Page 141
CHAPTER 2 INSTALLATION LTC Connector Pin Arrangement NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 115 PIM1 (LTC0 - LTC3) LTC Connector Pin Arrangement *In Slot 08-11, only 4-port line/trunk cards are mountable. When 8-port cards are mounted in Slot 04-07, only application processor cards are mountable in Slot 08-11. LT C 0 1 26 LEN100 LT00/AP00 2 27 101 3 28 102 4 29 103 5 30 104 6 31 105 7 32 106 8 33 107 9 34 108 LT01/AP01 10 35 109 11 36 110 12 37 111 13 38 112 14 39 113...
Page 142
CHAPTER 2 INSTALLATION LTC Connector Pin Arrangement NEAX2000 IVS2 Installation Procedure ManualPage 116ND-70928 (E), Issue 1.0 PIM2 (LTC0 - LTC3) LTC Connector Pin Arrangement *In Slot 08-11, only 4-port line/trunk cards are mountable. When 8-port cards are mounted in Slot 04-07, only application processor cards are mountable in Slot 08-11. LT C 0 1 26 LEN200 LT00/AP00 2 27 201 3 28 202 4 29 203 5 30 204 6 31 205 7 32 206 8 33 207 9 34 208 LT01/AP01 10 35 209 11 36 210 12 37 211 13 38 212 14 39 213 15...
Page 143
CHAPTER 2 INSTALLATION LTC Connector Pin Arrangement NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 117 PIM3 (LTC0 - LTC3) LTC Connector Pin Arrangement *In Slot 08-11, only 4-port line/trunk cards are mountable. When 8-port cards are mounted in Slot 04-07, only application processor cards are mountable in Slot 08-11. LT C 0 1 26 LEN300 LT00/AP00 2 27 301 3 28 302 4 29 303 5 30 304 6 31 305 7 32 306 8 33 307 9 34 308 LT01/AP01 10 35 309 11 36 310 12 37 311 13 38 312 14 39 313...
Page 144
CHAPTER 2 INSTALLATION LTC Connector Pin Arrangement NEAX2000 IVS2 Installation Procedure ManualPage 118ND-70928 (E), Issue 1.0 PIM4 (LTC0 - LTC3) LTC Connector Pin Arrangement *In Slot 08-11, only 4-port line/trunk cards are mountable. When 8-port cards are mounted in Slot 04-07, only application processor cards are mountable in Slot 08-11. LT C 0 1 26 LEN400 LT00/AP00 2 27 401 3 28 402 4 29 403 5 30 404 6 31 405 7 32 406 8 33 407 9 34 408 LT01/AP01 10 35 409 11 36 410 12 37 411 13 38 412 14 39 413 15...
Page 145
CHAPTER 2 INSTALLATION LTC Connector Pin Arrangement NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 119 PIM5 (LTC0 - LTC3) LTC Connector Pin Arrangement *In Slot 08-11, only 4-port line/trunk cards are mountable. When 8-port cards are mounted in Slot 04-07, only application processor cards are mountable in Slot 08-11. LT C 0 1 26 LEN500 LT00/AP00 2 27 501 3 28 502 4 29 503 5 30 504 6 31 505 7 32 506 8 33 507 9 34 508 LT01/AP01 10 35 509 11 36 510 12 37 511 13 38 512 14 39 513...
Page 146
CHAPTER 2 INSTALLATION LTC Connector Pin Arrangement NEAX2000 IVS2 Installation Procedure ManualPage 120ND-70928 (E), Issue 1.0 PIM6 (LTC0 - LTC3) LTC Connector Pin Arrangement *In Slot 08-11, only 4-port line/trunk cards are mountable. When 8-port cards are mounted in Slot 04-07, only application processor cards are mountable in Slot 08-11. LT C 0 1 26 LEN600 LT00/AP00 2 27 601 3 28 602 4 29 603 5 30 604 6 31 605 7 32 606 8 33 607 9 34 608 LT01/AP01 10 35 609 11 36 610 12 37 611 13 38 612 14 39 613 15...
Page 147
CHAPTER 2 INSTALLATION LTC Connector Pin Arrangement NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 121 PIM7 (LTC0 - LTC3) LTC Connector Pin Arrangement *In Slot 08-11, only 4-port line/trunk cards are mountable. When 8-port cards are mounted in Slot 04-07, only application processor cards are mountable in Slot 08-11. LT C 0 1 26 LEN700 LT00/AP00 2 27 701 3 28 702 4 29 703 5 30 704 6 31 705 7 32 706 8 33 707 9 34 708 LT01/AP01 10 35 709 11 36 710 12 37 711 13 38 712 14 39 713...
Page 148
CHAPTER 2 INSTALLATION MDF Cross Connections NEAX2000 IVS2 Installation Procedure ManualPage 122ND-70928 (E), Issue 1.0 MDF Cross Connections This table shows the cross connections on the MDF for LTC0 - LTC3. Table 2-4 LTC0 - LTC3 MDF Cross Connection PINRUNNING CABLESTATION CABLESLOTSTYPE OF INTERFACE CO LDT2-W E&M 4-W E&M DID SLT 8COT 4COT 2LDT 2ODT 2ODT AUC 4DIT 8LC 4LC AUC 26 WH-BL GN 1T0 T0 T0 T0 TxT0 T0 T0 T0 T0 T0 1 BL-WH RD R0 R0 R0 R0 TxR0 R0 R0 R0 R0 R0 27 WH-OR BK T1 T1 T1 RcvT0T1 T1 T1 T1...
Page 149
CHAPTER 2 INSTALLATION MDF Cross Connections NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 123 34 RD-BR GN 2T0 T0 T0 T0 TxT0 T0 T0 T0 T0 T0 9 BR-RD RD R0 R0 R0 R0 TxR0 R0 R0 R0 R0 R0 35RD-SL BK T1T1T1T1 RcvT0T1 T1 T1 T1 T1 10SL-RD YL R1R1R1R1 RcvR0R1 R1 R1 R1 R1 36BK-BL GN T2 T2 TxT1 T2T2T2 11 BL-BK RD R2 R2 TxR1 R2 R2 R2 37 BK-OR BK T3 T3 RcvT1T3 T3 T3 12 OR-BK YL R3 R3 RcvR1R3 R3 R3 38 BK-GN GN T4 T4 13 GN-BK RD R4 R4 39 BK-BR BK T5 T5 14 BR-BK YL R5 R5 40 BK-SL GN T6 T6 15...
Page 150
CHAPTER 2 INSTALLATION MDF Cross Connections NEAX2000 IVS2 Installation Procedure ManualPage 124ND-70928 (E), Issue 1.0 42 YL-OR GN 3T0 T0 T0 T0 TxT0 T0 T0 T0 T0 T0 17OR-YL RD R0R0R0R0TxR0R0R0R0R0R0 43 YL-GN BK T1 T1 T1 RcvT0T1 T1 T1 T1 T1 18GN-YL YL R1R1R1 RcvR0R1 R1 R1 R1 R1 44YL-BR GN T2 T2 T1TxT1 T2T2T2 19 BR-YL RD R2 R2 R1 TxR1 R2 R2 R2 45 YL-SL BK T3 T3 RcvT1T3 T3 T3 20 SL-YL YL R3 R3 RcvR1R3 R3 R3 46 VI-BL GN T4 T4 21 BL-VI RD R4 R4 47 VI-OR BK T5 T5 22 OR-VI YL R5 R5 48 VI-GN GN T6 T6 23 GN-VI RD...