CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-24PRTA (PRT) NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 295 Lamp Indications Switch Settings LAMP NAMECOLOR FUNCTION RUN Green Flashes at 120 IPM while this card is operating normally. LC Green Remains lit when communications are normally ongoing with the D channel data links connected. LPB–Not used CRC Red Remains lit when detecting Cyclic Redundancy Checking (CRC) errors. PCM Red Remains lit when detecting PCM signal...
Page 322
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-24PRTA (PRT) NEAX2000 IVS2 Installation Procedure ManualPage 296ND-70928 (E), Issue 1.0 MB (Toggle SW) NOTE 2UP For make-busy For normal operation SW0 (Piano Key SW) 1 NOTE 3 NOTE 4ONSource clock signal from network is sent to the PLO 0 input on MP card. OFFSource clock signal from network is not sent to the PLO 0 input on MP card. 2 NOTE 3 NOTE 4ONSource clock signal from network is sent to the PLO 1 input on MP card. OFFSource clock signal from...
Page 323
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-24PRTA (PRT) NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 297 SW1 (Piano Key SW) NOTE 41 Not used 2 Not used 3 Not used 4ON AP No. 04-15 OFF AP No. 20-31 SW2 (DIP SW) 1 Always set to OFF 2[North America only for AT&T] ONDeletion of Area Code on International Outgoing call OFFNo deletion of Area Code on International Outgoing call [Australia/Other countries] Always set to OFF 3 Always set to OFF 4 Always set to OFF 5 Always set...
Page 324
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-24PRTA (PRT) NEAX2000 IVS2 Installation Procedure ManualPage 298ND-70928 (E), Issue 1.0 The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. NOTE 1: Set the groove on the switch to the desired position. NOTE 2: When the power is on, flip the MB switch to ON...
Page 325
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-24PRTA (PRT) NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 299 NOTE 3: Set SW0-1 and SW0-2 as follows: NOTE 4: When the PBX is a clock source office, set the SW0-1 and SW0-2 on all the PRT cards mounted in PIM0 to “OFF”. NOTE 5: Mount the PRT card which receives a source clock signal into PIM 0. CONDITIONSPRT0 PRT1 PRT2 PRT3 PRT4 REMARKS SW 0-1SW 0-2SW 0-1SW 0-2SW 0-1SW 0-2SW 0-1SW 0-2SW 0-1SW 0-2 When one PRT is provided.ON...
Page 326
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-4RSTB (MFR) NEAX2000 IVS2 Installation Procedure ManualPage 300ND-70928 (E), Issue 1.0 PN-4RSTB (MFR) Locations of Lamps, Switches, and Connectors Lamp Indications LAMP NAMECOLOR FUNCTION RUN Green Flashes at 120 IPM while this card is operating normally. OPE0-3 RedRemains lit when the corresponding circuit is in use. Flashes at 60 IPM when the corresponding circuit is in make- busy state or the system data for this card is not assigned. SENSE RUN MB...
Page 327
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-4RSTB (MFR) NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 301 Switch Settings NOTE 1: Set the groove on the switch to the desired position. NOTE 2: When the power is on, flip the MB switch to ON (UP position) before plugging/unplug- ging the circuit card. SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SENSE (Rotary SW) NOTE 14-F Set the switch to match the AP Number (04-31) to be set by CM05 0-3 Not used MB (Toggle SW)...
Page 328
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-4RSTC (CIR) NEAX2000 IVS2 Installation Procedure ManualPage 302ND-70928 (E), Issue 1.0 PN-4RSTC (CIR) Locations of Lamps, Switches, and Connectors Lamp Indications LAMP NAMECOLOR FUNCTION RUN Green Flashes at 120 IPM while this card is operating normally. BL0-3 Red Remains lit when receiving a CALLER ID (CLASS SM) signal. SENSE RUN MB BL3 BL2 BL1 BL0 SW1 JP0
Page 329
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-4RSTC (CIR) NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 303 Switch Settings NOTE 1: Set the groove on the switch to the desired position. NOTE 2: When the power is on, flip the MB switch to ON (UP position) before plugging/unplug- ging the circuit card. SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SENSE (Rotary SW) NOTE 14-F Set the switch to match the AP Number (04-15) to be set by CM05. 0-3 Not used MB (Toggle...
Page 330
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-SC00 (CCH) NEAX2000 IVS2 Installation Procedure ManualPage 304ND-70928 (E), Issue 1.0 PN-SC00 (CCH) Locations of Lamps, Switches, and Connectors Lamp Indications LAMP NAMECOLOR FUNCTION RUN Green Flashes at 120 IPM while this card is operating normally. LC Green Remains lit when communications are normally ongoing with the common signalling channel data links connected. LPB Green Remains lit when a loop-back test is in progress. RS SENSE RUN MB SW0 LC...