CHAPTER 2 INSTALLATION
Power Failure Transfer (8PFT)
NEAX2000 IVS2 Installation Procedure Manual
ND-70928 (E), Issue 1.0Page 185
Power Failure Transfer (8PFT)
(1) Connection Outline
Figure 2-91  PFT Connection Outline (8PFT)
NOTE:Using the PN-AUCA card (long line card) instead of the PN-8LC card is not recom-
mended due to the variations from Central Office to the PBX; line quality cannot be as-
sured.
PZ-8PFTB
PBX
MDF MDFMDF MDF
TO C.O. 
LINE PN-8LC PN-8COT
TEL
NOTE 

Page 212

CHAPTER 2 INSTALLATION
Power Failure Transfer (8PFT)
NEAX2000 IVS2 Installation Procedure ManualPage 186ND-70928 (E), Issue 1.0
(2) Installation of PZ-8PFTB
STEP 1: Mount the PZ-8PFTB card into the PFT slot of the PIM.
STEP 2: Connect the champ connectors of 25-pair cables to the PFT0 and PFT1 connectors on
the PZ-8PFTB card as shown below.
Figure 2-92  Connection of 25-Pair Cable and PZ-8PFTB
PFT1 CONNECTOR
CHAMP CONNECTOR ATTACHED TO PZ-8PFTB 
25-PAIR CABLE
To  M D F  
(SEE STEP 3) PFT0 CONNECTOR...

Page 213

CHAPTER 2 INSTALLATION
Power Failure Transfer (8PFT)
NEAX2000 IVS2 Installation Procedure Manual
ND-70928 (E), Issue 1.0Page 187
STEP 3: Connect the 25-pair cables on the MDF.

This figure shows the PFT connector pin assignment for each PFT circuit number
(No. 0 - No. 7).
Figure 2-93  PFT Connector Pin Assignment
PFT0
1 Sta. R0 26 Sta. T0
2 8LC. R0 27 8LC. T0
3 C.O. R0 28 C.O. T0
4 8COT. R0 29 8COT. T0
5 Sta. R1 30 Sta. T1
6 8LC. R1 31 8LC. T1
7 C.O. R1 32 C.O. T1
8 8COT. R1 33 8COT. T1
9 Sta. R2 34...

Page 214

CHAPTER 2 INSTALLATION
Power Failure Transfer (8PFT)
NEAX2000 IVS2 Installation Procedure ManualPage 188ND-70928 (E), Issue 1.0

This figure shows MDF cross connection for No. 0 circuit on the PZ-8PFTB.
Figure 2-94  MDF Cross Connection for PFT (8PFT) (1 of 2)
TO STATION
272
338
261
272 261
338 JP PIM0
LT 0 0
35
41
349
35 349
41
T1LEN009
(No. 1)R1
T0LEN008
(No. 0)R0
T7LEN015
(No. 7)R7
PN-8COT
LT 0 1
T1LEN001
(No. 1)R1
T0LEN000
(No. 0)R0
T7LEN007
(No. 7)R7
PN-8LC
PZ-PW121
–27V
G261 Sta. R0
Sta. T0
283...

Page 215

CHAPTER 2 INSTALLATION
Power Failure Transfer (8PFT)
NEAX2000 IVS2 Installation Procedure Manual
ND-70928 (E), Issue 1.0Page 189
Figure 2-94  MDF Cross Connection for PFT (8PFT) (2 of 2)
3LTC0 CONNECTOR
2 PFT1 CONNECTOR
24 49 E
25 50–27V49 E 24
50–27V 25
PFT1 (J)
26 Sta. T0 1 Sta. R0
27 8LC. T0 2 8LC. R0
28 C.O. T0 3 C.O. R0
29 8COT. T0 4 8COT. R0 1 Sta. R0 26 Sta. T0
2 8LC. R0 27 8LC. T0
3 C.O. R0 28 C.O. T0
4 8COT. R0 29 8COT. T0 
PFT0 (P)
TO  S TAT IO N
TO  P N - 8 L C
TO  C.O. L IN E
TO  P N - 8 C...

