CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PN-AP01 (AP01)
NEAX2000 IVS2 Installation Procedure Manual
ND-70928 (E), Issue 1.0Page 235
PN-AP01 (AP01)
Locations of Lamps, Switches, and Connectors
Lamp Indications
LAMP NAME COLOR FUNCTION
RUN Green Flashes at 120 IPM while this card is operating normally.
L0-L3 L3 Green Indication of CTS signal status on RS-232C port.
L2 Indication of DCD signal status on RS-232C port.
L1 Indication of TXD signal status on RS-232C port.
L0 Indication of RXD signal...

Page 262

CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PN-AP01 (AP01)
NEAX2000 IVS2 Installation Procedure ManualPage 236ND-70928 (E), Issue 1.0
Switch Settings
SWITCH NAMESWITCH 
NUMBERSETTING 
POSITIONFUNCTION CHECK
SENSE
(Rotary SW)
NOTE 14-F Set the switch to match the AP Number (04-15) to
be set by CM05.
0-3 Not used
MB (Toggle SW)
NOTE 2UP For make-busy
For normal operation
SW1
(Piano Key SW)
1For normal operation
OFF Not used
2For normal operation
OFF Not used
3For normal operation
OFF Not used
4For...

Page 263

CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PN-AP01 (AP01)
NEAX2000 IVS2 Installation Procedure Manual
ND-70928 (E), Issue 1.0Page 237
The figure in the SWITCH NAME column and the position in    in the SETTING POSITION
column indicate the standard setting of the switch. When the switch is not set as shown by the
figure and   , the setting of the switch varies with the system concerned.
NOTE 1:
Set the groove on the switch to the desired position.
NOTE 2:
When the power is on, flip the MB switch to ON...

Page 264

CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PN-BRTA (BRT)
NEAX2000 IVS2 Installation Procedure ManualPage 238ND-70928 (E), Issue 1.0
PN-BRTA (BRT)
Locations of Lamps, Switches, and Connectors
SENSE
RUN
MB
SW1
SW0B1
B2
D
ALM 

Page 265

CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PN-BRTA (BRT)
NEAX2000 IVS2 Installation Procedure Manual
ND-70928 (E), Issue 1.0Page 239
Lamp Indications
LAMP 
NAMECOLOR FUNCTION
RUN Green Flashes at 120 IPM while this card is operating normally.
B1 Green B1 channel status
ON: Busy
OFF: Idle
Flash (60 IPM):  Make Busy
B2 Green B2 channel status
ON: Busy
OFF: Idle
Flash (60 IPM):  Make Busy
D Green D channel status
ON: Busy
OFF: Idle
ALM Red Transmission line fault status
ON: Line fault
OFF: Normal...

Page 266

CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PN-BRTA (BRT)
NEAX2000 IVS2 Installation Procedure ManualPage 240ND-70928 (E), Issue 1.0
Switch Settings
SWITCH NAMESWITCH 
NUMBERSETTING 
POSITIONFUNCTION CHECK
SENSE
(Rotary SW)
NOTE 14-F Set the switch to match the AP Number (04-15) to
be set by CM05.
0-3 Not used
MB (Toggle SW)
NOTE 2UP For make-busy
For normal operation
SW0 (DIP SW)
1For normal operation 
OFF Not used
2
NOTE 3
NOTE 4ONSource clock signal from network is 
sent to the PLO of MP according...

Page 267

CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PN-BRTA (BRT)
NEAX2000 IVS2 Installation Procedure Manual
ND-70928 (E), Issue 1.0Page 241
The figure in the SWITCH NAME column and the position in   in the SETTING POSITION
column indicate the standard setting of the switch. When the switch is not set as shown by the
figure and  , the setting of the switch varies with the system concerned.
NOTE 1:
Set the groove on the switch to the desired position.
NOTE 2:
When the power is on, flip the MB switch to ON (UP...

Page 268

CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PN-BRTA (BRT)
NEAX2000 IVS2 Installation Procedure ManualPage 242ND-70928 (E), Issue 1.0
NOTE 3:
Set the SW0-2 and SW0-3 as follows:
NOTE 4:
When the system is a clock source office, set the SW0-2 and SW0-3 on all the BRT
cards mounted in PIM0 to “OFF”.
NOTE 5:
Mount the BRT card which receives a source clock signals into PIM0. CONDITIONSBRT0 BRT1 BRT2 ---- BRT11
REMARKS
SW
0-2SW
0-3SW
0-2SW
0-3SW
0-2SW
0-3----SW
0-2SW
0-3
When one 
BRT is 
provided.ON ONMP...

Page 269

CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PN-2BRTC (BRT)
NEAX2000 IVS2 Installation Procedure Manual
ND-70928 (E), Issue 1.0Page 243
PN-2BRTC (BRT)
Locations of Lamps, Switches, and Connectors
SENSE
RUN
MB
B21 
B11 
D1 
ALM1 
B20 
B10 
D0 
ALM0
SW0 SW11
SW10 

Page 270

CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PN-2BRTC (BRT)
NEAX2000 IVS2 Installation Procedure ManualPage 244ND-70928 (E), Issue 1.0
Lamp Indications
LAMP 
NAMECOLOR FUNCTION
RUN Green Flashes at 120 IPM while this card is operating normally.
B21 Red No.1 Circuit B2 channel status
ON: Busy
OFF: Idle
Flash (60 IPM):  Make Busy
B11 Red B1 channel status
ON: Busy
OFF: Idle
Flash (60 IPM):  Make Busy
D1 Green D channel status
ON: Busy
OFF: Idle
ALM1 Red Transmission line fault status
ON: Line fault
OFF:...