Home > NEC > Communications System > NEC Neax 2000 Ivs2 Installation Procedure Manual

NEC Neax 2000 Ivs2 Installation Procedure Manual

Here you can view all the pages of manual NEC Neax 2000 Ivs2 Installation Procedure Manual. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 51

CHAPTER 1 GENERAL INFORMATION
Line/Trunk Card
NEAX2000 IVS2 Installation Procedure Manual
ND-70928 (E), Issue 1.0Page 25
PN-2ODTA ODT 2-line Out Band Dialling Trunk Card
Used as either a 2-wire E&M trunk or a 4-wire E&M trunk.
Equipped with –48V DC-DC on-board power supply.
Both No. 0 and No. 1 circuits must be set to the same pur-
pose (2-wire or 4-wire) in one card.
PN-2ODTB
[For N.Z.]ODT 2-line Out Band Dialling Trunk Card
Used as either a 2-wire E&M trunk or a 4-wire E&M trunk.
Equipped with –48V...

Page 52

CHAPTER 1 GENERAL INFORMATION
Line Conditions of Each Terminal
NEAX2000 IVS2 Installation Procedure ManualPage 26ND-70928 (E), Issue 1.0
LINE CONDITIONS OF EACH TERMINAL
The cable length between the DLC card and terminal varies depending on the type of terminal.
This table shows the line conditions of each D
term, DSS/BLF Console, and Attendant Console.
Table 1-6  Line Conditions of Each Terminal 
TERMINAL TYPE CARD TYPECABLE LENGTH*
(Cable 0.5
φ/24 AWG)REMARKS
Dterm75 (Series E)
(8...

Page 53

CHAPTER 1 GENERAL INFORMATION
Line Conditions of Each Terminal
NEAX2000 IVS2 Installation Procedure Manual
ND-70928 (E), Issue 1.0Page 27
Dterm65 (Series III)
(8 button)PN-8DLCL/8DLCP
(STANDARD)984 ft. (300 m)NOTE 1
PN-4DLCM/4DLCQ
(STANDARD)984 ft.
[3937 ft.(300 m)
(1200 m)]
PN-2DLCB/2DLCN
(LONG)2788 ft.
[3937 ft.(850 m)
(1200 m)]
D
term65 (Series III)
(24 button)PN-8DLCL/8DLCP
(STANDARD)492 ft. (150 m)NOTE 1
PN-4DLCM/4DLCQ
(STANDARD)492 ft.
[3937 ft.(150 m)
(1200 m)]
PN-2DLCB/2DLCN
(LONG)2788 ft.
[3937...

Page 54

CHAPTER 1 GENERAL INFORMATION
Line Conditions of Each Terminal
NEAX2000 IVS2 Installation Procedure ManualPage 28ND-70928 (E), Issue 1.0
NOTE 1:
When using PN-8DLCL or PN-8DLCP card, it is not available long line function, even
if D
term is equipped with Long Line Adapter.
NOTE 2:
The DSS/BLF Console requires local AC/DC power supply. SN708/709/712 
ATTCON
(2-wire type ATTCON)PN-8DLCL/8DLCP
(STANDARD)984 ft. (300 m)NOTE 1
PN-4DLCM/4DLCQ
(STANDARD)984 ft.
[3937 ft.(300 m)
(1200 m)]
PN-2DLCB/2DLCN...

Page 55

CHAPTER 1 GENERAL INFORMATION
Mounting Conditions of Circuit Card
NEAX2000 IVS2 Installation Procedure Manual
ND-70928 (E), Issue 1.0Page 29
MOUNTING CONDITIONS OF CIRCUIT CARD
This section explains the conditions for mounting circuit cards used in the system.
Circuit Card Mounting Slots
The figure below shows circuit card mounting slots allocated in the PIM based on circuit card
type.
Figure 1-7  Circuit Card Mounting Slots
*1
PZ-VM00-M card is to be mounted in LT00 slot to use VM slot.
*2
Either...

Page 56

CHAPTER 1 GENERAL INFORMATION
Circuit Card Mounting Slots
NEAX2000 IVS2 Installation Procedure ManualPage 30ND-70928 (E), Issue 1.0

Mountable slots according to the number of ports
The PIM can mount 8-port circuit cards. 
Available slots are defined by the number of ports of the circuit card.
*
In Slots 08-11, 8-port circuit cards are not mountable. The number of physical ports which 
can be provided by Slots 08-11 depends on the number of ports of the circuit cards mounted 
in Slots 04-07.
MOUNTING...

Page 57

CHAPTER 1 GENERAL INFORMATION
Control Card Mounting Conditions
NEAX2000 IVS2 Installation Procedure Manual
ND-70928 (E), Issue 1.0Page 31
Control Card Mounting Conditions
(1) PN-CP14 (MP)
Mount the PN-CP14 card in the MP slot (Slot 12) of PIM0.
(2) PN-CP15 (FP)
When the system is configured with three PIMs or more, mount one PN-CP15 card in the 
FP slot (PIM0: Slot 11, PIM2, 4, 6: Slot 12) of PIM0, PIM2, PIM4, and PIM6.
When the system is configured with one or two PIMs, the PN-CP15 card needs not to be...

Page 58

CHAPTER 1 GENERAL INFORMATION
Application Processor Card Mounting Conditions
NEAX2000 IVS2 Installation Procedure ManualPage 32ND-70928 (E), Issue 1.0
Application Processor Card Mounting Conditions
(1) System Capacity for Application Processor Card
Max. 24 cards per system
Max. 256 ports per system
(2) Mounting Application Processor Cards in PIM0
Use slots AP00 to AP11 to mount application processor cards in PIM0.
AP11 Slot (FP11 slot) of PIM0 is not available for application processor if the system is...

Page 59

CHAPTER 1 GENERAL INFORMATION
Application Processor Card Mounting Conditions
NEAX2000 IVS2 Installation Procedure Manual
ND-70928 (E), Issue 1.0Page 33
(3) Mounting Application Processor Cards in PIM1-7
Use Slots AP00 to AP11 to mount application processor cards in PIM1 through 7.
Figure 1-10  Application Processor Card Mounting Slots (PIM1-7)
*1
Application processor cards can be mounted in AP00 to AP11 slots.
AP09AP08AP07
LTC1LTC0LTC2
BWB
PIM
1 - 7
FRONTAC/DC
PWR...

Page 60

CHAPTER 1 GENERAL INFORMATION
Application Processor Card Mounting Conditions
NEAX2000 IVS2 Installation Procedure ManualPage 34ND-70928 (E), Issue 1.0
(4) Mounting Conditions of Each Card
CARD NAME MOUNTING CONDITIONS
PN-PW00 No circuit card can be mounted in the adjoining left side slot
because one card occupies two physical slots width.
PN-CC01 Mount the PN-CC01 card in the slot that adjoins the PN-AP01
card. Connect both cards using cable (48-TW-0.3 CONN CA).
PN-BRTA
PN-2BRTC
PN-24DTA-C
PN-30DTC-A...