Page 216

CHAPTER 2 INSTALLATION
Alarm Display Panel (MP)
NEAX2000 IVS2 Installation Procedure ManualPage 190ND-70928 (E), Issue 1.0
Alarm Display Panel (MP)
Figure 2-95  MDF Cross Connection for Alarm Display Panel
REAR
ALARM DISPLAY PANEL
26 1
50 MN 25 MJ
LT C 0  ( J )
126
25 MJ 50 MN
LT C 0  ( P )
PWRMJMIN
FRONT25
5025
50MJ
MN
–27V
GPN-CP14PIM0 MDF
LT C 0
P J
PZ-PW121 

Page 217

CHAPTER 2 INSTALLATION
Built-in SMDR (MP)
NEAX2000 IVS2 Installation Procedure Manual
ND-70928 (E), Issue 1.0Page 191
Built-in SMDR (MP)
The MP card provides a RS-232C interface port for SMDR connection.
No.0 Port : Async.: 1200/2400/4800/9600/19200 bps

Direct connection
Connect the SMDR terminal to the RS 0 Port of the PN-CP14 card using the RS RVS-15 (S)
CA-A/RS RVS-4 (S) CA-A/RS RVS-4 (S) CA-C as shown below.
Figure 2-96  SMDR Terminal Direct Connection

Connection via MODEM
When the cable length...

Page 218

CHAPTER 2 INSTALLATION
Built-in SMDR (MP)
NEAX2000 IVS2 Installation Procedure ManualPage 192ND-70928 (E), Issue 1.0
Figure 2-98  RS RVS-15 CA-A/RS RVS-15S CA-A/
RS RVS-4 CA-A/RS RVS-4 CA-C/
RS RVS-4S CA-A/RS RVS-4S CA-C
NOTE:
If the SMDR terminal does not send DTR or RTS signal, cut the signal lead marked by
X in the D-Sub connector (SMDR terminal side) as shown in the wiring diagram above.
See Table 2-7.
05A-TXD
05B-GND
06A-TXC (2)
06A-TXC (2)
06B-RXC
06D-TXC (1)
04B-RXD
04A-RTS
03-RXD
01-GND
06-DSR...

Page 219

CHAPTER 2 INSTALLATION
Built-in SMDR (MP)
NEAX2000 IVS2 Installation Procedure Manual
ND-70928 (E), Issue 1.0Page 193
Figure 2-99  RS NORM-4 CA-A/RS NORM-4S CA-A
See Table 2-7.
05A-TXD
05B-GND
0
5C-DTR
06A-TXC (2)
06B-RXC
06D-TXC (1)
04B-RXD
04A-RTS
02-TXD
01-GND
20-DTR
15-TXC (2)
17-RXC
03-RXD
04-RTS
24-TXC (1)
02B-GND
03A-DSR
03B-CTS
02A-DCD
01C-LALB
07-GND
06-DSR
05-CTS
08-DCD
18-LALB
DC B A
06 TXC (1) X RXC TXC (2)
05 X DTR GND TXD
04 (RT) X RXD RTS
03 X (ST) CTS DSR
02 ---- X GND DCD
01 X LALB X G...

Page 220

CHAPTER 2 INSTALLATION
SMDR/PMS/MCI/CIS Printer/Hotel Printer (AP00)
NEAX2000 IVS2 Installation Procedure ManualPage 194ND-70928 (E), Issue 1.0
SMDR/PMS/MCI/CIS Printer/Hotel Printer (AP00)
The PN-AP00-B card provides 4 RS-232C interface ports for SMDR, PMS, MCI, CIS Printer, Ho-
tel Printer.
(1) SMDR/PMS/MCI (VMS)

Direct Connection
Connect the terminal to the RS0-RS3 port of the PN-AP00-B card using the RS RVS-15 (S) 
CA-A/RS RVS-4 (S) CA-A/RS RVS-4 (S) CA-C as shown below. See also Figure 2-98....