Page 91

CHAPTER 2 INSTALLATION
Floor Standing Installation
NEAX2000 IVS2 Installation Procedure Manual
ND-70928 (E), Issue 1.0Page 65
Placing PIM on BASE TRAY for Stationary Equipment
Place the PIM and the BASE on the BASE TRAY.
Figure 2-14  Placing PIM on BASE TRAY
BASE TRAY 

Page 92

CHAPTER 2 INSTALLATION
Floor Standing Installation
NEAX2000 IVS2 Installation Procedure ManualPage 66ND-70928 (E), Issue 1.0
Connection of PIMs
NOTE:
The FRONT STOPPER, BUILD PLATES, and screws are attached to the PIM.
(1) Insert the BUILD PLATES (R)/(L) into the slits of the SIDE FRAME, then slide them 
backward and lock them.
(2) Place the FRONT STOPPER on the PIM, then secure it with three screws.
Figure 2-15  Connection of BUILD PLATE
BUILD PLATE (L) BUILD PLATE (R)
SIDE FRAME 

Page 93

CHAPTER 2 INSTALLATION
Floor Standing Installation
NEAX2000 IVS2 Installation Procedure Manual
ND-70928 (E), Issue 1.0Page 67
Figure 2-16  Connection of FRONT STOPPER
SCREWPIM SIDE FRAME
SCREWSCREWPZ-PW121PIM TOP FRAME
FRONT 
STOPPER
SCREWS
FRONT STOPPER 

Page 94

CHAPTER 2 INSTALLATION
Floor Standing Installation
NEAX2000 IVS2 Installation Procedure ManualPage 68ND-70928 (E), Issue 1.0
(3) Hook the PIM onto the BUILD PLATE’s hooks.
(4) Slide the PIM backward until it comes to the back end.
(5) Secure the PIM with three screws.
Figure 2-17  Connection of Modules
SCREWS 

Page 95

CHAPTER 2 INSTALLATION
Floor Standing Installation
NEAX2000 IVS2 Installation Procedure Manual
ND-70928 (E), Issue 1.0Page 69
Installation of I/F BRACKET
Install the I/F BRACKET to the top-stack PIMs if the equipment is stacked with four or more 
PIMs.
Secure the I/F BRACKET to rear side of top-stack PIMs with two screws from inside of PIMs.
NOTE:
Screws are attached to the I/F BRACKET.
SCREW FRONT SIDE
SCREW
I/F BRACKET 

Page 96

CHAPTER 2 INSTALLATION
Floor Standing Installation
NEAX2000 IVS2 Installation Procedure ManualPage 70ND-70928 (E), Issue 1.0
Installation of TOP COVER
(1) Hang four hooks of the TOP COVER on the back board of PIM as shown below.
(2) Secure the TOP COVER to the front side of the PIM with two screws.
NOTE:
Screws are attached to BASE/TOP ASSEM.
HOOK 

Page 97

CHAPTER 2 INSTALLATION
Floor Standing Installation
NEAX2000 IVS2 Installation Procedure Manual
ND-70928 (E), Issue 1.0Page 71
Installation of MOUNTING BRACKET
Install the MOUNTING BRACKET to the top-stack PIM if the equipment is stacked with four 
or more PIMs.
(1) Remove four screws located on the rear side of the top-stack PIM.
(2) Secure the MOUNTING BRACKET to the PIM with the removed screws.
(3) Secure the PIM to the wall or ceiling by using wires, chains and eyebolts (locally 
provided).
Figure...

Page 98

CHAPTER 2 INSTALLATION
Wall Mounting Installation
NEAX2000 IVS2 Installation Procedure ManualPage 72ND-70928 (E), Issue 1.0
Wall Mounting Installation
Check the site for installing the PBX with the work drawing to verify that 
the required floor space is ensured and that service entrances and ducts 
for trunk/extension cables, power cables and grounding conductors 
have been properly worked at correct positions.
See Figure 2-7 and Figure 2-8.
Detach the front cover of each PIM. See “Detaching FRONT...

Page 99

CHAPTER 2 INSTALLATION
Wall Mounting Installation
NEAX2000 IVS2 Installation Procedure Manual
ND-70928 (E), Issue 1.0Page 73
Figure 2-19  Wall Marking for HANGER ASSEM
352
(13.9) 356.5
(14.0)210.8
(8.3)
HANGER ASSEM
ANCHOR/ 
SCREW
(x 3/PIM)
BASE167.5
(7.0)167.5 UNIT : mm (inch)
(7.0)
352
(13.9)
352
(13.9)
352
(13.9)
210.8
(8.3)
210.8
(8.3)
210.8
(8.3)
210.8
(8.3) 

Page 100

CHAPTER 2 INSTALLATION
Wall Mounting Installation
NEAX2000 IVS2 Installation Procedure ManualPage 74ND-70928 (E), Issue 1.0
Hanging PIM to HANGER ASSEM
(1) Secure the HANGER ASSEM to the surface of a wall with three screws.
Select screws to match with the wall type as follows.
A concrete wall is recommended because it is the most firm to mount the PBX of the 
three. The plaster board is the least firm wall of the three.
(2) Hang the slits of the rear of a PIM to the hooks of the HANGER ASSEM.
(3) Secure...
Start reading NEC Neax 2000 Ivs2 Installation Procedure Manual