CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-DAIF (DAI) NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 275 Switch Settings SWITCH NAME SWITCH NUMBER SETTING POSITION FUNCTION CHECK MB (Toggle SW) N OTE UP For make-busy For normal operation SW1 (Piano Key SW) 1 Always set to OFF 2 ON Line impedance: 75 ohms (For coaxial cable) Line impedance: 120 ohms (For twisted-pair cable) 3 Always set to OFF 4 Always set to OFF (Continued) ON DOWN 4 3 2 1 OFF ON OFF OFF OFF OFF
Page 302
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-DAIF (DAI) NEAX2000 IVS2 Installation Procedure ManualPage 276ND-70928 (E), Issue 1.0 SW2 (DIP SW) 1ONControl channel signaling data transmission speed: 48kbps Control channel signaling data transmission speed: 64kbps 2ONCRC Synchronization Detection Timer is provided. CRC Synchronization Detection Timer is not provided. 3ON CRC4 Check is provided. CRC4 Check is not provided. 4 Not used 5 Not used 6 Not used 7 Not used 8 Not used (Continued) SWITCH...
Page 303
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-DAIF (DAI) NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 277 The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. NOTE: When the power is on, flip the MB switch to ON (UP position) before plugging/unplug- ging the circuit card. SW3...
Page 304
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-24DTA-C (DTI) NEAX2000 IVS2 Installation Procedure ManualPage 278ND-70928 (E), Issue 1.0 PN-24DTA-C (DTI) Locations of Lamps, Switches, and Connectors SENSE RUN MB CRC PCM FRM RMT AIS BL SW1 SW0 JRR1 AISS MAS JPR0 JPS
Page 305
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-24DTA-C (DTI) NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 279 Lamp Indications LAMP NAMECOLOR FUNCTION RUN Green Flashes at 120 IPM while this card is operating normally. CRC Red Remains lit when detecting Cyclic Redundancy Checking (CRC) errors. PCM Red Remains lit when detecting PCM signal loss. FRM Red Remains lit when detecting Frame Alignment signal loss. RMT Red Remains lit when receiving Frame Alignment signal loss...
Page 306
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-24DTA-C (DTI) NEAX2000 IVS2 Installation Procedure ManualPage 280ND-70928 (E), Issue 1.0 Switch Settings SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SENSE (Rotary SW) NOTE 10-3 Not used 4-F Set the switch to match the AP Number (04-31) to be set by CM05. MB (Toggle SW) NOTE 2UP For make-busy For normal operation (Continued) F 4 AP No.SW1-4: ON 04 05 06 07 08 09 10 11 12 13 14 15 SW1-4: OFF 20 21 22 23 24 25 26 27 28 29 30 31 SW No....
Page 307
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-24DTA-C (DTI) NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 281 SW0 (Piano Key SW) 1 NOTE 3 NOTE 4ONSource clock signal from network is sent to the PLO 0 input on MP card. OFFSource clock signal from network is not sent to the PLO 0 input on MP card. 2 NOTE 3 NOTE 4ONSource clock signal from network is sent to the PLO 1 input on MP card. OFFSource clock signal from network is not sent to the PLO 1 input on MP card....
Page 308
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-24DTA-C (DTI) NEAX2000 IVS2 Installation Procedure ManualPage 282ND-70928 (E), Issue 1.0 The figure in the SWITCH NAME column and the position in in the SETTING POSITION- column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned.SW1 (Piano Key SW) NOTE 41 Not used 2 Not used 3 Not used 4ON AP No. 04-15 OFF AP No. 20-31 JPR0 (Jumper pin)...
Page 309
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-24DTA-C (DTI) NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 283 NOTE 1: Set the groove on the switch to the desired position. NOTE 2: When the power is on, flip the MB switch to ON (UP position) before plugging/unplug- ging the circuit card. NOTE 3: Set SW0-1 and SW0-2 as follows: NOTE 4: When the PBX is a clock source office, set the SW0-1 and SW0-2 on all the DTI cards mounted in PIM0 to “OFF”. NOTE 5: Mount the DTI card which...
Page 310
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-30DTC-A (DTI) NEAX2000 IVS2 Installation Procedure ManualPage 284ND-70928 (E), Issue 1.0 PN-30DTC-A (DTI) Locations of Lamps, Switches, and Connectors SENSE RUN MB SW PCM FRM MFRM RMT MRMT AIS BL JP JPSJPR