CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
Application Processor Card
NEAX2000 IVS2 Installation Procedure Manual
ND-70928 (E), Issue 1.0Page 225
PN-4RSTB (MFR) X X XPage 300
PN-4RSTC (CIR) X XPage 302
PN-SC00 (CCH) X XPage 304
PN-SC01 (DCH) X XPage 307
PN-SC03 (ICH) X XPage 310
PN-SC03-A (CSH) X XPage 312
PZ-M537
(EXPMEM)–X–Page 314
PZ-M542 (CONN)–XXPage 317
PZ-M557 (CONN)–XXPage 319
Table 3-2  List of Application Processor Cards (Continued)
NAME
(FUNCTIONAL
NAME)LAMP
X: PROVIDED
–:NOT...

Page 252

CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PN-AP00-A (DBM)
NEAX2000 IVS2 Installation Procedure ManualPage 226ND-70928 (E), Issue 1.0
PN-AP00-A (DBM)
Locations of Lamps, Switches, and Connectors
RS3
RS2
RS1
RS0
SENSE
RUN
MB
SW0
WE 
L3 
L2 
L1 
L0 SW1
J16 

Page 253

CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PN-AP00-A (DBM)
NEAX2000 IVS2 Installation Procedure Manual
ND-70928 (E), Issue 1.0Page 227
Lamp Indications
Switch Settings
LAMP 
NAMECOLOR FUNCTION
RUN Green Flashes at 120 IPM while this card is operating normally.
WE Red Not used
L0-L3 Green Second data setting value for CMD001 > 250
0 1 (Port 0)-3 (Port 2)
L3 Indication of transmitting 
status of Por t 0Indication of CTS signal status on 
Po r t  0 - 2
L2 Indication of transmitting 
status of Por t...

Page 254

CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PN-AP00-A (DBM)
NEAX2000 IVS2 Installation Procedure ManualPage 228ND-70928 (E), Issue 1.0
The figure in the SWITCH NAME column and the position in    in the SETTING POSITION
column indicate the standard setting of the switch. When the switch is not set as shown by the
figure and   , the setting of the switch varies with the system concerned.
NOTE 1:
Set the groove on the switch to the desired position.
NOTE 2:
When the power is on, flip the MB switch to ON...

Page 255

CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PN-AP00-B (AP00)
NEAX2000 IVS2 Installation Procedure Manual
ND-70928 (E), Issue 1.0Page 229
PN-AP00-B (AP00)
Locations of Lamps, Switches, and Connectors
CONN: To CONNR connector on PZ-M537 (EXPMEM)
RS3
RS2
RS1
RS0
SENSE
RUN
MB
SW0 SW2
L3 
L2 
L1 
L0 SW1 CONN
JP0
JP1 

Page 256

CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PN-AP00-B (AP00)
NEAX2000 IVS2 Installation Procedure ManualPage 230ND-70928 (E), Issue 1.0
Lamp Indications
Switch Settings
LAMP 
NAMECOLOR FUNCTION
RUN Green Flashes at 120 IPM while this card is operating normally.
L0-L3 Green Second data setting value for CMD001 > 250
0 1 (Por t 0)-3 (Por t 2)
L3 Indication of transmitting 
status of Por t 0Indication of CTS signal status on
Po r t  0 - 2
L2 Indication of transmitting 
status of Por t 1Indication of DCD...

Page 257

CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PN-AP00-B (AP00)
NEAX2000 IVS2 Installation Procedure Manual
ND-70928 (E), Issue 1.0Page 231
SW0 (DIP SW)
1-3ON Not used
For normal operation
4, 5For normal operation
OFF Not used
6
NOTE 3ONSets No. 0 Port forcibly in a state 
which DSR signal is always pro-
vided.
OFFReceives DSR signal from the DCE 
on No. 0 Port.
7
NOTE 3ONSets No. 1 Port forcibly in a state 
which DSR signal is always provided.
OFFReceives DSR signal from the DCE 
on No. 1 Port.
8
NOTE...

Page 258

CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PN-AP00-B (AP00)
NEAX2000 IVS2 Installation Procedure ManualPage 232ND-70928 (E), Issue 1.0
SW2 (DIP SW)
1
NOTE 3ONSets No. 3 Port forcibly in a state 
which DSR signal is always pro-
vided.
OFFReceives DSR signal from the DCE 
on No. 3 Port.
2ONEnables the receive clock from the 
DCE (Modem) when No. 1 Port is 
synchronous. (Clock is received at 
the RXC terminal)
OFFUses internal clock as the receive 
clock when No. 1 Port is synchro-
nous.
When No. 1...

Page 259

CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PN-AP00-B (AP00)
NEAX2000 IVS2 Installation Procedure Manual
ND-70928 (E), Issue 1.0Page 233
The figure in the SWITCH NAME column and the position in    in the SETTING POSITION
column indicate the standard setting of the switch. When the switch is not set as shown by the
figure and   , the setting of the switch varies with the system concerned.
NOTE 1:
Set the groove on the switch to the desired position.
NOTE 2:
When the power is on, flip the MB switch to...

Page 260

CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PN-AP00-B (AP00)
NEAX2000 IVS2 Installation Procedure ManualPage 234ND-70928 (E), Issue 1.0
ory buffer on the AP00 card even if the cable is disconnected from the DCE.
When the switch is set to OFF, the call records or system messages will be stored
when the cable is disconnected, and will be sent when the cable is re-connected.
NOTE 4:
The use of the external clock (from the distant end) or the internal clock is determined
by the following table:
CLOCKSW2...