NEAX2000 IVS2 CCIS System ManualPage 268 ND-70918 (E), Issue 1.0 CHAPTER 4 CIRCUIT CARD INFORMATION PN-CP15 (FP) PN-CP15 (FP) Locations of Lamps, Switches, and Connectors Lamp Indications LAMP NAMECOLOR FUNCTION RUN Green Flashes at 120 IPM while the circuit card is operating normally. SENSE RUN MB SW1
Page 282
CHAPTER 4 CIRCUIT CARD INFORMATION PN-CP15 (FP) NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 269 Switch Settings The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. NOTE 1:Set the groove on the switch to the desired position. NOTE 2:When the power is on, flip the MB switch to ON...
Page 283
NEAX2000 IVS2 CCIS System ManualPage 270 ND-70918 (E), Issue 1.0 CHAPTER 4 CIRCUIT CARD INFORMATION PN-AP00-B (AP00) PN-AP00-B (AP00) Locations of Lamps, Switches, and Connectors CONN: To CONNR connector on PZ-M537 (EXPMEM) RS3 RS2 RS1 RS0 SENSE RUN MB SW0 SW2 L3 L2 L1 L0 SW1 CONN JP0 JP1
Page 284
CHAPTER 4 CIRCUIT CARD INFORMATION PN-AP00-B (AP00) NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 271 Lamp Indications Switch Settings LAMP NAMECOLOR FUNCTION RUN Green Flashes at 120 IPM while this card is operating normally. L0-L3 Green Second data setting value for CMD001 > 250 0 1 (Por t 0)-3 (Por t 2) L3 Indication of transmitting status of Port 0Indication of CTS signal status on Po r t 0 - 2 L2 Indication of transmitting status of Port 1Indication of DCD signal status...
Page 285
NEAX2000 IVS2 CCIS System ManualPage 272 ND-70918 (E), Issue 1.0 CHAPTER 4 CIRCUIT CARD INFORMATION PN-AP00-B (AP00) SW0 (Dip SW) 1-3 ONNot used For normal operation 4, 5 For normal operation OFFNot used 6 NOTE 3ONSets No. 0 Port forcibly in a state which DSR signal is always provided. OFFReceives DSR signal from the DCE on No. 0 Port. 7 NOTE 3ONSets No. 1 Port forcibly in a state which DSR signal is always provided. OFFReceives DSR signal from the DCE on No. 1 Port. 8 NOTE 3ONSets No. 2 Port...
Page 286
CHAPTER 4 CIRCUIT CARD INFORMATION PN-AP00-B (AP00) NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 273 SW2 (Dip SW) 1 NOTE 3ONSets No. 3 Port forcibly in a state which DSR signal is always provided. OFFReceives DSR signal from the DCE on No. 3 Port. 2ONEnables the receive clock from the DCE (Modem) when No. 1 Port is synchronous. (Clock is received at the RXC terminal) OFFUses internal clock as the receive clock when No. 1 Port is synchronous. When No. 1 Port is...
Page 287
NEAX2000 IVS2 CCIS System ManualPage 274 ND-70918 (E), Issue 1.0 CHAPTER 4 CIRCUIT CARD INFORMATION PN-AP00-B (AP00) The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. NOTE 1:Set the groove on the switch to the desired position. NOTE 2:When the power is on, flip the MB switch to ON (UP position) before...
Page 288
CHAPTER 4 CIRCUIT CARD INFORMATION PN-AP00-B (AP00) NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 275 NOTE 4:The use of the external clock (from the distant end) or the internal clock is determined by the following table: CLOCKSW2 26 External ON OFF Internal OFF ON
Page 289
NEAX2000 IVS2 CCIS System ManualPage 276 ND-70918 (E), Issue 1.0 CHAPTER 4 CIRCUIT CARD INFORMATION PN-24DTA-C (DTI) PN-24DTA-C (DTI) Locations of Lamps, Switches and Connectors SENSE RUN MB CRC PCM FRM RMT AIS BL SW1 SW0 JRR1 AISS MAS JPR0 JPS
Page 290
CHAPTER 4 CIRCUIT CARD INFORMATION PN-24DTA-C (DTI) NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 277 Lamp Indications LAMP NAMECOLOR FUNCTION RUN Green Flashes at 120 IPM while this card is operating normally. CRC Red Remains lit when detecting Cyclic Redundancy Checking (CRC) errors. PCM Red Remains lit when detecting PCM signal loss. FRM Red Remains lit when detecting Frame Alignment signal loss. RMT Red Remains lit when receiving Frame Alignment signal loss alarm from a...