Home > NEC > Communications System > NEC Neax 2000 Ivs2 Ccis System Manual

NEC Neax 2000 Ivs2 Ccis System Manual

Here you can view all the pages of manual NEC Neax 2000 Ivs2 Ccis System Manual. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 261

 NEAX2000 IVS2 CCIS System ManualPage 248  ND-70918 (E), Issue 1.0
CHAPTER 3 SYSTEM DATA PROGRAMMING
Trunk to Trunk Restriction-CCIS
Programming
DESCRIPTION DATA
Assign the Trunk Restriction Class to the 
required trunk route.
(1)
(2)YY=97
00-63: Route No.
XZ
X: 1-8 : Day Class
Z: 1-8 : Night Class
1: Unrestricted (RCA)
2: Non-Restricted 1 (RCB)
3: Non-Restricted 2 (RCC)
4: Semi-Restricted 1 (RCE)
5: Semi-Restricted 2 (RCE)
6: Restricted 1 (RCF)
7: Restricted 2 (RCG)
8: Fully-Restricted (RCH)
Assign the...

Page 262

CHAPTER 3 SYSTEM DATA PROGRAMMING
Trunk to Trunk Restriction-CCIS
NEAX2000 IVS2 CCIS System Manual    
ND-70918 (E), Issue 1.0   Page 249
DESCRIPTION DATA
Assign the Toll Restriction Patterns with 
eight kinds of Trunk Restriction Classes 
assigned by CM35 YY=97. Toll Restriction 
Pattern 00-15 have already been 
programmed as shown below. If a new 
Restriction Pattern is required, change the 
data for Restriction Patterns 01-13 (00, 14 
and 15 are fixed).
(1)
(2)YY=01-13 
Toll Restriction Pattern No....

Page 263

 NEAX2000 IVS2 CCIS System ManualPage 250  ND-70918 (E), Issue 1.0
CHAPTER 3 SYSTEM DATA PROGRAMMING
Trunk to Trunk Restriction-CCIS
DESCRIPTION DATA
Assign the area code to be restricted and 
the Toll Restriction Pattern number 
assigned by CM81 to the Area Code 
Development Pattern number assigned by 
CM35 YY=76. For example, to provide the 
Trunk Restriction Class RCB, RCC, RCD, 
RCE, RCF, RCG and RCH with the Toll 
Restriction for Area Code “00”:
Area Code=00
Toll Restriction Pattern=05
(See Toll...

Page 264

CHAPTER 3 SYSTEM DATA PROGRAMMING
Trunk to Trunk Restriction-CCIS
NEAX2000 IVS2 CCIS System Manual    
ND-70918 (E), Issue 1.0   Page 251
DESCRIPTION DATA
To add the Tenant Pattern:
STEP 1 Assign the area code to be 
restricted and the Tenant 
Pattern number to the Area 
Code Development Pattern 
number assigned by CM35 
YY=76.
STEP 2  Assign the Tenant number and 
the Route Pattern number to 
Tenant Pattern number 
assigned by Step 1.
STEP 3  Assign the TR Pattern number 
to Route Pattern number...

Page 265

 NEAX2000 IVS2 CCIS System ManualPage 252  ND-70918 (E), Issue 1.0
CHAPTER 3 SYSTEM DATA PROGRAMMING
Trunk to Trunk Restriction-CCIS
DESCRIPTION DATA
STEP 3  Assign the starting time for the 
Toll Restriction and Route 
Pattern number to the Time 
Pattern number assigned by 
Step 2. Set the Starting Time as 
shown below.
Example:To Set the 7:00 AM to 9:00 PM 
for the Toll Restriction, enter the 
following starting times one by 
one.
0700 (7:00 AM-7:30 AM)
0730 (7:30 AM-8:00 AM)
0800 (8:00 AM-8:30 AM)...

Page 266

CHAPTER 3 SYSTEM DATA PROGRAMMING
Trunk to Trunk Restriction-CCIS
NEAX2000 IVS2 CCIS System Manual    
ND-70918 (E), Issue 1.0   Page 253
When changing the initial setting (See NOTE on next page.), or when receiving the IMX Trunk
Restriction Class (0-15), execute the following programming.
DESCRIPTION DATA
Assign the IMX Trunk Restriction Class to 
each PBX Trunk Restriction Class for the 
restriction class conversion from the PBX 
to IMX, if required.(1)
(2)20: TRK Restriction Class 1 (RCA)
21: TRK...

Page 267

 NEAX2000 IVS2 CCIS System ManualPage 254  ND-70918 (E), Issue 1.0
CHAPTER 3 SYSTEM DATA PROGRAMMING
Trunk to Trunk Restriction-CCIS
NOTE:If no data is set, the initial setting is shown below.
(1) PBX to IMX
(2) IMX to PBX
Operating Procedure
No manual operation is required.
1S T DATA 2ND DATA
20: TRK Restriction Class 1 (RCA)
21: TRK Restriction Class 2 (RCB)
22: TRK Restriction Class 3 (RCC)
23: TRK Restriction Class 4 (RCD)
24: TRK Restriction Class 5 (RCE)
25: TRK Restriction Class 6 (RCF)
26: TRK...

Page 268

CHAPTER 3 SYSTEM DATA PROGRAMMING
Uniform Numbering Plan-CCIS
NEAX2000 IVS2 CCIS System Manual    
ND-70918 (E), Issue 1.0   Page 255
UNIFORM NUMBERING PLAN-CCIS
General Description
In a CCIS network, a Uniform Numbering Plan enables a station user to call any other station in
the network. Two alternative numbering plans are provided. In the first plan, the station user dials
any digits station number from three to eight. The location of the office is identified by the first
one-, or two-digits of the...

Page 269

 NEAX2000 IVS2 CCIS System ManualPage 256  ND-70918 (E), Issue 1.0
CHAPTER 3 SYSTEM DATA PROGRAMMING
Voice Call-CCIS
VOICE CALL-CCIS
General Description
This feature provides a voice path, through the CCIS network, between a Dterm in one office and
a D
term in another office. This path is established from the calling party to the called party’s built-
in speaker. If the called party’s “MIC” is on, the called party can converse hands-free.
Programming
Operating Procedure
From a Dterm to another Dterm:
(1)...

Page 270

CHAPTER 3 SYSTEM DATA PROGRAMMING
Voice Mail Integration-CCIS
NEAX2000 IVS2 CCIS System Manual    
ND-70918 (E), Issue 1.0   Page 257
VOICE MAIL INTEGRATION-CCIS
General Description
This feature allows any station user in the CCIS network to utilize the Voice Mail System (VMS)
with the Message Center Interface (MCI).
Programming
Refer to Feature Programming Manual. 
Start reading NEC Neax 2000 Ivs2 Ccis System Manual

Related Manuals for NEC Neax 2000 Ivs2 Ccis System Manual

All NEC manuals