Page 121
CHAPTER 2 INSTALLATION Battery Connection NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 95 C AU TIO N 3. Battery Replacement Table and Battery Warnings The label which shows battery replacement table and battery warnings is attached to the reverse side of Front Cover for PIM and BATTM. During the battery installation process, the warning statements must be observed. When re- placing batteries, the battery replacement table should be observed in order to increase bat- tery...
Page 122
CHAPTER 2 INSTALLATION Internal Battery Connection NEAX2000 IVS2 Installation Procedure ManualPage 96ND-70928 (E), Issue 1.0 Internal Battery Connection (1) Connect the BATT CA INT cable to the batteries as shown below. (2) Mount the battery unit (24V DC, 3.2-3.4AH) into the PIM. (3) Plug the BATT CA INT connector into the BATT1 connector on the PZ-PW121 card. (4) Secure the batteries and battery cable using tie wraps. Figure 2-37 Internal Battery Mounting (1 of 2) 67 mmDIMENSION OF BATTERY(2.6 inch)...
Page 123
CHAPTER 2 INSTALLATION Internal Battery Connection NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 97 Figure 2-37 Internal Battery Mounting (2 of 2) TIE WRAP + + – –
Page 124
CHAPTER 2 INSTALLATION Internal Battery Connection NEAX2000 IVS2 Installation Procedure ManualPage 98ND-70928 (E), Issue 1.0 (5) When the system is configured with two or more PIMs, connect the BATT CA INT and the PWR CA-A as shown below. Figure 2-38 Internal Battery Connection for Multiple-PIM Configuration NOTE 1: One Internal Battery unit (24V DC, 3.2-3.4AH) can be mounted in each PIM. NOTE 2: Internal Batteries are multi-connected for each two PIMs. PIM3PWR PIM2 PIM1PIM7 PIM6 PIM5 PIM4 PIM0 PWR...
Page 125
CHAPTER 2 INSTALLATION External / BATTM Battery Connection NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 99 External / BATTM Battery Connection (1) Connect the BATT CA EXT cable to the batteries as shown below. (2) Mount the battery units (24V DC, 24AH per unit) into the Battery Module (BATTM), if the BATTM required. (3) Plug the BATT CA EXT connector into the BATT1 connector on the PZ-PW121 card in PIM0 or PIM4. NOTE:Screws are attached to the BATTM. Figure 2-39 Battery...
Page 126
CHAPTER 2 INSTALLATION External / BATTM Battery Connection NEAX2000 IVS2 Installation Procedure ManualPage 100ND-70928 (E), Issue 1.0 Figure 2-40 Battery Mounted into BATTM BATTM FRONT TO BATT1 CONNECTOR ON PZ-PW121 IN PIM0/PIM4
Page 127
CHAPTER 2 INSTALLATION External / BATTM Battery Connection NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 101 (3) When the system is configured with two or more PIMs, connect the BATT CA EXT and the PWR CA-A as shown below. Figure 2-41 External/BATTM Battery Connection for Multiple-PIM Configuration NOTE 1: One pair each of battery unit (24V DC, 24AH) can be housed in a BATTM, for each two PIMs. NOTE 2: External Batteries are multi-connected for each four PIMs. PWR BATT CA...
Page 128
CHAPTER 2 INSTALLATION Cable Running to MDF NEAX2000 IVS2 Installation Procedure ManualPage 102ND-70928 (E), Issue 1.0 CABLE RUNNING TO MDF Installation of External MDF Secure the external MDF onto the floor or the wall. Mount the required MDF components. If required, install the cable ducts for the cables to be laid between the MDF and the Main Equipment. In this case, confirm the locations of the cable holes for the Main Equipment. Figure 2-42 MDF Cable Hole Location BASE MODULE : CABLE HOLE FRONT
Page 129
CHAPTER 2 INSTALLATION MDF Cable NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 103 MDF Cable To facilitate the termination of the 25 pair cables (MDF cables) from the system to the MDF shown in Figure 2-43, the length of each cable to be used should be predetermined according to the distance between the MDF and the system. Each cable should be labeled at both ends using a cable number or cable designation as shown in Table 2-2. Figure 2-43 MDF Cable TO P I MCHAMP CONNECTOR...
Page 130
CHAPTER 2 INSTALLATION MDF Cable NEAX2000 IVS2 Installation Procedure ManualPage 104ND-70928 (E), Issue 1.0 Table 2-2 MDF Cables for each PIM FROM CABLE NUMBERTOCABLE DESIGNATION MODULE CONNECTION PIM 0 LTC0 1 MDF 0 LTC0 LT C 1 2 0 LT C 1 LT C 2 3 0 LT C 2 LT C 3 4 0 LT C 3 PIM 1 LTC0 5 MDF 1 LTC0 LT C 1 6 1 LT C 1 LT C 2 7 1 LT C 2 LT C 3 8 1 LT C 3 PIM 2 LTC0 9 MDF 2 LTC0 LT C 1 1 0 2 LT C 1 LT C 2 1 1 2 LT C 2 LT C 3 1 2 2 LT C 3 PIM 3 LTC0 13 MDF 3 LTC0 LT C 1 1...