Page 111

CHAPTER 2 INSTALLATION
Connection of DC Power Cable
NEAX2000 IVS2 Installation Procedure Manual
ND-70928 (E), Issue 1.0Page 85
Connection of DC Power Cable
(1) Confirm the connection of power output cables, as shown below (These cables are pre-
installed).
(2) For PIM0, connect the PWR CNT CA-E to the CN103 connector on the PZ-PW121 card and 
the PWR1 connector on the BWB.
For PIM1 to PIM7, connect the PWR CNT CA-D to the CN103 connector on the PZ-PW121 
card and the PWR1 connector on the BWB.
Figure...

Page 112

CHAPTER 2 INSTALLATION
Connection of DC Power Cable
NEAX2000 IVS2 Installation Procedure ManualPage 86ND-70928 (E), Issue 1.0
(3) When you need a –48V DC power supply installed for a Cell Station (Zone Transceiver) in 
WCS system, do the following procedure. If not, skip this procedure and go to item (4) on 
Page 88
.
STEP 1: Attach four screws preliminary to the PZ-PW122 card.
STEP 2: Mount the PZ-PW122 card into the PIM which accommodates the CSI cards, and fas-
ten the screws.
NOTE:
Screws are...

Page 113

CHAPTER 2 INSTALLATION
Connection of DC Power Cable
NEAX2000 IVS2 Installation Procedure Manual
ND-70928 (E), Issue 1.0Page 87
STEP 3:  Connect the PWR CNT CA-E or PWR CNT CA-D, and POWER OUTPUT CABLE 
(–48V, E) as shown below.
Figure 2-32  Cable Connection between PZ-PW121/PZ-PW122 and BWB
PWR CNT CA-E  (FOR PIM0) 
PWR CNT CA-D (FOR PIM1 TO PIM7)PWR0B PWR1 PZ-PW121 BWB (BACK WIRING BOARD)PIM
PWR0CPWR0A
POWER OUTPUT CABLE (+90V, CR, E) PZ-PW122
POWER OUTPUT CABLE (+5V, -27V, E)
POWER OUTPUT CABLE (-48V,...

Page 114

CHAPTER 2 INSTALLATION
Connection of DC Power Cable
NEAX2000 IVS2 Installation Procedure ManualPage 88ND-70928 (E), Issue 1.0
(4) When the system is configured with two or more PIMs, connect the PZ-PW121 cards to 
each other using the PWR CA-A for power multi-connection.
Figure 2-33  PWR CA-A
Figure 2-34  Connection of PWR CA-A Cables
(a) When using an Internal Battery
550 mm (21. 7inch)
PWR CA-A
PIM3
TO INTERNAL 
BATTERY PWR
PWR 
CA-A
PIM2
PIM1PIM7
PIM6
PIM5
PIM4 PIM0
TO INTERNAL 
BATTERY PWR
TO...

Page 115

CHAPTER 2 INSTALLATION
Connection of DC Power Cable
NEAX2000 IVS2 Installation Procedure Manual
ND-70928 (E), Issue 1.0Page 89
Figure 2-35  Connection of PWR CA-A Cables
(b) When using an External Battery
PIM 3PWR
PIM 2
PIM 1PIM 7
PIM 6
PIM 5
PIM 4 PIM 0
PWR
PWRPWR 
CA-A
PWR
PWR
PWR
PWR
PWR
PWR 
CA-A
TO EXTERNAL BATTERY 

Page 116

CHAPTER 2 INSTALLATION
Supply Voltage Check And Heat Run Test
NEAX2000 IVS2 Installation Procedure ManualPage 90ND-70928 (E), Issue 1.0
SUPPLY VOLTAGE CHECK AND HEAT RUN TEST
Precautions
(1) Check the switch position of each PZ-PW121 card before turning power on.
Make sure that the AC120V/240V selector switch is positioned to appropriate voltage for 
each country (AC120V or AC240V).
Make sure that the battery mode selector switch is positioned as shown below to meet the 
kind of battery:
(2) When the...

Page 117

CHAPTER 2 INSTALLATION
Power Routing
NEAX2000 IVS2 Installation Procedure Manual
ND-70928 (E), Issue 1.0Page 91
Power Routing
NOTE 1:PN-4LCD/4LCF/4LCL/4LCW card provides +80V on-board power supply (+80VOBP).
NOTE 2:PN-AUCA, PN-2DLCB/PN-2DLCN, PN-2DLCC, PN-2LDTA, PN-2ODTA/2ODTB card
provides –48V on-board power supply (–48VOBP).
+5V
-27V
Ð27V
CR
+90V
+90V AC
AC PZ-PW121
+5V
-5V
-5V +5V
+80V
-27V-27V
-27V
CR
CR
PZ-PW121
NOTE 1
+80VOBP
+5V
-48V
-27V
CR-48VOBP
NOTE 2
BATTERY PWR CA-A
AC CORD-B
TERMINAL...

Page 118

CHAPTER 2 INSTALLATION
Checking for Supply Voltage
NEAX2000 IVS2 Installation Procedure ManualPage 92ND-70928 (E), Issue 1.0
Checking for Supply Voltage
Heat Run Test
Turn the SW1 switch ON. Keep it on for 5 minutes to check for no abnormal voltage. After com-
pleting the test, turn OFF the SW1 switch of the PZ-PW121 card on PIM0. Then, turn OFF the
SW1 switches of all the PZ-PW121 cards.
Before connecting AC Cord, verify:
- that the SW1 switch of the PZ-PW121 card is positioned to OFF;
- that the AC...

Page 119

CHAPTER 2 INSTALLATION
Heat Run Test
NEAX2000 IVS2 Installation Procedure Manual
ND-70928 (E), Issue 1.0Page 93
Figure 2-36  Confirming Output Voltage
TESTER
DC100V
MJ
MN
ON
-27V
FG
GND
I O
SW1
TO         FRAME GROUND 
TERMINAL IN PIM
TO TERMINAL 
BLOCK ON BASE 

Page 120

CHAPTER 2 INSTALLATION
Battery Connection
NEAX2000 IVS2 Installation Procedure ManualPage 94ND-70928 (E), Issue 1.0
BATTERY CONNECTION
WAR NIN G
TURN OFF AC POWER BEFORE CONNECTING BATTERIES.
CAU TIO N
1. 24V batteries must be used in this system. 
2. If battery terminals (+,  –) come in contact with the module while connecting the battery cable
to the PZ-PW121 card, the PZ-PW121 card or the BWB may be broken. Therefore, you must
perform work in accordance with the following steps when mounting or...