CHAPTER 2 INSTALLATION Power Failure Transfer (8PFT) NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 185 Power Failure Transfer (8PFT) (1) Connection Outline Figure 2-91 PFT Connection Outline (8PFT) NOTE:Using the PN-AUCA card (long line card) instead of the PN-8LC card is not recom- mended due to the variations from Central Office to the PBX; line quality cannot be as- sured. PZ-8PFTB PBX MDF MDFMDF MDF TO C.O. LINE PN-8LC PN-8COT TEL NOTE
Page 212
CHAPTER 2 INSTALLATION Power Failure Transfer (8PFT) NEAX2000 IVS2 Installation Procedure ManualPage 186ND-70928 (E), Issue 1.0 (2) Installation of PZ-8PFTB STEP 1: Mount the PZ-8PFTB card into the PFT slot of the PIM. STEP 2: Connect the champ connectors of 25-pair cables to the PFT0 and PFT1 connectors on the PZ-8PFTB card as shown below. Figure 2-92 Connection of 25-Pair Cable and PZ-8PFTB PFT1 CONNECTOR CHAMP CONNECTOR ATTACHED TO PZ-8PFTB 25-PAIR CABLE To M D F (SEE STEP 3) PFT0 CONNECTOR...
Page 213
CHAPTER 2 INSTALLATION Power Failure Transfer (8PFT) NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 187 STEP 3: Connect the 25-pair cables on the MDF. This figure shows the PFT connector pin assignment for each PFT circuit number (No. 0 - No. 7). Figure 2-93 PFT Connector Pin Assignment PFT0 1 Sta. R0 26 Sta. T0 2 8LC. R0 27 8LC. T0 3 C.O. R0 28 C.O. T0 4 8COT. R0 29 8COT. T0 5 Sta. R1 30 Sta. T1 6 8LC. R1 31 8LC. T1 7 C.O. R1 32 C.O. T1 8 8COT. R1 33 8COT. T1 9 Sta. R2 34...
Page 214
CHAPTER 2 INSTALLATION Power Failure Transfer (8PFT) NEAX2000 IVS2 Installation Procedure ManualPage 188ND-70928 (E), Issue 1.0 This figure shows MDF cross connection for No. 0 circuit on the PZ-8PFTB. Figure 2-94 MDF Cross Connection for PFT (8PFT) (1 of 2) TO STATION 272 338 261 272 261 338 JP PIM0 LT 0 0 35 41 349 35 349 41 T1LEN009 (No. 1)R1 T0LEN008 (No. 0)R0 T7LEN015 (No. 7)R7 PN-8COT LT 0 1 T1LEN001 (No. 1)R1 T0LEN000 (No. 0)R0 T7LEN007 (No. 7)R7 PN-8LC PZ-PW121 –27V G261 Sta. R0 Sta. T0 283...
Page 215
CHAPTER 2 INSTALLATION Power Failure Transfer (8PFT) NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 189 Figure 2-94 MDF Cross Connection for PFT (8PFT) (2 of 2) 3LTC0 CONNECTOR 2 PFT1 CONNECTOR 24 49 E 25 50–27V49 E 24 50–27V 25 PFT1 (J) 26 Sta. T0 1 Sta. R0 27 8LC. T0 2 8LC. R0 28 C.O. T0 3 C.O. R0 29 8COT. T0 4 8COT. R0 1 Sta. R0 26 Sta. T0 2 8LC. R0 27 8LC. T0 3 C.O. R0 28 C.O. T0 4 8COT. R0 29 8COT. T0 PFT0 (P) TO S TAT IO N TO P N - 8 L C TO C.O. L IN E TO P N - 8 C...
Page 216
CHAPTER 2 INSTALLATION Alarm Display Panel (MP) NEAX2000 IVS2 Installation Procedure ManualPage 190ND-70928 (E), Issue 1.0 Alarm Display Panel (MP) Figure 2-95 MDF Cross Connection for Alarm Display Panel REAR ALARM DISPLAY PANEL 26 1 50 MN 25 MJ LT C 0 ( J ) 126 25 MJ 50 MN LT C 0 ( P ) PWRMJMIN FRONT25 5025 50MJ MN –27V GPN-CP14PIM0 MDF LT C 0 P J PZ-PW121
Page 217
CHAPTER 2 INSTALLATION Built-in SMDR (MP) NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 191 Built-in SMDR (MP) The MP card provides a RS-232C interface port for SMDR connection. No.0 Port : Async.: 1200/2400/4800/9600/19200 bps Direct connection Connect the SMDR terminal to the RS 0 Port of the PN-CP14 card using the RS RVS-15 (S) CA-A/RS RVS-4 (S) CA-A/RS RVS-4 (S) CA-C as shown below. Figure 2-96 SMDR Terminal Direct Connection Connection via MODEM When the cable length...
Page 218
CHAPTER 2 INSTALLATION Built-in SMDR (MP) NEAX2000 IVS2 Installation Procedure ManualPage 192ND-70928 (E), Issue 1.0 Figure 2-98 RS RVS-15 CA-A/RS RVS-15S CA-A/ RS RVS-4 CA-A/RS RVS-4 CA-C/ RS RVS-4S CA-A/RS RVS-4S CA-C NOTE: If the SMDR terminal does not send DTR or RTS signal, cut the signal lead marked by X in the D-Sub connector (SMDR terminal side) as shown in the wiring diagram above. See Table 2-7. 05A-TXD 05B-GND 06A-TXC (2) 06A-TXC (2) 06B-RXC 06D-TXC (1) 04B-RXD 04A-RTS 03-RXD 01-GND 06-DSR...
Page 219
CHAPTER 2 INSTALLATION Built-in SMDR (MP) NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 193 Figure 2-99 RS NORM-4 CA-A/RS NORM-4S CA-A See Table 2-7. 05A-TXD 05B-GND 0 5C-DTR 06A-TXC (2) 06B-RXC 06D-TXC (1) 04B-RXD 04A-RTS 02-TXD 01-GND 20-DTR 15-TXC (2) 17-RXC 03-RXD 04-RTS 24-TXC (1) 02B-GND 03A-DSR 03B-CTS 02A-DCD 01C-LALB 07-GND 06-DSR 05-CTS 08-DCD 18-LALB DC B A 06 TXC (1) X RXC TXC (2) 05 X DTR GND TXD 04 (RT) X RXD RTS 03 X (ST) CTS DSR 02 ---- X GND DCD 01 X LALB X G...
Page 220
CHAPTER 2 INSTALLATION SMDR/PMS/MCI/CIS Printer/Hotel Printer (AP00) NEAX2000 IVS2 Installation Procedure ManualPage 194ND-70928 (E), Issue 1.0 SMDR/PMS/MCI/CIS Printer/Hotel Printer (AP00) The PN-AP00-B card provides 4 RS-232C interface ports for SMDR, PMS, MCI, CIS Printer, Ho- tel Printer. (1) SMDR/PMS/MCI (VMS) Direct Connection Connect the terminal to the RS0-RS3 port of the PN-AP00-B card using the RS RVS-15 (S) CA-A/RS RVS-4 (S) CA-A/RS RVS-4 (S) CA-C as shown below. See also Figure 2-98....