Page 131
CHAPTER 2 INSTALLATION MDF Cable NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 105 PIM 6 LTC0 25 MDF 6 LTC0 LT C 1 2 6 6 LT C 1 LT C 2 2 7 6 LT C 2 LT C 3 2 8 6 LT C 3 PIM 7 LTC0 29 MDF 7 LTC0 LT C 1 3 0 7 LT C 1 LT C 2 3 1 7 LT C 2 LT C 3 3 2 7 LT C 3 Table 2-2 MDF Cables for each PIM (Continued) FROM CABLE NUMBERTOCABLE DESIGNATION MODULE CONNECTION
Page 132
CHAPTER 2 INSTALLATION Cable Running to External MDF NEAX2000 IVS2 Installation Procedure ManualPage 106ND-70928 (E), Issue 1.0 Cable Running to External MDF (1) When using the cable hole of the BASE, bring the MDF cable up to the Main Equipment through the cable hole of the BASE. (2) When using the cable hole of the PIM, make the cable hole on the right side of PIM. Then, bring the MDF cable up to PIM 0 through the cable hole of the BASE, and bring the MDF cable up to the other PIM through the cable...
Page 133
CHAPTER 2 INSTALLATION Cable Running to External MDF NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 107 (3) Connect the champ connector of each MDF cable to the LTC connector located on the PIM using the screws provided, as shown below. (4) Secure the MDF cables to the PIM using tie wraps. Figure 2-45 Cable Running to the External MDF (1 of 2) (a) Using cable hole of BASE BATTM PIM2 PIM1 PIM0 FRONT CHAMP CONNECTORLTC CONNECTOR PIM3 TO M D F
Page 134
CHAPTER 2 INSTALLATION Cable Running to External MDF NEAX2000 IVS2 Installation Procedure ManualPage 108ND-70928 (E), Issue 1.0 Figure 2-45 Cable Running to the External MDF (2 of 2) (b) Using cable hole of PIM BATTM PIM 2 PIM 1 PIM 0 FRONT TO M DF TO M DF TO M DF TO M DF CHAMP CONNECTORLTC CONNECTOR PIM 3
Page 135
CHAPTER 2 INSTALLATION Termination Of Cables On MDF NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 109 TERMINATION OF CABLES ON MDF Cable Connection to MDF Connect the cables to the MDF by referring to Figure 2-46 and Table 2-3. Figure 2-46 Card Slots and the LTC Connectors Table 2-3 LTC Connector Accommodation LTC CONNECTOR CARD SLOT NUMBER REMARKS LTC0 LT00 - LT02/AP00 - AP02 LTC1 LT03 - LT05/AP03 - AP05 LTC2 LT06 - LT08/AP06 - AP08 LTC3 LT09 - LT11/AP09 - AP11...
Page 136
CHAPTER 2 INSTALLATION Location of Each LEN NEAX2000 IVS2 Installation Procedure ManualPage 110ND-70928 (E), Issue 1.0 Location of Each LEN This figure shows the relationship between each Line Equipment Number (LEN) and each Card Slot Number (LT Number). LEN 000 - 363 (PIM0 - 3) Page 111 LEN 400 - 763 (PIM4 - 7) Page 112
Page 137
CHAPTER 2 INSTALLATION Location of Each LEN NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 111 LEN 000 - 363 (PIM 0 - 3) Location of each LEN *In Slot 08-11, only 4-port line/trunk cards are mountable. When 8-port cards are mounted in Slot 04-07, only application processor cards are mountable in Slot 08-11. PIM 3 307 306 305 304 303 302 301 300 (LT00) XYY XYY XYY XYY XYY XYY XYY XYY (LTXX) 315 314 313 312 311 310 309 308 (LT01)323 322 321 320 319...
Page 138
CHAPTER 2 INSTALLATION Location of Each LEN NEAX2000 IVS2 Installation Procedure ManualPage 112ND-70928 (E), Issue 1.0 LEN 400 - 763 (PIM 4 - 7) Location of each LEN *In Slot 08-11, only 4-port line/trunk cards are mountable. When 8-port cards are mounted in Slot 04-07, only application processor cards are mountable in Slot 08-11. PIM 7 707 706 705 704 703 702 701 700 (LT00)715 714 713 712 711 710 709 708 (LT01)723 722 721 720 719 718 717 716 (LT02)731 730 729 728 727 726...
Page 139
CHAPTER 2 INSTALLATION LTC Connector Pin Arrangement NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 113 LTC Connector Pin Arrangement This figure shows the LTC Connector Pin Arrangement. PIM0 (LTC0 - LTC3) Page 114 PIM1 (LTC0 - LTC3) Page 115 PIM2 (LTC0 - LTC3) Page 116 PIM3 (LTC0 - LTC3) Page 117 PIM4 (LTC0 - LTC3) Page 118 PIM5 (LTC0 - LTC3) Page 119 PIM6 (LTC0 - LTC3) Page 120 PIM7 (LTC0 - LTC3) Page 121
Page 140
CHAPTER 2 INSTALLATION LTC Connector Pin Arrangement NEAX2000 IVS2 Installation Procedure ManualPage 114ND-70928 (E), Issue 1.0 PIM0 (LTC0 - LTC3) LTC Connector Pin Arrangement *In Slot 08-11, only 4-port line/trunk cards are mountable. When 8-port cards are mounted in Slot 04-07, only application processor cards are mountable in Slot 08-11. LT C 0 1 26 LEN000 LT00/AP00 2 27 001 3 28 002 4 29 003 5 30 004 6 31 005 7 32 006 8 33 007 9 34 008 LT01/AP01 10 35 009 11 36 010 12 37 011 13 38 012 14 39 013 15...