Page 41
CHAPTER 1 GENERAL INFORMATION Control Card NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 15 Control Card This table shows the names and functions of each control card. Table 1-3 Control Card Name and Function EQUIPMENT NAMEFUNCTIONAL NAMEFUNCTION PN-CP14 MP Main Processor Card Provides Memory, TDSW (1024CH x 1024CH), 16-line CFT, PB sender, Clock, PLO 2 ports (receiver mode/source mode), two RS-232C ports, 2-line DAT (Recording duration: Max. 128sec.), DK, 4-line PB...
Page 42
CHAPTER 1 GENERAL INFORMATION Application Processor Card NEAX2000 IVS2 Installation Procedure ManualPage 16ND-70928 (E), Issue 1.0 Application Processor Card This table shows the names and functions of each application processor card. Table 1-4 Application Processor Card Name and Function EQUIPMENT NAMEFUNCTIONAL NAMEFUNCTION PN-AP00-A [For North America/ Latin America Only]DBM Data Base Module Card for WCS Roaming function One card per WCS system. PN-AP00-B AP00 Application Processor Card Provides...
Page 43
CHAPTER 1 GENERAL INFORMATION Application Processor Card NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 17 PN-DAIA DAI Digital Trunk Interface (23B+D, 1.5 Mbps) Card for Remote PIM Accomodates 24-channel PCM digital lines, and provides Firmware Processor and BUS interface. One through three cards, corresponding to the number of remote site, must be provided at main site. PN-DAIB DAI Digital Trunk Interface (23B+D, 1.5 Mbps) Card for Remote PIM Accomodates 24-channel PCM digital...
Page 44
CHAPTER 1 GENERAL INFORMATION Application Processor Card NEAX2000 IVS2 Installation Procedure ManualPage 18ND-70928 (E), Issue 1.0 PN-IPTA IPT IP Trunk Card Accommodates the IP network and transmit/receive com- pressed voice or signals over IP network. Used with max. four PN-4VCTH cards (16 channels). 10 BASE-T/100 BASE-TX twisted pair cable is connected directly to this card. PN-24PRTA PRT ISDN Primary Rate (23B+D) Interface Card Provides a built-in D-channel Handler (DCH). PN-4RSTB MFR 4-line MF...
Page 45
CHAPTER 1 GENERAL INFORMATION Application Processor Card NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 19 PZ-M537 EXPMEM Memory Expansion Card for MP/AP00 Card The system capacity is expanded as follows: When mounted on PN-CP14 (MP) card: When mounted on PN-AP00-B (AP00) card: PZ-M542 [For Other Countries]CONN Coaxial Cable Connection Card Used to connect a coaxial cable for Digital Trunk Interface. Max. two cards can be connected to LTC connector of each PIM. PZ-M557 [For...
Page 46
CHAPTER 1 GENERAL INFORMATION Line/Trunk Card NEAX2000 IVS2 Installation Procedure ManualPage 20ND-70928 (E), Issue 1.0 Line/Trunk Card This table shows the names and functions of each line/trunk card. Table 1-5 Line/Trunk Card Name and Function EQUIPMENT NAMEFUNCTIONAL NAMEFUNCTION PN-2AMPA AMP 2-line Amplifier Trunk Card Provides Echo Canceller (EC), Automatic Gain Controller (AGC) and Tone Disabler (TD) functions. PN-AUCA AUC 2-line Analog Long Line Circuit Card provided with Power Failure Transfer...
Page 47
CHAPTER 1 GENERAL INFORMATION Line/Trunk Card NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 21 PN-4COTE [For Australia]COT 4-line Central Office Trunk Card (Loop Start Trunk) Provides a detector for line fault conditions. PN-4COTG COT 4-line Central Office Trunk Card (Loop Start trunk) Provides loop detection, receiving/sending the Caller ID (CLASS SM) signal. PN-6COTJ [For Australia]COT 6-line Central Office Trunk Card (Loop Start Trunk) Provides a detector for line fault...
Page 48
CHAPTER 1 GENERAL INFORMATION Line/Trunk Card NEAX2000 IVS2 Installation Procedure ManualPage 22ND-70928 (E), Issue 1.0 PN-2DITA [For Hong Kong]DIT 2-line Direct Inward Dialing Trunk Card Provides loop detection, sending reverse signal and PB to DP signal conversion. Equipped with –48V DC-DC on-board power supply. PN-4DITB DIT 4-line Direct Inward Dialing Trunk Card Provides loop detection, sending reverse signal and PB to DP signal conversion. Equipped with –48V DC-DC on-board power supply. PN-DK00 DK...
Page 49
CHAPTER 1 GENERAL INFORMATION Line/Trunk Card NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 23 PN-8DLCP DLC 8-line Digital Line Circuit Card for Dterm75/65 (Series E/III), DSS Console, ATTCON, DESKCON [–27V version, 2-wire type] PN-2DPCB DPC 2-line Data Port Controller Card Used for intra-office or inter-office digital data transmission on nailed down connection. Accommodates max. two DTEs with V.11 (X.21) interface or V.24/V.28 (RS-232C) interface. PN-2ILCA ILC 2-line ISDN Line...
Page 50
CHAPTER 1 GENERAL INFORMATION Line/Trunk Card NEAX2000 IVS2 Installation Procedure ManualPage 24ND-70928 (E), Issue 1.0 PN-4LCL [For China]LC 4-line Analog Line Circuit Card for Single Line Telephones Loop resistance : Max. 600 ohms (including telephone set) Provides Message Waiting Lamp control function for each circuit, and reverse function for only No. 3 circuit. Equipped with +80V DC-DC on-board power supply. PN-4LCV [For Brazil]LC 4-Line Analog Line Circuit Card for Single Line Telephones Loop...