Page 331
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-SC00 (CCH) NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 305 Switch Settings SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SENSE (Rotary SW) NOTE 14-F Set the switch to match the AP Number (04-31) to be set by CM05. 0-3 Not used MB (Toggle SW) NOTE 2UP For make-busy For normal operation SW0 (Piano Key SW)1ON Loop-back test For normal operation 2ON Analog interface OFF Digital interface 3ONRS-232C RTS signal (to MODEM)...
Page 332
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-SC00 (CCH) NEAX2000 IVS2 Installation Procedure ManualPage 306ND-70928 (E), Issue 1.0 The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. NOTE 1: Set the groove on the switch to the desired position. NOTE 2: When the power is on, flip the MB switch to ON (UP...
Page 333
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-SC01 (DCH) NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 307 PN-SC01 (DCH) Locations of Lamps, Switches, and Connectors Lamp Indications LAMP NAMECOLOR FUNCTION RUN Green Flashes at 120 IPM while this card is operating normally. LC Green Remains lit when communications are normally ongoing with the D channel data links connected. LPB Green Not used SENSE RUN MB SW0 LC LPB SW1
Page 334
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-SC01 (DCH) NEAX2000 IVS2 Installation Procedure ManualPage 308ND-70928 (E), Issue 1.0 Switch Settings SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SENSE (Rotary SW) NOTE 14-F Set the switch to match the AP Number (04-31) to be set by CM05. 0-3 Not used MB (Toggle SW) NOTE 2UP For make-busy For normal operation SW0 (Piano Key SW)1 Always set to OFF 2 Always set to OFF 3 Always set to OFF 4ON AP No. 04-15 OFF AP No. 20-31 (Continued) F 4 AP...
Page 335
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-SC01 (DCH) NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 309 The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. NOTE 1: Set the groove on the switch to the desired position. NOTE 2: When the power is on, flip the MB switch to ON...
Page 336
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-SC03 (ICH) NEAX2000 IVS2 Installation Procedure ManualPage 310ND-70928 (E), Issue 1.0 PN-SC03 (ICH) Locations of Lamps, Switches, and Connectors Lamp Indications LAMP NAMECOLOR FUNCTION RUN Green Flashes at 120 IPM while this card is operating normally. DOPE7 Green Remains lit when No. 7 circuit D channel link is connected. DOPE6 Green Remains lit when No. 6 circuit D channel link is connected. DOPE5 Green Remains lit when No. 5 circuit D channel link is...
Page 337
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-SC03 (ICH) NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 311 Switch Settings The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. NOTE 1: Set the groove on the switch to the desired position. NOTE 2: When the power is on, flip the...
Page 338
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-SC03-A (CSH) NEAX2000 IVS2 Installation Procedure ManualPage 312ND-70928 (E), Issue 1.0 PN-SC03-A (CSH) Locations of Lamps, Switches, and Connectors Lamp Indications LAMP NAMECOLOR FUNCTION RUN Green Flashes at 120 IPM while this card is operating normally. DOPE7 Green Remains lit when No. 7 circuit D channel link is connected. DOPE6 Green Remains lit when No. 6 circuit D channel link is connected. DOPE5 Green Remains lit when No. 5 circuit D channel...
Page 339
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-SC03-A (CSH) NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 313 Switch Settings The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. NOTE 1: Set the groove on the switch to the desired position. NOTE 2: When the power is on, flip the...
Page 340
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PZ-M537 (EXPMEM) NEAX2000 IVS2 Installation Procedure ManualPage 314ND-70928 (E), Issue 1.0 PZ-M537 (EXPMEM) Locations of Lamps, Switches, and Connectors FA C E REAR CONNR: To CONN connector on PN-CP14 (MP) or PN-AP00-B (AP00) CONNR SW