CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PN-2BRTC (BRT)
NEAX2000 IVS2 Installation Procedure Manual
ND-70928 (E), Issue 1.0Page 245
Switch Settings
SWITCH NAMESWITCH 
NUMBERSETTING 
POSITIONFUNCTION CHECK
SENSE
(Rotary SW)
NOTE 14-F Set the switch to match the AP Number (04-31) to
be set by CM05.
0-3 Not used
MB (Toggle SW)
NOTE 2UP For make-busy
For normal operation
SW0, SW10
(DIP SW)
1For terminating the transmitting side 
of channels B1 and B2 with 100 
ohms.
OFFTo remove the terminating...

Page 272

CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PN-2BRTC (BRT)
NEAX2000 IVS2 Installation Procedure ManualPage 246ND-70928 (E), Issue 1.0
The figure in the SWITCH NAME column and the position in   in the SETTING POSITION
column indicate the standard setting of the switch. When the switch is not set as shown by the
figure and  , the setting of the switch varies with the system concerned.
NOTE 1:
Set the groove on the switch to the desired position.
NOTE 2:
When the power is on, flip the MB switch to ON (UP...

Page 273

CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PN-2BRTC (BRT)
NEAX2000 IVS2 Installation Procedure Manual
ND-70928 (E), Issue 1.0Page 247
NOTE 3:
The system can supply clock signals from two clock supply routes.
In normal condition, the system synchronizes to the clock signals supplied on the PLO
0 of MP card via the Back Wiring Board, and if the clock signals are failed, the clock
supply route takes over to PLO1 automatically. Set SW11-2 and SW11-3 as follows.
NOTE 4:
When the system is a clock source...

Page 274

CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PN-CC01 (ETHER)
NEAX2000 IVS2 Installation Procedure ManualPage 248ND-70928 (E), Issue 1.0
PN-CC01 (ETHER)
Location of Lamps, Switches, and Connectors
RUN
MB
LINK 
XMT 
RCV 
RV P  
ERR
IP 10BASE-T
SW1SW2 

Page 275

CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PN-CC01 (ETHER)
NEAX2000 IVS2 Installation Procedure Manual
ND-70928 (E), Issue 1.0Page 249
Lamp Indications
Switch Settings
LAMP 
NAMECOLOR FUNCTION
RUN Green Flashes at 60 IPM while this card is operating normally.
LINK Green Remains lit when link is established.
XMT Green Remains lit when it is transmitting the data.
RCV Green Remains lit when it is receiving the data.
RVP Green Remains lit only when it is receiving the data with its own IP
address....

Page 276

CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PN-CC01 (ETHER)
NEAX2000 IVS2 Installation Procedure ManualPage 250ND-70928 (E), Issue 1.0
SW1 (DIP SW)
NOTE 2
SW1-5 (D11)
SW1-6 (D10)
SW1-7 (D9)
SW1-8 (D8)
1 (D15) ON
2 (D14) ON
3 (D13) ON
4 (D12) OFF
5 (D11)ON
OFF
6 (D10)ON
OFF
7 (D9)ON
OFF
8 (D8)ON
OFF
SW2 (DIP SW)
NOTE 21 (D7)ON
OFF
2 (D6)ON
OFF
3 (D5)ON
OFF
4 (D4)ON
OFF
5 (D3)ON
OFF
6 (D2)ON
OFF
7 (D1)ON
OFF
8 (D0)ON
OFF
SWITCH
NAMESWITCH
NUMBERSETTING
POSITIONFUNCTION CHECK
1
23
45
67
8ON
MAC ADDRESS...

Page 277

CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PN-CC01 (ETHER)
NEAX2000 IVS2 Installation Procedure Manual
ND-70928 (E), Issue 1.0Page 251
NOTE 1:
When the power is on, flip the MB switch to ON (UP position) before plugging/unplug-
ging the circuit card.
NOTE 2:
Each equipment must have a unique MAC address to distinguish between systems.
Therefore, when more than one PBX is installed in the same network, assign the lower
4 digits of the following MAC address by SW1 and SW2 to prevent duplicate address-...

Page 278

CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PN-DAIA (DAI)
NEAX2000 IVS2 Installation Procedure ManualPage 252ND-70928 (E), Issue 1.0
PN-DAIA (DAI)
Location of Lamps, Switches, and Connectors
Lamp Indications
LAMP 
NAMECOLOR FUNCTION
RUN Green Flashes at 120 IPM while this card is operating normally.
LINK Green Remains lit when a link between this card and a distant office is 
normally connected.
Goes out after 15 seconds of link disconnection.
RED Red Remains lit when detecting PCM signal loss or...

Page 279

CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PN-DAIA (DAI)
NEAX2000 IVS2 Installation Procedure Manual
ND-70928 (E), Issue 1.0Page 253
Switch Settings
SWITCH NAMESWITCH 
NUMBERSETTING 
POSITIONFUNCTION CHECK
SENSE
(Rotary SW)
NOTE 10-FFP (Firmware Processor) Number setting for the
DAIA card.
By this setting, the system regards the DAIA card
and the opposite DAIB card as one Firmware Pro-
cessor.
0 Not used
1FP No. 1
2FP No. 2
3FP No. 3
4 – F Not used
MB (Toggle SW)
NOTE 2UP For make-busy
For normal...

Page 280

CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PN-DAIA (DAI)
NEAX2000 IVS2 Installation Procedure ManualPage 254ND-70928 (E), Issue 1.0
SW2 (DIP SW)
1ONControl channel signaling data 
transmission speed: 48kbps
Control channel signaling data 
transmission speed: 64kbps
2ONDTI frame configuration: 12-Multi 
Fram e
DTI frame configuration: 24-Multi 
Fram e
3ON Line code: AMI with ZCS
Line code: B8ZS
4ONSetting of control signal time slot
NOTE 4, NOTE 5 5ON
6ON
7
OFF
8ON
(Continued)
SWITCH NAMESWITCH...