CHAPTER 2 INSTALLATION
SMDR/PMS/MCI/CIS Printer/Hotel Printer (AP00)
NEAX2000 IVS2 Installation Procedure Manual
ND-70928 (E), Issue 1.0Page 195

Connection via MODEM
When the cable length between the PBX and the terminal is more than 15 m (49.2 ft), MO-
DEMs are required. Use RS RORM-4(S) CA-A as shown below. See also Figure 2-99.
Figure 2-101  SMDR/PMS/MCI Terminal Connection via MODEMs
RS0 - RS3
PN- PBX
(PIM0 - PIM7)
RS NORM-4S CA-A: 
4m (13.1 ft.)MODEM MODEM2P
MORE THAN 15m (49.2 ft.) 
MODEM: FULL...

Page 222

CHAPTER 2 INSTALLATION
SMDR/PMS/MCI/CIS Printer/Hotel Printer (AP00)
NEAX2000 IVS2 Installation Procedure ManualPage 196ND-70928 (E), Issue 1.0
(2) CIS Printer/Hotel Printer

Direct Connection
Connect a maximum of two printers to the PN-AP00-B using the RS PRT-15(S) CA-A as 
shown below.
Figure 2-102  Printer Direct Connection

Connection via MODEM
When the cable length between the printer and the PBX is more than 15 m (49.2 ft.), MO-
DEMs are required.
Figure 2-103  Printer Connection via MODEMs...

Page 223

CHAPTER 2 INSTALLATION
SMDR/PMS/MCI/CIS Printer/Hotel Printer (AP00)
NEAX2000 IVS2 Installation Procedure Manual
ND-70928 (E), Issue 1.0Page 197
Figure 2-104  RS PRT-15 CA-A/RS PRT-15S CA-A
See Table 2-7.
05C-DTR
MAX. 15 m (49.2 ft.)
05B-GND 01-GND
05A-TXD 03-RXD
03B-CTS 20-DTR
03A-DSR
02B-GND 07-GND
DCB A
06 TXC
(1)XRXCTXC
(2)
05 X DTR GND TXD
04 (RT) X RXD RTS
03 X (ST) CTS DSR
02 ---- X GND DCD
01 X LALB X G25 ----
24 ----
23 ----
22 ----
21 ----
20 DTR
19 ----
18 ----
17 ----
16 ----
15 ----
14...

Page 224

CHAPTER 2 INSTALLATION
SMDR/PMS/MCI/CIS Printer/Hotel Printer (AP00)
NEAX2000 IVS2 Installation Procedure ManualPage 198ND-70928 (E), Issue 1.0
Table 2-7  RS-232C Connector Layout
PIN 
NO.SIGNAL-NAME
SIGNAL 
DIRECTIONMEANING
RS-232C JIS C6361ITU-T 
V. 2 4ANOTHER
1 AA (FG) 101 GND Frame Ground
2 BA SD 103 TXD DTE Send Data
3 BB RD 104 RXD DCE Receive Data
4 CA RS 105 RTS DTE Request to Send
5 CB CS 106 CTS DCE Clear to Send
6 CC DR 107 DSR DCE Data Set Ready
7 AB SG 102 GND Signal Ground
8 CF CD 109 DCD...

Page 225

CHAPTER 2 INSTALLATION
Mounting Circuit Cards
NEAX2000 IVS2 Installation Procedure Manual
ND-70928 (E), Issue 1.0Page 199
MOUNTING CIRCUIT CARDS
(1) Before mounting the circuit cards, confirm the following items.
Wrist Strap is connected to Frame Ground.
Switch settings of circuit cards are already completed. See CHAPTER 3.
The “SW1” switches of all PZ-PW121 cards are turned off.
(2) Mount circuit cards into their mounting positions according to the “Bay Face Layout” and 
“Port Assignment Table” given...

Page 226

CHAPTER 2 INSTALLATION
Mounting Circuit Cards
NEAX2000 IVS2 Installation Procedure ManualPage 200ND-70928 (E), Issue 1.0
(3) Fix the CARD STOPPER according to the following procedure.
STEP 1: After mounting all circuit cards slide the CARD STOPPER to the left.
STEP 2: Tighten the screws of the CARD STOPPER as shown below.
NOTE:
When sliding the PIM CARD STOPPER, loosen all of the screws securing the PIM
CARD STOPPER and the PZ-M542/PZ-M557 card (the screws need not to be re-
moved).
Figure 2-106...

Page 227

CHAPTER 2 INSTALLATION
System Initialization
NEAX2000 IVS2 Installation Procedure Manual
ND-70928 (E), Issue 1.0Page 201
SYSTEM INITIALIZATION
There are two methods for System Initialization. The first method is to Clear All
Data, except LEN000 as a CAT terminal, then program the System Data. The
second method is to use the Resident System Program, which causes the sys-
tem to configure itself automatically to the default settings, wherever the line/
trunk cards are installed.
NOTE 1:
See CHAPTER 3 for...

Page 228

CHAPTER 2 INSTALLATION
System Data Entry
NEAX2000 IVS2 Installation Procedure ManualPage 202ND-70928 (E), Issue 1.0
SYSTEM DATA ENTRY
There are two methods for data entry, using a Customer Administration Terminal
(CAT) or a Maintenance Administration Terminal (MAT).
NOTE:
For assigning system data, refer to the Command Manual.
CAT
Any Dterm can be assigned as a CAT through programming. The Dterm can still be used as a reg-
ular telephone when it is not in CAT mode. If the system is initialized by “C”...

Page 229

CHAPTER 2 INSTALLATION
MAT
NEAX2000 IVS2 Installation Procedure Manual
ND-70928 (E), Issue 1.0Page 203
To reset CAT mode:
While “COMMAND = -” is displayed on the LCD:
1. Lift the handset (off hook)
- SPKR/Speaker lamp turns off.
2. Restore the handset (on hook)
- CNF/Conf, FNC/Feature lamps turn off.
- LCD returns to clock.
MAT
Refer to the MATWorX User Guide.
Cofirming Lamp Indication
After system data entry, confirm proper operation of the system using indicator lamps.
RUN Lamp Flashing (120 IPM)...

Page 230

CHAPTER 2 INSTALLATION
Operation Test
NEAX2000 IVS2 Installation Procedure ManualPage 204ND-70928 (E), Issue 1.0
OPERATION TEST
Confirm the entered system data and hardware, including cable connection, by completing the
following operational tests.
Basic Connection Test at MDF
Station Line Test (Operator Call from all stations)
Central Office Trunk Test (Incoming, Outgoing)
Tie Line Trunk Test (Incoming, Outgoing)
Service Feature Test
Call Transfer
Step Call
Executive Right of Way (Executive Override)...