Multi Fram e DTI frame configuration: 24-Multi Fram e 3ON Line code: AMI with ZCS Line code: B8ZS 4ONSetting of control signal time slot NOTE 2, NOTE 3 5ON 6ON 7 OFF 8ON (Continued) SWITCH NAMESWITCH...
Page 286
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-DAIB (DAI) NEAX2000 IVS2 Installation Procedure ManualPage 260ND-70928 (E), Issue 1.0 The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. NOTE 1: When the power is on, flip the MB switch to ON (UP position) before plugging/unplug- ging the circuit card. NOTE...
Page 287
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-DAIC (DAI) NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 261 PN-DAIC (DAI) Location of Lamps, Switches, and Connectors Lamp Indications LAMP NAMECOLOR FUNCTION RUN Green Flashes at 120 IPM while this card is operating normally. LINK Green Remains lit when the following connection are normal. Control channel link between the DAIA card and DAIB card. Connection between the opposite DAIC card. Goes out after 15 seconds of link...
Page 288
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-DAIC (DAI) NEAX2000 IVS2 Installation Procedure ManualPage 262ND-70928 (E), Issue 1.0 Switch Settings SWITCHNAME SWITCH NUMBER SETTING POSITION FUNCTION CHECK MB (Toggle SW) N OTE UP For make-busy For normal operation SW1 (Piano Key SW) 1 Always set to OFF 2 Always set to OFF 3 Always set to OFF 4 Always set to OFF SW2 (DIP SW) 1 Not used 2ON DTI frame configuration: 12-Multi Fram e DTI frame configuration: 24-Multi Fram e 3 ON Line code: AMI...
Page 289
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-DAIC (DAI) NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 263 The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. NOTE: When the power is on, flip MB switch to ON (UP position) before plugging/unplugging the circuit card. SW3 (DIP...
Page 290
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-DAID (DAI) NEAX2000 IVS2 Installation Procedure ManualPage 264ND-70928 (E), Issue 1.0 PN-DAID (DAI) Location of Lamps, Switches, and Connectors Lamp Indications LAMP NAMECOLOR FUNCTION RUN Green Flashes at 120 IPM while this card is operating normally. LINK Green Remains lit when a link between this card and a distant office is normally connected. Goes out after 15 seconds of link disconnection. RMT Red Remains lit when receiving the alarm signal from a...