Page 291

 NEAX2000 IVS2 CCIS System ManualPage 278  ND-70918 (E), Issue 1.0
CHAPTER 4 CIRCUIT CARD INFORMATION
PN-24DTA-C (DTI)
Switch Settings
SWITCH NAMESWITCH 
NUMBERSETTING 
POSITIONFUNCTION CHECK
SENSE
(Rotary SW)
NOTE 10-3 Not used
4-F Set the switch to match the AP Number (04-31) to 
be set by CM05.
MB (Toggle SW)
NOTE 2
UP For make-busy
For normal operation
(Continued)
F
4
AP No.SW1-4: ON04 05 06 07 08 09 10 11 12 13 14 15
SW1-4: OFF20 21 22 23 24 25 26 27 28 29 30 31
SW No.456789ABCDEF
ON
DOWN 

Page 292

CHAPTER 4 CIRCUIT CARD INFORMATION
PN-24DTA-C (DTI)
NEAX2000 IVS2 CCIS System Manual    
ND-70918 (E), Issue 1.0   Page 279
SW0
(Piano Key SW)
1
NOTE 3
NOTE 4ONSource clock signal from network is 
sent to the PLO 0 input on MP card.
OFFSource clock signal from network is 
not sent to the PLO 0 input on MP 
card. 
2 
NOTE 3
NOTE 4ONSource clock signal from network is 
sent to the PLO 1 input on MP card.
OFFSource clock signal from network is 
not sent to the PLO 1 input on MP 
card. 
3ONRemote loop-back...

Page 293

 NEAX2000 IVS2 CCIS System ManualPage 280  ND-70918 (E), Issue 1.0
CHAPTER 4 CIRCUIT CARD INFORMATION
PN-24DTA-C (DTI)
The figure in the SWITCH NAME column and the position in    in the SETTING POSITION
column indicate the standard setting of the switch. When the switch is not set as shown by the
figure and   , the setting of the switch varies with the system concerned.SW1
(Piano Key SW)
NOTE 41 Not used
2 Not used
3 Not used
4ON AP No. 04-15
OFF AP No. 20-31
JPR0 (Jumper pin)
UPNeutral grounding on the...

Page 294

CHAPTER 4 CIRCUIT CARD INFORMATION
PN-24DTA-C (DTI)
NEAX2000 IVS2 CCIS System Manual    
ND-70918 (E), Issue 1.0   Page 281
NOTE 1:Set the groove on the switch to the desired position.
NOTE 2:When the power is on, flip the MB switch to ON (UP position) before plugging/
unplugging the circuit card.
NOTE 3:Set SW0-1 and SW0-2 as follows:
NOTE 4:When the PBX is a clock source office, set the SW0-1 and SW0-2 on all the DTI cards
mounted in PIM0 to “OFF”.
NOTE 5:Mount the DTI card which receives a source...

Page 295

 NEAX2000 IVS2 CCIS System ManualPage 282  ND-70918 (E), Issue 1.0
CHAPTER 4 CIRCUIT CARD INFORMATION
PN-30DTC-A (DTI)
PN-30DTC-A (DTI)
Locations of Lamps, Switches and Connectors
SENS
RUN
MB
SW
PCM 
FRM 
MFRM 
RMT 
MRMT 
AIS 
BL  
 
 
 
 
JP JPSJPR 

Page 296

CHAPTER 4 CIRCUIT CARD INFORMATION
PN-30DTC-A (DTI)
NEAX2000 IVS2 CCIS System Manual    
ND-70918 (E), Issue 1.0   Page 283
Lamp Indications
LAMP 
NAMECOLOR FUNCTION
RUN Green Flashes at 120 IPM when this card is normally operating.
PCM Red Remains lit when detecting PCM signal loss.
FRM Red Remains lit when detecting Frame Alignment signal loss.
MFRM Red Remains lit when detecting Multi-Frame Alignment signal loss on 
time Slot 16.
RMT Red Remains lit when receiving the alarm from a distant office...

Page 297

 NEAX2000 IVS2 CCIS System ManualPage 284  ND-70918 (E), Issue 1.0
CHAPTER 4 CIRCUIT CARD INFORMATION
PN-30DTC-A (DTI)
Switch Settings
SWITCH
NAMESWITCH
NUMBERSETTING
POSITIONFUNCTION CHECK
SENS 
(Rotary SW)
NOTE 14-FSet the switch to match the AP Number (04-31) to 
be set by CM05.
0-3Not used
MB (Toggle SW)
NOTE 2
UP
For make-busy
For normal operation
(Continued)
F
4AP No.SW-8: ON04 05 06 07 08 09 10 11 12 13 14 15
SW-8: OFF20 21 22 23 24 25 26 27 28 29 30 31
SW No.456789ABCDEF
ON
DOWN 

Page 298

CHAPTER 4 CIRCUIT CARD INFORMATION
PN-30DTC-A (DTI)
NEAX2000 IVS2 CCIS System Manual    
ND-70918 (E), Issue 1.0   Page 285
SW
(Piano Key SW)
1
NOTE 3
NOTE 4ONSource clock signal from network is 
sent to the PLO 0 input on MP card.
OFFSource clock signal from network is 
not sent to the PLO 0 input on MP 
card 
2
NOTE 3
NOTE 4ONSource clock signal from network is 
sent to the PLO 1 input on MP card.
OFFSource clock signal from network is 
not sent to the PLO 1 input on MP 
card. 
3ON Remote loop-back
For...

Page 299

 NEAX2000 IVS2 CCIS System ManualPage 286  ND-70918 (E), Issue 1.0
CHAPTER 4 CIRCUIT CARD INFORMATION
PN-30DTC-A (DTI)
The figure in the SWITCH NAME column and the position in   in the SETTING POSITION
column indicate the standard setting of the switch. When the switch is not set as shown by the
figure and  , the setting of the switch varies with the system concerned.
NOTE 1:Set the groove on the switch to the desired position.
NOTE 2:When the power is on, flip the MB switch to ON (UP position) before...

Page 300

CHAPTER 4 CIRCUIT CARD INFORMATION
PN-30DTC-A (DTI)
NEAX2000 IVS2 CCIS System Manual    
ND-70918 (E), Issue 1.0   Page 287
NOTE 3:Set the SW-1 and SW-2 as follows:
NOTE 4:When the PBX is a clock source office, set the SW-1 and SW-2 on all the DTI cards
mounted in PIM0 to “OFF”.
NOTE 5:Mount the DTI card which receives a source clock signal into PIM0.
CONDITIONSDTI0 DTI1 DTI2 DTI3
REMARKS
SW
-1SW
-2SW
-1SW
-2SW
-1SW
-2SW
-1SW
-2
When one DTI is 
provided.ON OFF––––––MP card will receive the clock 
signal...