CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PN-8DLCP (DLC)
NEAX2000 IVS2 Installation Procedure Manual
ND-70928 (E), Issue 1.0Page 355
PN-8DLCP (DLC)
Locations of Lamps, Switches, and Connectors
Lamp Indications
Switch Settings
This card has no switches.
LAMP 
NAMECOLOR FUNCTION
BL0-7 RedRemains lit when the corresponding circuit is in use.
Flashes at 60 IPM when the corresponding circuit is in make-
busy state or the system data for this card is not assigned.
BL7
BL6
BL5
BL4
BL3
BL2
BL1
BL0 

Page 382

CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PN-2DPCB (DPC)
NEAX2000 IVS2 Installation Procedure ManualPage 356ND-70928 (E), Issue 1.0
PN-2DPCB (DPC)
Location of Lamps, Switches, and Connectors
SW0
XCN1
XCN0
RS1
RS0BL1
LB11
LB12 RSC1
SDT1
RDR1
CDI1
RSC0
SDT0
RDR0
CDI0BL0
LB01
LB02
SW1
To X.21 DTE/DCE 
or PN-M03
To V.24/V.28 DTE/DCE 

Page 383

CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PN-2DPCB (DPC)
NEAX2000 IVS2 Installation Procedure Manual
ND-70928 (E), Issue 1.0Page 357
Lamp Indications
LAMP 
NAMECOLOR FUNCTION
BL0 Red No. 0 
CircuitON:  Ready for digital data transmission or the cir-
cuit is busy.
OFF: Fixed path is not connected.
Flash (60 IPM):  Make-busy state or the system 
data for this card is not assigned.
Flash (120 IPM): Fixed path is connected.
LB01 Red ON:  Loop Back 1 is set.
OFF: Normally operating.
LB02 Red ON:  Loop...

Page 384

CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PN-2DPCB (DPC)
NEAX2000 IVS2 Installation Procedure ManualPage 358ND-70928 (E), Issue 1.0
Switch SettingsBL1 Red No. 1
CircuitON:  Ready for digital data transmission or the cir-
cuit is busy.
OFF: Fixed path is not connected.
Flash (60 IPM):  Make-busy state or the system 
data for this card is not assigned.
Flash (120 IPM): Fixed path is connected.
LB11 Red ON:  Loop Back 1 is set.
OFF: Normally operating.
LB12 Red ON:  Loop Back 2 is set.
OFF: Normally...

Page 385

CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PN-2DPCB (DPC)
NEAX2000 IVS2 Installation Procedure Manual
ND-70928 (E), Issue 1.0Page 359
The figure in the SWITCH NAME column and the position in in the SETTING POSITION
column indicate the standard setting of the switch. When the switch is not set as shown by the
figure and , the setting of the switch varies with the system concerned.
NOTE:
When the power is on, disconnect the cables before unplugging the circuit card and
connect the cables after plugging...

Page 386

CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PN-2ILCA (ILC)
NEAX2000 IVS2 Installation Procedure ManualPage 360ND-70928 (E), Issue 1.0
PN-2ILCA (ILC)
Locations of Lamps, Switches, and Connectors
PA L 1AC T1
LPB1
B21
B11
PA L 0 AC T0
LPB0
B20
B10
SW1
SW0 

Page 387

CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PN-2ILCA (ILC)
NEAX2000 IVS2 Installation Procedure Manual
ND-70928 (E), Issue 1.0Page 361
Lamp Indications
LAMP 
NAMECOLOR FUNCTION
ACT1 Green No.1 
CircuitON: Normally operating.
OFF: Not operating.
PAL1 Red ON:  Line is short-circuiting.
OFF: Normally operating.
LPB1 Red OFF: Not used.
B21 Green ON: B2 channel is in use.
OFF: B2 channel is idle.
B11 Green ON: B1 channel is in use.
OFF: B1 channel is idle.
ACT0 Green No. 0 
CircuitON: Normally operating....

Page 388

CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PN-2ILCA (ILC)
NEAX2000 IVS2 Installation Procedure ManualPage 362ND-70928 (E), Issue 1.0
Switch Settings
The figure in the SWITCH NAME column and the position in in the SETTING POSITION
column indicate the standard setting of the switch. When the switch is not set as shown by the
figure and , the setting of the switch varies with the system concerned.
SWITCH NAMESWITCH 
NUMBERSETTING
POSITIONFUNCTION CHECK
SW1
(Piano Key SW)1 Always set to OFF
2 Always set...

Page 389

CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PN-4LCC (LC)
NEAX2000 IVS2 Installation Procedure Manual
ND-70928 (E), Issue 1.0Page 363
PN-4LCC (LC)
Locations of Lamps, Switches, and Connectors
Lamp Indications
Switch Settings
This card has no switches.
LAMP 
NAMECOLOR FUNCTION
BL0-3 RedRemains lit when the corresponding circuit is in use.
Flashes at 60 IPM when the corresponding circuit is in make-
busy state or the system data for this card is not assigned.
BL3
BL2
BL1
BL0 

Page 390

CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PN-4LCD-A (LC)
NEAX2000 IVS2 Installation Procedure ManualPage 364ND-70928 (E), Issue 1.0
PN-4LCD-A (LC)
Locations of Lamps, Switches, and Connectors
Lamp Indications
Switch Settings
This card has no switches.
LAMP 
NAMECOLOR FUNCTION
BL0-3 RedRemains lit when the corresponding circuit is in use.
Flashes at 60 IPM when the corresponding circuit is in make-
busy state or the system data for this card is not assigned.
BL3
BL2
BL1
BL0 