Page 221
CHAPTER 2 INSTALLATION SMDR/PMS/MCI/CIS Printer/Hotel Printer (AP00) NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 195 Connection via MODEM When the cable length between the PBX and the terminal is more than 15 m (49.2 ft), MO- DEMs are required. Use RS RORM-4(S) CA-A as shown below. See also Figure 2-99. Figure 2-101 SMDR/PMS/MCI Terminal Connection via MODEMs RS0 - RS3 PN- PBX (PIM0 - PIM7) RS NORM-4S CA-A: 4m (13.1 ft.)MODEM MODEM2P MORE THAN 15m (49.2 ft.) MODEM: FULL...
Page 222
CHAPTER 2 INSTALLATION SMDR/PMS/MCI/CIS Printer/Hotel Printer (AP00) NEAX2000 IVS2 Installation Procedure ManualPage 196ND-70928 (E), Issue 1.0 (2) CIS Printer/Hotel Printer Direct Connection Connect a maximum of two printers to the PN-AP00-B using the RS PRT-15(S) CA-A as shown below. Figure 2-102 Printer Direct Connection Connection via MODEM When the cable length between the printer and the PBX is more than 15 m (49.2 ft.), MO- DEMs are required. Figure 2-103 Printer Connection via MODEMs...
Page 223
CHAPTER 2 INSTALLATION SMDR/PMS/MCI/CIS Printer/Hotel Printer (AP00) NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 197 Figure 2-104 RS PRT-15 CA-A/RS PRT-15S CA-A See Table 2-7. 05C-DTR MAX. 15 m (49.2 ft.) 05B-GND 01-GND 05A-TXD 03-RXD 03B-CTS 20-DTR 03A-DSR 02B-GND 07-GND DCB A 06 TXC (1)XRXCTXC (2) 05 X DTR GND TXD 04 (RT) X RXD RTS 03 X (ST) CTS DSR 02 ---- X GND DCD 01 X LALB X G25 ---- 24 ---- 23 ---- 22 ---- 21 ---- 20 DTR 19 ---- 18 ---- 17 ---- 16 ---- 15 ---- 14...
Page 224
CHAPTER 2 INSTALLATION SMDR/PMS/MCI/CIS Printer/Hotel Printer (AP00) NEAX2000 IVS2 Installation Procedure ManualPage 198ND-70928 (E), Issue 1.0 Table 2-7 RS-232C Connector Layout PIN NO.SIGNAL-NAME SIGNAL DIRECTIONMEANING RS-232C JIS C6361ITU-T V. 2 4ANOTHER 1 AA (FG) 101 GND Frame Ground 2 BA SD 103 TXD DTE Send Data 3 BB RD 104 RXD DCE Receive Data 4 CA RS 105 RTS DTE Request to Send 5 CB CS 106 CTS DCE Clear to Send 6 CC DR 107 DSR DCE Data Set Ready 7 AB SG 102 GND Signal Ground 8 CF CD 109 DCD...
Page 225
CHAPTER 2 INSTALLATION Mounting Circuit Cards NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 199 MOUNTING CIRCUIT CARDS (1) Before mounting the circuit cards, confirm the following items. Wrist Strap is connected to Frame Ground. Switch settings of circuit cards are already completed. See CHAPTER 3. The “SW1” switches of all PZ-PW121 cards are turned off. (2) Mount circuit cards into their mounting positions according to the “Bay Face Layout” and “Port Assignment Table” given...
Page 226
CHAPTER 2 INSTALLATION Mounting Circuit Cards NEAX2000 IVS2 Installation Procedure ManualPage 200ND-70928 (E), Issue 1.0 (3) Fix the CARD STOPPER according to the following procedure. STEP 1: After mounting all circuit cards slide the CARD STOPPER to the left. STEP 2: Tighten the screws of the CARD STOPPER as shown below. NOTE: When sliding the PIM CARD STOPPER, loosen all of the screws securing the PIM CARD STOPPER and the PZ-M542/PZ-M557 card (the screws need not to be re- moved). Figure 2-106...
Page 227
CHAPTER 2 INSTALLATION System Initialization NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 201 SYSTEM INITIALIZATION There are two methods for System Initialization. The first method is to Clear All Data, except LEN000 as a CAT terminal, then program the System Data. The second method is to use the Resident System Program, which causes the sys- tem to configure itself automatically to the default settings, wherever the line/ trunk cards are installed. NOTE 1: See CHAPTER 3 for...
Page 228
CHAPTER 2 INSTALLATION System Data Entry NEAX2000 IVS2 Installation Procedure ManualPage 202ND-70928 (E), Issue 1.0 SYSTEM DATA ENTRY There are two methods for data entry, using a Customer Administration Terminal (CAT) or a Maintenance Administration Terminal (MAT). NOTE: For assigning system data, refer to the Command Manual. CAT Any Dterm can be assigned as a CAT through programming. The Dterm can still be used as a reg- ular telephone when it is not in CAT mode. If the system is initialized by “C”...
Page 229
CHAPTER 2 INSTALLATION MAT NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 203 To reset CAT mode: While “COMMAND = -” is displayed on the LCD: 1. Lift the handset (off hook) - SPKR/Speaker lamp turns off. 2. Restore the handset (on hook) - CNF/Conf, FNC/Feature lamps turn off. - LCD returns to clock. MAT Refer to the MATWorX User Guide. Cofirming Lamp Indication After system data entry, confirm proper operation of the system using indicator lamps. RUN Lamp Flashing (120 IPM)...
Page 230
CHAPTER 2 INSTALLATION Operation Test NEAX2000 IVS2 Installation Procedure ManualPage 204ND-70928 (E), Issue 1.0 OPERATION TEST Confirm the entered system data and hardware, including cable connection, by completing the following operational tests. Basic Connection Test at MDF Station Line Test (Operator Call from all stations) Central Office Trunk Test (Incoming, Outgoing) Tie Line Trunk Test (Incoming, Outgoing) Service Feature Test Call Transfer Step Call Executive Right of Way (Executive Override)...