Page 51
CHAPTER 1 GENERAL INFORMATION Line/Trunk Card NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 25 PN-2ODTA ODT 2-line Out Band Dialling Trunk Card Used as either a 2-wire E&M trunk or a 4-wire E&M trunk. Equipped with –48V DC-DC on-board power supply. Both No. 0 and No. 1 circuits must be set to the same pur- pose (2-wire or 4-wire) in one card. PN-2ODTB [For N.Z.]ODT 2-line Out Band Dialling Trunk Card Used as either a 2-wire E&M trunk or a 4-wire E&M trunk. Equipped with –48V...
Page 52
CHAPTER 1 GENERAL INFORMATION Line Conditions of Each Terminal NEAX2000 IVS2 Installation Procedure ManualPage 26ND-70928 (E), Issue 1.0 LINE CONDITIONS OF EACH TERMINAL The cable length between the DLC card and terminal varies depending on the type of terminal. This table shows the line conditions of each D term, DSS/BLF Console, and Attendant Console. Table 1-6 Line Conditions of Each Terminal TERMINAL TYPE CARD TYPECABLE LENGTH* (Cable 0.5 φ/24 AWG)REMARKS Dterm75 (Series E) (8...
Page 53
CHAPTER 1 GENERAL INFORMATION Line Conditions of Each Terminal NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 27 Dterm65 (Series III) (8 button)PN-8DLCL/8DLCP (STANDARD)984 ft. (300 m)NOTE 1 PN-4DLCM/4DLCQ (STANDARD)984 ft. [3937 ft.(300 m) (1200 m)] PN-2DLCB/2DLCN (LONG)2788 ft. [3937 ft.(850 m) (1200 m)] D term65 (Series III) (24 button)PN-8DLCL/8DLCP (STANDARD)492 ft. (150 m)NOTE 1 PN-4DLCM/4DLCQ (STANDARD)492 ft. [3937 ft.(150 m) (1200 m)] PN-2DLCB/2DLCN (LONG)2788 ft. [3937...
Page 54
CHAPTER 1 GENERAL INFORMATION Line Conditions of Each Terminal NEAX2000 IVS2 Installation Procedure ManualPage 28ND-70928 (E), Issue 1.0 NOTE 1: When using PN-8DLCL or PN-8DLCP card, it is not available long line function, even if D term is equipped with Long Line Adapter. NOTE 2: The DSS/BLF Console requires local AC/DC power supply. SN708/709/712 ATTCON (2-wire type ATTCON)PN-8DLCL/8DLCP (STANDARD)984 ft. (300 m)NOTE 1 PN-4DLCM/4DLCQ (STANDARD)984 ft. [3937 ft.(300 m) (1200 m)] PN-2DLCB/2DLCN...
Page 55
CHAPTER 1 GENERAL INFORMATION Mounting Conditions of Circuit Card NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 29 MOUNTING CONDITIONS OF CIRCUIT CARD This section explains the conditions for mounting circuit cards used in the system. Circuit Card Mounting Slots The figure below shows circuit card mounting slots allocated in the PIM based on circuit card type. Figure 1-7 Circuit Card Mounting Slots *1 PZ-VM00-M card is to be mounted in LT00 slot to use VM slot. *2 Either...
Page 56
CHAPTER 1 GENERAL INFORMATION Circuit Card Mounting Slots NEAX2000 IVS2 Installation Procedure ManualPage 30ND-70928 (E), Issue 1.0 Mountable slots according to the number of ports The PIM can mount 8-port circuit cards. Available slots are defined by the number of ports of the circuit card. * In Slots 08-11, 8-port circuit cards are not mountable. The number of physical ports which can be provided by Slots 08-11 depends on the number of ports of the circuit cards mounted in Slots 04-07. MOUNTING...
Page 57
CHAPTER 1 GENERAL INFORMATION Control Card Mounting Conditions NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 31 Control Card Mounting Conditions (1) PN-CP14 (MP) Mount the PN-CP14 card in the MP slot (Slot 12) of PIM0. (2) PN-CP15 (FP) When the system is configured with three PIMs or more, mount one PN-CP15 card in the FP slot (PIM0: Slot 11, PIM2, 4, 6: Slot 12) of PIM0, PIM2, PIM4, and PIM6. When the system is configured with one or two PIMs, the PN-CP15 card needs not to be...
Page 58
CHAPTER 1 GENERAL INFORMATION Application Processor Card Mounting Conditions NEAX2000 IVS2 Installation Procedure ManualPage 32ND-70928 (E), Issue 1.0 Application Processor Card Mounting Conditions (1) System Capacity for Application Processor Card Max. 24 cards per system Max. 256 ports per system (2) Mounting Application Processor Cards in PIM0 Use slots AP00 to AP11 to mount application processor cards in PIM0. AP11 Slot (FP11 slot) of PIM0 is not available for application processor if the system is...
Page 59
CHAPTER 1 GENERAL INFORMATION Application Processor Card Mounting Conditions NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 33 (3) Mounting Application Processor Cards in PIM1-7 Use Slots AP00 to AP11 to mount application processor cards in PIM1 through 7. Figure 1-10 Application Processor Card Mounting Slots (PIM1-7) *1 Application processor cards can be mounted in AP00 to AP11 slots. AP09AP08AP07 LTC1LTC0LTC2 BWB PIM 1 - 7 FRONTAC/DC PWR...
Page 60
CHAPTER 1 GENERAL INFORMATION Application Processor Card Mounting Conditions NEAX2000 IVS2 Installation Procedure ManualPage 34ND-70928 (E), Issue 1.0 (4) Mounting Conditions of Each Card CARD NAME MOUNTING CONDITIONS PN-PW00 No circuit card can be mounted in the adjoining left side slot because one card occupies two physical slots width. PN-CC01 Mount the PN-CC01 card in the slot that adjoins the PN-AP01 card. Connect both cards using cable (48-TW-0.3 CONN CA). PN-BRTA PN-2BRTC PN-24DTA-C PN-30DTC-A...