NEC Neax 2000 Ivs2 Ccis System Manual
Here you can view all the pages of manual NEC Neax 2000 Ivs2 Ccis System Manual. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 291
NEAX2000 IVS2 CCIS System ManualPage 278 ND-70918 (E), Issue 1.0 CHAPTER 4 CIRCUIT CARD INFORMATION PN-24DTA-C (DTI) Switch Settings SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SENSE (Rotary SW) NOTE 10-3 Not used 4-F Set the switch to match the AP Number (04-31) to be set by CM05. MB (Toggle SW) NOTE 2 UP For make-busy For normal operation (Continued) F 4 AP No.SW1-4: ON04 05 06 07 08 09 10 11 12 13 14 15 SW1-4: OFF20 21 22 23 24 25 26 27 28 29 30 31 SW No.456789ABCDEF ON DOWN
Page 292
CHAPTER 4 CIRCUIT CARD INFORMATION PN-24DTA-C (DTI) NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 279 SW0 (Piano Key SW) 1 NOTE 3 NOTE 4ONSource clock signal from network is sent to the PLO 0 input on MP card. OFFSource clock signal from network is not sent to the PLO 0 input on MP card. 2 NOTE 3 NOTE 4ONSource clock signal from network is sent to the PLO 1 input on MP card. OFFSource clock signal from network is not sent to the PLO 1 input on MP card. 3ONRemote loop-back...
Page 293
NEAX2000 IVS2 CCIS System ManualPage 280 ND-70918 (E), Issue 1.0 CHAPTER 4 CIRCUIT CARD INFORMATION PN-24DTA-C (DTI) The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned.SW1 (Piano Key SW) NOTE 41 Not used 2 Not used 3 Not used 4ON AP No. 04-15 OFF AP No. 20-31 JPR0 (Jumper pin) UPNeutral grounding on the...
Page 294
CHAPTER 4 CIRCUIT CARD INFORMATION PN-24DTA-C (DTI) NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 281 NOTE 1:Set the groove on the switch to the desired position. NOTE 2:When the power is on, flip the MB switch to ON (UP position) before plugging/ unplugging the circuit card. NOTE 3:Set SW0-1 and SW0-2 as follows: NOTE 4:When the PBX is a clock source office, set the SW0-1 and SW0-2 on all the DTI cards mounted in PIM0 to “OFF”. NOTE 5:Mount the DTI card which receives a source...
Page 295
NEAX2000 IVS2 CCIS System ManualPage 282 ND-70918 (E), Issue 1.0 CHAPTER 4 CIRCUIT CARD INFORMATION PN-30DTC-A (DTI) PN-30DTC-A (DTI) Locations of Lamps, Switches and Connectors SENS RUN MB SW PCM FRM MFRM RMT MRMT AIS BL JP JPSJPR
Page 296
CHAPTER 4 CIRCUIT CARD INFORMATION PN-30DTC-A (DTI) NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 283 Lamp Indications LAMP NAMECOLOR FUNCTION RUN Green Flashes at 120 IPM when this card is normally operating. PCM Red Remains lit when detecting PCM signal loss. FRM Red Remains lit when detecting Frame Alignment signal loss. MFRM Red Remains lit when detecting Multi-Frame Alignment signal loss on time Slot 16. RMT Red Remains lit when receiving the alarm from a distant office...
Page 297
NEAX2000 IVS2 CCIS System ManualPage 284 ND-70918 (E), Issue 1.0 CHAPTER 4 CIRCUIT CARD INFORMATION PN-30DTC-A (DTI) Switch Settings SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SENS (Rotary SW) NOTE 14-FSet the switch to match the AP Number (04-31) to be set by CM05. 0-3Not used MB (Toggle SW) NOTE 2 UP For make-busy For normal operation (Continued) F 4AP No.SW-8: ON04 05 06 07 08 09 10 11 12 13 14 15 SW-8: OFF20 21 22 23 24 25 26 27 28 29 30 31 SW No.456789ABCDEF ON DOWN
Page 298
CHAPTER 4 CIRCUIT CARD INFORMATION PN-30DTC-A (DTI) NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 285 SW (Piano Key SW) 1 NOTE 3 NOTE 4ONSource clock signal from network is sent to the PLO 0 input on MP card. OFFSource clock signal from network is not sent to the PLO 0 input on MP card 2 NOTE 3 NOTE 4ONSource clock signal from network is sent to the PLO 1 input on MP card. OFFSource clock signal from network is not sent to the PLO 1 input on MP card. 3ON Remote loop-back For...
Page 299
NEAX2000 IVS2 CCIS System ManualPage 286 ND-70918 (E), Issue 1.0 CHAPTER 4 CIRCUIT CARD INFORMATION PN-30DTC-A (DTI) The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. NOTE 1:Set the groove on the switch to the desired position. NOTE 2:When the power is on, flip the MB switch to ON (UP position) before...
Page 300
CHAPTER 4 CIRCUIT CARD INFORMATION PN-30DTC-A (DTI) NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 287 NOTE 3:Set the SW-1 and SW-2 as follows: NOTE 4:When the PBX is a clock source office, set the SW-1 and SW-2 on all the DTI cards mounted in PIM0 to “OFF”. NOTE 5:Mount the DTI card which receives a source clock signal into PIM0. CONDITIONSDTI0 DTI1 DTI2 DTI3 REMARKS SW -1SW -2SW -1SW -2SW -1SW -2SW -1SW -2 When one DTI is provided.ON OFF––––––MP card will receive the clock signal...